Monitor Application
This application manages local memory, providing access to peripherals and the GoodFET's global configuration.
Clients
All clients deal with the monitor.
Development
The monitor provides access to the local memory of the GoodFET device, and it ought to be used to
Verbs
The following verbs are supported.
| Hex | #define | Description |
|---|---|---|
| 0x02 | PEEK | Read word from memory at word[0]. |
| 0x03 | POKE | Write word[1] to memory at word[0]. (Not flash.) |
| 0x80 | CHANGE_BAUD | Change the baud rate. |
CHANGE_BAUD (0x80)
The GoodFET defaults to 9600 baud, but alternate baud rates are available by use of the CHANGE_BAUD (0x80) command of the Monitor application. This takes a single byte, which specifies the baud rate as per the following table.
This is the only command which does not generate a reply.
| Byte | Value |
|---|---|
| 0x00 | Default (9600) |
| 0x01 | 9600 |