1 00:00:00,042 --> 00:00:04,708 >>Thanks for skipping out of Kaminsky's talk and coming to see, see us, we really 2 00:00:04,708 --> 00:00:11,542 appreciate that. Um, just want to introduce ourselves quick. My name's Scott Erven, I do run a 3 00:00:11,542 --> 00:00:17,875 company called SecMedic and have been involved in IT security for just over 15 years, with a focus 4 00:00:17,875 --> 00:00:22,417 probably the last 3 years on medical devices and security so that's who I am. You want to hit 5 00:00:22,417 --> 00:00:27,542 me up on Twitter, you can try that or maybe get a hold of me after the talk and I'll give you 6 00:00:27,542 --> 00:00:32,292 contact info. >> Hi everyone. My name's Shawn Merdinger and I've been in security for about 7 00:00:32,292 --> 00:00:38,542 a little over a decade now. Worked at some big companies doing healthcare, I'm sorry, 8 00:00:38,542 --> 00:00:44,292 doing product security and then moved into some consulting and now I do healthcare and someone 9 00:00:44,292 --> 00:00:50,250 told me they were gonna save my spot at the summit party, so it's still, the line is still 10 00:00:50,250 --> 00:00:54,875 going, I think. (Laughter) So hopefully they'll hold it for me. God, I thought that would 11 00:00:54,875 --> 00:01:02,708 get a laugh! So I also run the MedSedic LinkedIn group which is on LinkedIn, it's got about 600 12 00:01:02,708 --> 00:01:07,958 folks. Anyone is welcome to join and then I have a little Twitter account here too which is 13 00:01:07,958 --> 00:01:13,958 focused on technical issues with medical devices and healthcare security in general. >> All 14 00:01:16,417 --> 00:01:20,417 right so first off we want to start with, you know, why we did we get involved in research in 15 00:01:20,417 --> 00:01:24,833 medical devices. Are we just assholes that want to call out people or do we really have a 16 00:01:24,833 --> 00:01:29,125 vested interest in this, in seeing that our products are more secure? So one of the big 17 00:01:29,125 --> 00:01:35,167 things for us, you know, we realize that healthcare industry is behind and this isn't just 18 00:01:35,167 --> 00:01:41,042 another Android bug when we get into these things. It really has patient safety consequences with 19 00:01:41,042 --> 00:01:46,042 these types of devices. They are made to save lives, and ultimately they do a very good 20 00:01:46,042 --> 00:01:51,708 job at that. But we think that security can get better, can improve. And so that's why we 21 00:01:51,708 --> 00:01:56,667 are looking into the research on that. And we also, we know there is a lot of healthcare 22 00:01:56,667 --> 00:02:01,833 organizations that this is kind of new to. As an industry healthcare security is quite a 23 00:02:01,833 --> 00:02:06,500 bit behind. We'll talk about that later. But we want to equip defenders especially in the 24 00:02:06,500 --> 00:02:13,000 healthcare space and make sure, you know, that they can protect those devices and ultimately if 25 00:02:13,000 --> 00:02:17,208 you look across, you know, any healthcare organization out there, I think if you are 26 00:02:17,208 --> 00:02:22,917 working for one, you're gonna find something inside of their missions and values, right? And 27 00:02:22,917 --> 00:02:29,792 this is what really got to me of how can I, you know, affect missions and values for 28 00:02:29,792 --> 00:02:34,875 healthcare organizations? And they're going to have something with, you know, patient safety, 29 00:02:34,875 --> 00:02:40,333 is going to be something, one of their critical missions, one of their critical values or core 30 00:02:40,333 --> 00:02:45,667 beliefs that they have. And so that really came to me is: How can I have a direct impact on 31 00:02:45,667 --> 00:02:49,458 that instead of sitting in the background, you know, as a security guy and kind of 32 00:02:49,458 --> 00:02:54,000 indirectly being able to help folks out on the floor deliver patient care? This is where we 33 00:02:54,000 --> 00:02:58,542 cross into, you know, IS security folks really having a direct contribution to that 34 00:02:58,542 --> 00:03:03,250 mission on patient safety for organizations. So it's kind of what we're doing, you know, why 35 00:03:03,250 --> 00:03:08,208 we do it. >> One thing I'd add, too, is I think we have a shared commonality too when it comes to 36 00:03:08,208 --> 00:03:15,167 healthcare and medical devices so no matter who you are, no matter how spooky you are, you 37 00:03:15,167 --> 00:03:19,875 know, what kind of surveillance you're doing or afraid of, we're all human, we all get sick, we 38 00:03:19,875 --> 00:03:26,167 all get people in need of healthcare and I think there is a truly shared commonality of, 39 00:03:26,167 --> 00:03:31,125 you know, when we check into a hospital, when we go to a clinic, no matter who you are, 40 00:03:31,125 --> 00:03:38,875 you want to make sure that that device has some integrity and that you can trust it. So real 41 00:03:38,875 --> 00:03:43,875 quick, I wanna get into some of the disclosure, too. We just want everyone to be aware that 42 00:03:43,875 --> 00:03:49,542 the stuff in our talk has been disclosed and we'll talk about some of the more detailed 43 00:03:49,542 --> 00:03:54,125 disclosure processes as we go along. This is kind of a high-level time line so as you 44 00:03:54,125 --> 00:03:59,333 can see, we are working really hard to push our research quickly and we are pushing 45 00:03:59,333 --> 00:04:03,625 really hard to get it out quickly to the community and especially the healthcare 46 00:04:03,625 --> 00:04:08,167 organizations that, and medical device manufacturers that can really make, you know, make a 47 00:04:08,167 --> 00:04:14,167 change here. So April 30th is when we went into this SMV finding disclosure that we're 48 00:04:16,375 --> 00:04:24,250 gonna talk about here. And that was the first time we disclosed this information at DHS. We had 49 00:04:24,250 --> 00:04:31,833 a detailed briefing with them about a week later. And then we went into after the SMV stuff we 50 00:04:31,833 --> 00:04:36,708 decided to look at direct, public-facing internet-exposed medical devices and 51 00:04:36,708 --> 00:04:43,500 infrastructure and some of those were then disclosed in May. So again it's really recent stuff 52 00:04:43,500 --> 00:04:47,958 we have been working hard to get the disclosure process, so we could talk to you about it. We 53 00:04:47,958 --> 00:04:52,792 have also been providing a lot of ongoing assistance to both federal organizations as well 54 00:04:52,792 --> 00:04:56,583 as, you know, healthcare organizations and manufacturers as we work through these things 55 00:04:56,583 --> 00:05:04,042 with them. So... >> So if you are looking for zero days, you are in the wrong room. So that's 56 00:05:04,042 --> 00:05:09,208 not how we do this. We try to be really responsible in all our disclosure and all of our 57 00:05:09,208 --> 00:05:12,875 communication with this. We don't want to put people at risk, there is already enough 58 00:05:12,875 --> 00:05:17,833 risk in these devices that you'll see as we get further in the talk. And that leads into 59 00:05:17,833 --> 00:05:25,042 many of these vulnerabilities are old, in many respects this is a new area, for medical 60 00:05:25,042 --> 00:05:29,667 device manufacturers, and this type of exposure because of the integration that's happenings 61 00:05:29,667 --> 00:05:36,792 across healthcare with EHRs, going all the way to the bedside, there's gonna be new 62 00:05:36,792 --> 00:05:43,458 pacs surfaces that emerge. So Scott did some really great work on threat modeling with uh, and 63 00:05:43,458 --> 00:05:50,208 he'll demonstrate how it's a very simple vulnerability was leveraged to impact potentially 64 00:05:50,208 --> 00:05:55,417 from an adversarial standpoint an entire organization, including their medical devices. 65 00:05:55,417 --> 00:05:59,750 So that should be a real wakeup call. I was a little scared about talking about that at 66 00:05:59,750 --> 00:06:06,958 first, more because it's such a low-level vulnerability but then he-- >> Woo-hoo! (Laughter) 67 00:06:06,958 --> 00:06:12,958 (Applause) >> Let's rock it! >> He--, I didn't even say cyberyet. (Laughter) Then, so 68 00:06:19,583 --> 00:06:24,250 the other thing is the medical device exposure from the public Internet. So as I mentioned more 69 00:06:24,250 --> 00:06:27,708 of these are coming online, there's greater integration and there are medical devices on the 70 00:06:27,708 --> 00:06:33,083 public Internet. We are trying to be responsible in disclosure but at the same time creating 71 00:06:33,083 --> 00:06:39,083 more pressure to an awareness of this, too. . >> All right. Taking a timeout here. >> 72 00:06:44,667 --> 00:06:50,667 Excuse me. (Pause) (Laughter) Raise your hand if you are a brand new speaker at DEF CON. 73 00:06:53,958 --> 00:07:01,250 >> Let's go! >> All right. Welcome for the new speaker! [Cheers and applause] >> All 74 00:07:01,250 --> 00:07:07,250 right. All right. Solid. >> God, that's just awful! (Laughter) >> So these 75 00:07:11,625 --> 00:07:17,625 external findings pose a significant risk -- (Laughter) -- >> I'll work this a little 76 00:07:19,667 --> 00:07:25,667 more. >> You guys are done! >> All right. Yeah, so what's the bad news here, right, in all the 77 00:07:29,333 --> 00:07:35,167 findings? The external findings we're gonna expose, you know, we think it is a significant risk, 78 00:07:35,167 --> 00:07:39,917 the patient safety. The medical devices, the supporting systems and technology that interface 79 00:07:39,917 --> 00:07:46,208 with these medical devices. The other bad news is most of these we found within 30 minutes to an 80 00:07:46,208 --> 00:07:51,833 hour, so you know I'm not up here to tell you I'm some elite hacker or anything like that, 81 00:07:51,833 --> 00:07:55,708 there's much smarter people in this audience and we'll get into how you can help, you know, get 82 00:07:55,708 --> 00:08:01,458 into this area later but it was very simple things we did and threat modeling that we did here 83 00:08:01,458 --> 00:08:07,000 but they are definitely significant threats to patient safety. They also provide 84 00:08:07,000 --> 00:08:12,208 support, the healthcare industry is very far behind other industries, typical of what we 85 00:08:12,208 --> 00:08:16,167 see in, you know, financial or retail sector which they are getting breached every week as 86 00:08:16,167 --> 00:08:20,833 well so there's not much difference but it's not just your bank account. It is, you 87 00:08:20,833 --> 00:08:27,375 know, patient safety issues here that are affected. I think in our work, you know, one of the 88 00:08:27,375 --> 00:08:34,542 things that is coming to light, and you know the folks over at the agency, DHS and ICS will 89 00:08:34,542 --> 00:08:40,542 probably start to tell you now, we always thought industrial control systems and that whole 90 00:08:43,375 --> 00:08:48,250 industry was quite a ways behind what we are seeing. But I think it's safe to say now and with 91 00:08:48,250 --> 00:08:51,958 the research that we're showing, that the healthcare industry is probably five years behind what 92 00:08:51,958 --> 00:08:56,333 that is. So it's definitely a good ten years, we've got a lot of catchup to do and we probably 93 00:08:56,333 --> 00:09:00,000 need to do it fairly quickly with some of the mobile health and digital health stuff that's 94 00:09:00,000 --> 00:09:03,333 coming on the horizon which we'll touch on later, but. That's definitely some of the 95 00:09:03,333 --> 00:09:09,292 bad news. So let Shawn cover the good stuff. He can be the good guy. >> Yeah, for once. You 96 00:09:09,292 --> 00:09:14,542 know, one thing I'd add, too, with the, it's almost like a lost decade going on here, so, 97 00:09:14,542 --> 00:09:21,000 with medical devices. And also healthcare security folks are amongst the lowest paid in the 98 00:09:21,000 --> 00:09:26,375 industry so that vertical itself, which is I think will actually change in the coming 99 00:09:26,375 --> 00:09:29,958 years, because there's going to be more breaches and there's going to be more specialized 100 00:09:29,958 --> 00:09:36,042 expertise which is needed with these devices. So, yeah, there is good news. The external risk 101 00:09:36,042 --> 00:09:43,292 can be mitigated using your existing infrastructure in many cases so you want to follow 102 00:09:43,292 --> 00:09:49,750 those hardening guidelines that are put out by like MIST and other organizations and CSI, 103 00:09:49,750 --> 00:09:55,708 right, too? Didn't we talk about that? CIS, rather. >> Yeah, CSI is a TV show. (Laughter) >> 104 00:09:55,708 --> 00:10:03,042 Thank you, I'm really not a drinker so this is already getting to me! Damn goons! >> 105 00:10:03,042 --> 00:10:10,625 So, yeah, CIS, you know, they've reached out. I think we'll talk about it a little bit later. >> 106 00:10:10,625 --> 00:10:18,042 Ok, yeah, we'll do that. >> Bear with me. (Speaking off-mic). >> So just a show of 107 00:10:18,042 --> 00:10:23,958 hands here: Who has heard of SHODAN? Oh, that's good. That's encouraging. So, you know, 108 00:10:23,958 --> 00:10:30,042 SHODAN was one of the main tools that we used in this and that's a tool you can leverage in your 109 00:10:30,042 --> 00:10:37,917 own organization and John Matherly, props out to him, this is his project and so, you know, 110 00:10:37,917 --> 00:10:43,250 with using those types of tools, you can discover what types of exposure you have on your 111 00:10:43,250 --> 00:10:49,833 external network and then you can start doing that mitigation. >> All right, so I just want to 112 00:10:49,833 --> 00:10:56,125 touch kinda quickly before we get into, you know, some of the new stuff here, on, you know, 113 00:10:56,125 --> 00:11:01,042 previous research, more so, you know, previous device exposure, you know, across platforms, the 114 00:11:01,042 --> 00:11:07,375 type of things that we see, the types of issues in these types of devices, so first is kind of 115 00:11:07,375 --> 00:11:14,583 lab and refrigeration systems. So that environment -- and a lot of these, they are not unique to 116 00:11:14,583 --> 00:11:20,208 a vendor so there is no value in saying, oh it was this vendor or it was that vendor, it's really 117 00:11:20,208 --> 00:11:26,083 across platforms. It's a systemic issue, it's not, you know, one versus the other here. 118 00:11:26,083 --> 00:11:30,208 So we'll talk about them generically and kind of give you some architectural background 119 00:11:30,208 --> 00:11:34,375 into how these things function, where the flaws are in these devices where an attacker could 120 00:11:34,375 --> 00:11:39,292 potentially, you know, cause patient safety issues. So refrigeration storage, these are 121 00:11:39,292 --> 00:11:45,250 anything from, you know, storing just blood inside the laboratory all the way up to like full 122 00:11:45,250 --> 00:11:52,542 cryogenic like freezer levels. The types of issues we see on these are they have unencrypted 123 00:11:52,542 --> 00:11:57,333 web services and they have hard-coded credentials. So the lab techs inside the healthcare 124 00:11:57,333 --> 00:12:00,958 organization, they'll actually carry, most times, sometimes they'll throw it in their desk, 125 00:12:00,958 --> 00:12:06,333 but usually they'll carry pagers that are set up to alert them if there is like a upper or a lower 126 00:12:06,333 --> 00:12:12,167 limit on these devices that gets tripped. So if it loses power and the temperature drops they 127 00:12:12,167 --> 00:12:15,250 get alerted so that they can go respond and they can throw it into another, you know, 128 00:12:15,250 --> 00:12:20,000 refrigeration system. Well through these web interfaces, which either have no 129 00:12:20,000 --> 00:12:25,583 authentication into them or they very weak credentials into them, you can go into those types of 130 00:12:25,583 --> 00:12:29,458 systems and you can alter things. So first you can turn off alerting or change the 131 00:12:29,458 --> 00:12:34,250 alerting to those pager systems. Secondly you can change upper and lower limits on the 132 00:12:34,250 --> 00:12:38,125 temperature controls. You can even shut these units off. So those are the type of risks 133 00:12:38,125 --> 00:12:43,583 there, you know, spoilage, things like that, that you get into with those devices. Pacs 134 00:12:43,583 --> 00:12:48,917 imaging. You know, that's not really a patient safety issue too much but this is where 135 00:12:48,917 --> 00:12:53,708 you're seeing when you get into like the PHI stuff, not necessarily patient safety, but 136 00:12:53,708 --> 00:12:58,750 this is where I feel a lot of the exploitation of actual patient documentation is coming 137 00:12:58,750 --> 00:13:02,667 out of healthcare organizations. All but one vendor that I researched on the paces imaging 138 00:13:02,667 --> 00:13:08,208 side, how they operate is through an application, through that pacs application they call 139 00:13:08,208 --> 00:13:14,333 back-in storage for those imaging systems. Through the application they actually prompt 140 00:13:14,333 --> 00:13:19,125 and they use authentication and they call it and they log if you've accessed that PHI. The 141 00:13:19,125 --> 00:13:23,583 back-end storage unfortunately happens to be in all but one case that I've looked at 142 00:13:23,583 --> 00:13:28,458 completely unauthenticated access into the Nas device or the storage network where all of 143 00:13:28,458 --> 00:13:34,375 those, you know, patient records and images, and, you know, PHI type information. So that's a 144 00:13:34,375 --> 00:13:38,542 big one. I think we'll loop this Pacs thing back in later when we start talking about some more 145 00:13:38,542 --> 00:13:43,000 exposure and how I believe, you know, a lot of our data is being leaked out very easily outside 146 00:13:43,000 --> 00:13:47,917 of healthcare organizations to sell people's medical identities. >> MRI and CT 147 00:13:47,917 --> 00:13:55,375 systems, you get into like nuke med systems as well, these are interesting. They pretty much 148 00:13:55,375 --> 00:14:01,833 function similar across the board when you get into CT, MRI systems. If you look at all the 149 00:14:01,833 --> 00:14:07,417 documentation you'll find that there isn't a whole lot of difference on them. Nuke med 150 00:14:07,417 --> 00:14:10,875 machines, they actually have work stations that directly talk to it but when you get into the 151 00:14:10,875 --> 00:14:15,542 radiology space, the MRI, the CT, that's when the RAD tech is actually sitting in the room 152 00:14:15,542 --> 00:14:20,875 behind the, you know, behind the enclosure and how those operate is obviously the physician 153 00:14:20,875 --> 00:14:26,542 orders what imaging they want, and they program that order into the application and that 154 00:14:26,542 --> 00:14:31,042 actually gets sent down to like the CT system. And so it kinda sits there in like a holding 155 00:14:31,042 --> 00:14:37,208 pattern. It almost functions like a queue inside those devices. But unfortunately they 156 00:14:37,208 --> 00:14:41,083 use unencrypted web traffic as well so you can man in the middle that traffic, you can, 157 00:14:41,083 --> 00:14:45,500 you know, alter those types of things. They do have a failsafe which is actually really good in 158 00:14:45,500 --> 00:14:49,708 most cases. Like the nuke meds are direct and they don't function like that but that's 159 00:14:49,708 --> 00:14:54,958 not real radiation exposure. But MRI and CTs, they kinda have like a Staples Easy button over 160 00:14:54,958 --> 00:14:58,958 at the side where the Rad tech actually has to, you know, manually kind of hit and then it 161 00:14:58,958 --> 00:15:03,875 goes out to the work station and takes that queue and then processes that image. But 162 00:15:03,875 --> 00:15:08,625 because it's unencrypted and you can man in the middle of it, you can alter what's actually going 163 00:15:08,625 --> 00:15:13,625 on in there when they actually execute that. Defibrillators, this one's an interesting one, 164 00:15:13,625 --> 00:15:19,083 when you get into ICD technology, if any of you know who Kevin Fu is, he did a lot of 165 00:15:19,083 --> 00:15:26,083 great work, he actually documented it out. And most of these, they run, they run on 166 00:15:26,083 --> 00:15:31,667 telemetry so they run at like a 400k range. The problem with these is the pacemaker 167 00:15:31,667 --> 00:15:36,417 controller systems, if you access those, they don't require authentication. And once you 168 00:15:36,417 --> 00:15:41,208 associate it to the implantable defib, you can issue the command and it will reprogram, it will 169 00:15:41,208 --> 00:15:46,500 set upper and lower sensing limits for the device on, you know, when to start shocking, 170 00:15:46,500 --> 00:15:51,000 you know, when to stop, when to sense, you know, when there's a cardiac event. And so those 171 00:15:51,000 --> 00:15:55,167 things you can also Man in the Middle. I think Kevin Fu, if you are really interested in the 172 00:15:55,167 --> 00:16:00,250 details of that, he did a great job, you know, look it up. Take a look at his research all the 173 00:16:00,250 --> 00:16:04,500 way back to 2008. There is obviously a clinical need for that, too, and I will bring that 174 00:16:04,500 --> 00:16:09,667 up and that's one of the challenges that you get into this space is you know you would 175 00:16:09,667 --> 00:16:14,000 hate for a patient to show up and, oh, I forgot the passcode in order to, you know, deliver a 176 00:16:14,000 --> 00:16:17,375 shot. I have to reprogram this device. So that's the flip side of it. It's definitely, you 177 00:16:17,375 --> 00:16:22,833 know, a challenging area. Externals? I'm not gonna talk too much about those, we have a 178 00:16:22,833 --> 00:16:27,583 very detailed case example of a specific manufacturer on external cardiac defib that 179 00:16:27,583 --> 00:16:34,708 we're gonna release today. >> It's awesome! (Laughter) >> And infusion pumps. These are 180 00:16:34,708 --> 00:16:39,792 ones that they have web interfaces on them, oftentimes, you know, no authentication or 181 00:16:39,792 --> 00:16:46,542 weak credentials, they also have accessible services. Medical device integration, this is an 182 00:16:46,542 --> 00:16:52,125 interesting one. So historically, you know, some of the very critical, life-saving 183 00:16:52,125 --> 00:16:56,792 medical devices that were out there. So ventilators, anesthesia carts, things like 184 00:16:56,792 --> 00:17:01,500 that, they historically and for a reason, weren't ever networked, right? So they just 185 00:17:01,500 --> 00:17:07,500 did serial interfaces and things like that; they weren't put on a network. Well, Affordable Care 186 00:17:10,958 --> 00:17:14,500 Act and things like that, and having to pump all this data to a centralized location in order 187 00:17:14,500 --> 00:17:17,333 to do BigData analytics on healthcare populations we have decided that we needed to 188 00:17:17,333 --> 00:17:23,042 integrate life support equipment so we have gone with medical device integration vendors, a 189 00:17:23,042 --> 00:17:26,833 lot of healthcare organizations are doing this now and it's bringing in these critical 190 00:17:26,833 --> 00:17:30,792 devices onto the network, reading those vital signs and then ultimately transferring 191 00:17:30,792 --> 00:17:35,750 off. Again completely unencrypted. No encryption. You can Man in the Middle that. You 192 00:17:35,750 --> 00:17:40,500 can actually replay it. They do use unique identifiers but you can correlate it all the way 193 00:17:40,500 --> 00:17:47,250 through from the unique identifier back to the patient. Whoops. >> So these are pretty 194 00:17:47,250 --> 00:17:53,375 much the top risks that we've identified so far. Just across these systems and again there's 195 00:17:53,375 --> 00:17:58,542 nothing terribly sexy about this, right? We've seen this for years. A hard-coded privileged 196 00:17:58,542 --> 00:18:05,208 accounts. It never goes away. It's gonna be here forever. Unencrypted web apps and then 197 00:18:05,208 --> 00:18:10,750 all kinds of API calls and then back-end services like Scott mentioned earlier with the Pacs 198 00:18:10,750 --> 00:18:16,708 systems going to the storage interfaces. And then, you know, many of these systems are built 199 00:18:16,708 --> 00:18:20,333 off of COTS equipment, so they're just using medical device manufacturers, they're 200 00:18:20,333 --> 00:18:26,333 using your standard, maybe an embedded Windows or VX works or a Windows 2003 or 2008 server-- 201 00:18:29,542 --> 00:18:35,542 >> XP or 2000. We'll kind of touch on that as we go through examples too. (Speaking 202 00:18:40,417 --> 00:18:47,375 off-mic). >> Yeah, or embedded. All over, yeah. Right. So they're not OS experts and 203 00:18:47,375 --> 00:18:51,750 typically they are not removing the excessive services that are on these operating systems and 204 00:18:51,750 --> 00:18:56,250 then there's the patching. So we'll talk about the patching issues more but there's a real 205 00:18:56,250 --> 00:19:00,583 misconception out there about there about hey you can't patch medical devices and that is just 206 00:19:00,583 --> 00:19:06,667 is not true. The FDA, there's no F.B.I. here, right, they weren't invited so-- (Laughter) 207 00:19:06,667 --> 00:19:12,250 -- The FDA has issued guidance for the past ten years indicating that yes, you can 208 00:19:12,250 --> 00:19:16,167 patch medical devices. But we'll get into that later about, you know, how you do that or should 209 00:19:16,167 --> 00:19:22,542 you do that or what are the risks associated with that. >> Yeah so that's kind of the, you 210 00:19:22,542 --> 00:19:30,042 know, first round of research, kind of dabbled into for the last few years. And we were 211 00:19:30,042 --> 00:19:38,000 going to kinda stop there. But there was a lot of outreach to that and a lot of refutal of, 212 00:19:38,000 --> 00:19:45,458 you know, points that yes, you know, you found these issues in medical devices but they are in 213 00:19:45,458 --> 00:19:51,833 internal networks, they're fire-walled off from everything else. Well, you know I called BS 214 00:19:51,833 --> 00:19:58,500 on that. It's definitely not how it is. And so I think we wanted to show that, you know, the 215 00:19:58,500 --> 00:20:03,458 public was really unaware, I think, and even a lot of IS staff, inside of healthcare 216 00:20:03,458 --> 00:20:08,583 organizations, were really unaware of this risk, and they truly believed that all their 217 00:20:08,583 --> 00:20:12,000 devices were fire-walled off, that you couldn't access them directly from the Internet. 218 00:20:12,000 --> 00:20:19,083 This is a blurb from a private industry notice, note that I'm not throwing off a private 219 00:20:19,083 --> 00:20:23,458 industry notice, this was off Google and the media got a hold of it so don't think I'm 220 00:20:23,458 --> 00:20:28,292 throwing out one of the F.B.I.'s hints to you guys but this is a, you know, a good quote that kind 221 00:20:28,292 --> 00:20:33,208 of shows the biggest vulnerability was the perception of IT professionals healthcare 222 00:20:33,208 --> 00:20:37,000 beliefs that their current perimeter defense and compliance strategy are working when 223 00:20:37,000 --> 00:20:42,625 clearly the data states otherwise. So that is kind of, I mean, that's on an F.B.I. pin, 224 00:20:42,625 --> 00:20:47,333 so they probably should start listening, it's just not some, you know, guy named Scott up 225 00:20:47,333 --> 00:20:51,083 there telling you. >> And respect to the F.B.I. for doing that. I mean, for stepping up, 226 00:20:51,083 --> 00:20:55,208 because if you really, you know, cut to the chase, this is almost kind of out of their purview 227 00:20:55,208 --> 00:21:01,000 until it gets into a criminal matter, you know, I'm not a lawyer but, you know, this is 228 00:21:01,000 --> 00:21:06,917 getting into the FDA and you know, HHS and so who has oversight of these issues? So 229 00:21:06,917 --> 00:21:12,083 it's great to see that the F.B.I. is talking about this and raising awareness. >> Yeah and 230 00:21:12,083 --> 00:21:16,250 physicians as well. I think there needs to be more awareness on that end across healthcare 231 00:21:16,250 --> 00:21:20,208 organizations, a lot of systems get brought in from the physicians for clinical care. 232 00:21:20,208 --> 00:21:26,000 Security is an afterthought of that decision that's been made and so we'll talk again a little 233 00:21:26,000 --> 00:21:30,333 further on, you know, some involvement I have had now with, you know, physicians in 234 00:21:30,333 --> 00:21:36,125 collaboration which is great and we need to, you know, bring that awareness up, all the physicians 235 00:21:36,125 --> 00:21:40,625 I talk to, they care, they just don't know. >> I think really that's where we're gonna see the 236 00:21:40,625 --> 00:21:44,833 rubber meet the road as far as physicians, you know. They are the ones handling and taking 237 00:21:44,833 --> 00:21:49,625 care of patients directly. They are tremendously respected not only in the community but within 238 00:21:49,625 --> 00:21:55,208 the organizations and they have a lot of power. There were MD students who were giving talks 239 00:21:55,208 --> 00:21:59,958 at this conference, we are developing relationships with them, we are seeing in academic 240 00:21:59,958 --> 00:22:05,750 medical centers an entire new generation of tech-savvy physicians getting trained so we 241 00:22:05,750 --> 00:22:10,000 need to bring these people into the fold and explain the risks to them and then get them on our 242 00:22:10,000 --> 00:22:16,000 side. >> You take this one, Shawn. You're following this awesome quote. 22:21>> So 243 00:22:19,833 --> 00:22:24,667 everyone knows who Avi Rubin is, right? I mean he's a well-respected researcher, 244 00:22:24,667 --> 00:22:28,708 Independent Security Evaluators , I think he's the president there, he's definitely one of 245 00:22:28,708 --> 00:22:33,542 the founders. And I just thought this was a wonderful quote. And, you know, I have never seen an 246 00:22:33,542 --> 00:22:37,250 industry with more gaping holes, if our financial industry, with regard to security the way 247 00:22:37,250 --> 00:22:44,250 healthcare does, I would stuff my cash in a mattress under my bed. >> Yeah, so that says a 248 00:22:44,250 --> 00:22:49,333 whole lot, I think. >> And that was in 2012, right, yeah, 12/25. >> Yeah, that was a couple 249 00:22:49,333 --> 00:22:54,250 years ago. All right. So let's get into, like, first round of some of the exposure when we 250 00:22:54,250 --> 00:23:00,583 started to look at Internet-facing devices, direct from Internet public IP. So we 251 00:23:00,583 --> 00:23:05,625 started to research that, right, and we were doing some, you know, custom really elite 252 00:23:05,625 --> 00:23:09,667 searches, like, for key words like anesthesia that no one would ever think of -- 253 00:23:09,667 --> 00:23:15,667 (Laughter) -- and we happened to right away within 30 minutes, we came across something that I 254 00:23:18,958 --> 00:23:25,417 clearly knew wasn't an anesthesia work station itself. But we realized very quickly 255 00:23:25,417 --> 00:23:31,875 that it had SMV open and I know who cares about SMV? I didn't come to hear DEF CON talk about 256 00:23:31,875 --> 00:23:35,625 SMV just being open but I think the threat modeling that we're gonna show you is really where 257 00:23:35,625 --> 00:23:42,500 that risk is and the information that we could extract related to medical devices and supporting 258 00:23:42,500 --> 00:23:48,417 systems inside of the healthcare organization. >> So this was Scott's finding and we have been 259 00:23:48,417 --> 00:23:52,750 exchanging phone calls while we're doing these searches and I'm sure those are archived 260 00:23:52,750 --> 00:23:59,417 somewhere and perhaps someday we'll listen to them but yeah it was amazing, it was amazing to 261 00:23:59,417 --> 00:24:03,875 see this. Because he was like, dude, send me this search -- he's like, did that finish 262 00:24:03,875 --> 00:24:08,208 downloading yet of off SHODAN? I'm like, no, no, that still hasn't finished downloading, so 263 00:24:08,208 --> 00:24:12,500 this is the results page of what, you know, the system is showing us. Like, no, no, so I 264 00:24:12,500 --> 00:24:17,875 had to jump on a VPS server that has like a 10 gig or 10 meg pipeline and you know, pull it 265 00:24:17,875 --> 00:24:25,500 down and got a quick page count and it was like, you know, 1482 pages. >> Just that one of the 266 00:24:25,500 --> 00:24:30,958 thousands of organizations that you talk about here. >> Yeah, but this was one box off of one 267 00:24:30,958 --> 00:24:36,792 organization with one port open. So it just shows, goes to show that wow, just one exposure. >> 268 00:24:36,792 --> 00:24:40,500 So here is a little bit more information on the initial healthcare organization 269 00:24:40,500 --> 00:24:45,500 discovery. This was the first one we found. I found it probably like 10:30 at night and 270 00:24:45,500 --> 00:24:51,958 was calling DHS at like midnight saying, hey, you know, we got an issue here, took the day off the 271 00:24:51,958 --> 00:24:56,958 next day and worked all day to find out, you know, was it just an issue with one organization 272 00:24:56,958 --> 00:25:01,000 or was it really, you know, a systemic issue across healthcare, you know, and the 273 00:25:01,000 --> 00:25:05,500 hundreds and thousands of healthcare organizations were wide open externally? Well, 274 00:25:05,500 --> 00:25:11,458 turned out to be even though we're using one example, the first example that we found, you 275 00:25:11,458 --> 00:25:15,583 know, it's not just one organization's issue. It is across the world in many 276 00:25:15,583 --> 00:25:19,833 instances and we will show you the statistics that we have on that. But to give you an idea 277 00:25:19,833 --> 00:25:25,708 of size it was a very large U.S. healthcare system. They had over 12,000 employees, 3,000 278 00:25:25,708 --> 00:25:30,417 physicians and you'll see when we get into the actual medical devices and the systems that 279 00:25:30,417 --> 00:25:34,792 communicate with these medical devices, they did have a large cardiovascular neuroscience 280 00:25:34,792 --> 00:25:41,833 institutions attached to those. It exposed intelligence. When we dump that 1500-page document 281 00:25:41,833 --> 00:25:46,583 after we finally got it downloaded and extracted all the raw data, it was over 68,000 282 00:25:46,583 --> 00:25:52,958 systems provided a direct attack vector from externally anywhere in the world, public IP, into 283 00:25:52,958 --> 00:25:58,542 those systems. Full control if an attacker wanted it. It also exposed one of the things that 284 00:25:58,542 --> 00:26:03,917 we found that, again, isn't, you know, unique to this organization. It's across the 285 00:26:03,917 --> 00:26:07,833 thing, is we've seen indicators of, you know, third party organizations that were 286 00:26:07,833 --> 00:26:12,083 connected and contracted for certain services so, you know, specialty services, things like 287 00:26:12,083 --> 00:26:18,542 that, that are contracted out by other organizations. We have seen those systems and, you 288 00:26:18,542 --> 00:26:22,625 know, names used that were affiliated with those systems inside of there. So it wasn't 289 00:26:22,625 --> 00:26:26,958 just these organizations had an issue; they were also exposing third party connections and 290 00:26:26,958 --> 00:26:32,083 security issues there as well. >> And ene thing, too, this also exposed a lot of your 291 00:26:32,083 --> 00:26:39,083 internal business operations so HR systems, payroll, what we traditionally think of, of an 292 00:26:39,083 --> 00:26:44,292 attack vector and what attackers were going for. Interestingly, we were looking for healthcare 293 00:26:44,292 --> 00:26:50,083 and medical exposure here so there was PHRs and all that but it was, yeah, it was 294 00:26:50,083 --> 00:26:55,750 disconcerting to see all that business process systems exposure as well. >> Yeah, so I 295 00:26:55,750 --> 00:26:58,667 think that's a good point. 'Cause it definitely wasn't, you know, our focus was on, you 296 00:26:58,667 --> 00:27:02,875 know, medical devices, healthcare infrastructure, things on patient safety but 297 00:27:02,875 --> 00:27:06,583 this was, you know, these 68,000 systems weren't just medical devices. It was their entire 298 00:27:06,583 --> 00:27:11,250 infrastructure and so we can give you an example on all those medical devices and supporting 299 00:27:11,250 --> 00:27:15,250 systems that we found but we also, if we were into talking about that could've shown you 300 00:27:15,250 --> 00:27:19,375 just as many examples with financial systems, payroll systems, you know, employee-type 301 00:27:19,375 --> 00:27:25,250 confidential information as well. >> So again, you know, did we find only one? No, you 302 00:27:25,250 --> 00:27:28,542 know, we found hundreds. When you link them together, when you change the search term, so you 303 00:27:28,542 --> 00:27:34,542 can see right here this is a screenshot inside of SHODAN, but what we're doing is, so you can 304 00:27:37,167 --> 00:27:42,750 see the hits, so we are just doing searches and then we're using key words that would be 305 00:27:42,750 --> 00:27:46,542 associated with medical facilities. So health stocks, any type of like healthcare 306 00:27:46,542 --> 00:27:49,833 system that has that in their organization name. Clinic, hospital and medical and you can 307 00:27:49,833 --> 00:27:53,500 see the number of hits that have this exposure. Well when you change that into, you know, 308 00:27:53,500 --> 00:27:57,500 specialty things, like if you change that search term to like cardiology, or radiology, or 309 00:27:57,500 --> 00:28:02,750 urology, or pediatrics or something like that, you're gonna get all the organizations 310 00:28:02,750 --> 00:28:07,375 that have that inside their org name, and then when you tie those into the third parties 311 00:28:07,375 --> 00:28:12,667 that were affected inside of those disclosures you end up with, you know, thousands of 312 00:28:12,667 --> 00:28:16,375 healthcare systems that are really affected. >> So what's key to think about is, you know, 313 00:28:16,375 --> 00:28:21,875 there is a lot of specialty small clinics so when we have gone out and maybe got an MRI, 314 00:28:21,875 --> 00:28:26,583 you've got sent to a special, small specialty clinic, and these are all, you know, tied in 315 00:28:26,583 --> 00:28:31,750 with the healthcare systems, too, and you know, the kinds of searches we did here, with just 316 00:28:31,750 --> 00:28:36,417 the org name, if you are looking for, you know, specific clinics you can do those types of 317 00:28:36,417 --> 00:28:42,542 searches too, and really get granular, even by geographic areas. So SHODAN is a very very 318 00:28:42,542 --> 00:28:48,667 powerful tool, it's not the only tool to use this but it was, it was, it fit our needs and what 319 00:28:48,667 --> 00:28:54,708 we wanted to show at the time. >> And so here's some heat maps. And if you haven't checked 320 00:28:54,708 --> 00:29:00,667 out SHODAN lately we had access to the beta thanks to John, and we actually have been able to 321 00:29:00,667 --> 00:29:05,000 work with him to do custom searches for certain ports that aren't publicly available just 322 00:29:05,000 --> 00:29:10,125 to dig into a little bit more specific medical device exposure across the Internet but these 323 00:29:10,125 --> 00:29:13,500 are some new heat maps that he came out with so definitely go in and, you know, check this 324 00:29:13,500 --> 00:29:18,167 out. It's kind of a neat feature. It will not only show you the heat map overlay but it 325 00:29:18,167 --> 00:29:24,375 will also show you top affected domain names, organizations across the world. So this is 326 00:29:24,375 --> 00:29:29,667 just some heat maps for key words of what we did and kind of the concentrations for high host 327 00:29:29,667 --> 00:29:36,125 down to low host count. You will see kind of a theme here that it is U.S.centric, I don't know how 328 00:29:36,125 --> 00:29:39,458 to spell health insurance in Chinese if they put that in their org name or things like 329 00:29:39,458 --> 00:29:44,750 that so I don't know if that has to do with some of the disparate information or not but the U.S. 330 00:29:44,750 --> 00:29:50,958 definitely is a big red dot on all this stuff, so. This is one for the clinic, as you can see. 331 00:29:50,958 --> 00:29:57,417 U.S. is still definitely top on the list for organizations that have this issue. Same with 332 00:29:57,417 --> 00:30:02,125 hospital. And here is the heat map for medical. It starts getting a little more 333 00:30:02,125 --> 00:30:08,125 interesting, China and stuff starts getting big and red. One thing we did do is we don't 334 00:30:10,333 --> 00:30:13,625 cover it in the talk but I'll just talk about it, you know, quickly is some of this 335 00:30:13,625 --> 00:30:17,875 customized stuff that we're doing with SHODAN, and that was just released as well, is X 11, 336 00:30:17,875 --> 00:30:23,208 so if you want to go and search like Port 6,000 X 11, we did that with John and he just 337 00:30:23,208 --> 00:30:28,708 released it publicly. So there's a lot of unauthenticated X 11 devices. We weren't able to 338 00:30:28,708 --> 00:30:32,458 correlate it back to medical devices so we are not talking about it but he has released it. 339 00:30:32,458 --> 00:30:36,542 There's like 60,000 systems out there, 30,000 of which are completely unauthenticated 340 00:30:36,542 --> 00:30:43,708 across the Internet. So who cares about SMV again? You know, why did we skip Dan Kaminsky's 341 00:30:43,708 --> 00:30:49,083 talk to come watch a bunch of posers talk about SMV, right? But that's not it. It's really 342 00:30:49,083 --> 00:30:55,708 the threat model here. And why does this matter? You know, who cares? Well, this system and 343 00:30:55,708 --> 00:31:01,708 others like it also happen to be Windows XP. And it's vulnerable to MS08-067 and for those of you 344 00:31:05,292 --> 00:31:09,417 that weren't in the security industry back then, that is you know the exploit or the 345 00:31:09,417 --> 00:31:14,500 vulnerability that can configure utilized. So this is old. This is from 2008. Still have 346 00:31:14,500 --> 00:31:20,917 external-facing systems running SMV. Also you can pop that box direct. So this is kind of a 347 00:31:20,917 --> 00:31:25,375 host profile, the OS, just a screen cap, obviously the information is hidden on this 348 00:31:25,375 --> 00:31:30,375 organization. >> And I pushed back against Scott on this, too, when he first brought it to me. 349 00:31:30,375 --> 00:31:35,250 I was like this really isn't that interesting. Once we started looking more into the 350 00:31:35,250 --> 00:31:40,125 full exposure of this organization and he painted the picture for me then it became 351 00:31:40,125 --> 00:31:45,917 much clearer, and so that's what is -- >> Yup, I think that's what is coming here. So why does 352 00:31:45,917 --> 00:31:51,333 it matter and what, I'm gonna show you here in the next slide why does it matter. Well the SMV 353 00:31:51,333 --> 00:31:57,042 as we know, it by design is gonna leak host names. Well who really cares about host names 354 00:31:57,042 --> 00:32:03,167 necessarily? But what we also realized with these healthcare organizations is that not only 355 00:32:03,167 --> 00:32:08,542 was SMV open but read access, anonymous read access to their Active Directory infrastructure 356 00:32:08,542 --> 00:32:11,875 was also pulling through directly to the internet and exposing all this detailed 357 00:32:11,875 --> 00:32:17,083 information that allowed us to identify, you know, specific medical devices, not just 358 00:32:17,083 --> 00:32:21,417 medical devices themselves, but the supporting technology systems and applications. And I 359 00:32:21,417 --> 00:32:26,875 want to, I want to clarify on that. Everyone talks to medical devices and a lot of people may 360 00:32:26,875 --> 00:32:32,333 think that it's just, you know, implantables or just the actual device itself. You know, the CT 361 00:32:32,333 --> 00:32:37,042 scan or the MRI system. The actual infusion pump. But understand it's a large 362 00:32:37,042 --> 00:32:42,417 ecosystem here. No longer is it just stand-alone systems. So those work stations that they 363 00:32:42,417 --> 00:32:46,667 are using, they interact and they have the application that issues instructions to the 364 00:32:46,667 --> 00:32:51,042 medical device, to the patient. So that's why, you know, all these work stations and things 365 00:32:51,042 --> 00:32:55,042 like that are so important. 'Cause they do have direct access to communicate with the 366 00:32:55,042 --> 00:33:01,208 medical devices through the application. So leaked out host names. And it oftentimes leaked 367 00:33:01,208 --> 00:33:06,458 out very specific information that attacker could use. So we'll show you some examples in 368 00:33:06,458 --> 00:33:13,667 here of, you know, the floor, the office, physician names are in here. And also AD policy was 369 00:33:13,667 --> 00:33:19,625 applied so like the ORs, by design most healthcare organizations set timeouts on 370 00:33:19,625 --> 00:33:26,250 ORs. >> Who are they? >> Yeah. And, you know, the reason they do that is 'cause they're all 371 00:33:26,250 --> 00:33:30,125 scrubbed up, right. I mean that's the, you know, the reason they don't want to be messing 372 00:33:30,125 --> 00:33:36,125 around with big clunky gloves having to unlock it. You'll see some examples here that shows us 373 00:33:38,417 --> 00:33:45,250 that the specific systems also have timeout exemptions in place. So let's get into, you 374 00:33:45,250 --> 00:33:48,958 know, what other systems we found, show some examples here. Why does this matter. Let's 375 00:33:48,958 --> 00:33:54,333 paint a picture of why, you know, it's not just SMV but it's really a threat model here. So 376 00:33:54,333 --> 00:33:59,542 over on the left you can see those are the systems with the lockout exemptions, so that is 377 00:33:59,542 --> 00:34:06,042 something where we know that the screensaver time out isn't gonna kick in so that matters, right, 378 00:34:06,042 --> 00:34:10,708 so especially in like a physical attack scenario that we get into later, that matters because you 379 00:34:10,708 --> 00:34:16,083 want to know what system has a timeout exemption. Over on the right, here's this customer 380 00:34:16,083 --> 00:34:20,833 happened to use Epic, please note again this isn't a manufacturer issue. This is just 381 00:34:20,833 --> 00:34:25,208 the organization and all these organizations had a misconfiguration. So this isn't 382 00:34:25,208 --> 00:34:29,500 anything that Epic or a manufacturer can fix themselves but this is just an example. You 383 00:34:29,500 --> 00:34:34,333 can see all their servers here, these are used for everything from the SQL server back end all 384 00:34:34,333 --> 00:34:39,958 the way into web servers, I believe down there towards the bottom, MyChart, MyChart is if 385 00:34:39,958 --> 00:34:45,375 anyone here goes as a patient to a healthcare organization and they use Epic, MyChart is your 386 00:34:45,375 --> 00:34:51,292 portal into all of your medical record data. So that's this organization's server. We now 387 00:34:51,292 --> 00:34:57,583 know we can hit it directly from the net. All right. Let's talk about a little bit more stuff. 388 00:34:57,583 --> 00:35:02,750 So pacs imaging. We talked about those previously. We have seen through our research that they 389 00:35:02,750 --> 00:35:07,000 don't require on the back end authentication or the one manufacturer I have ran across 390 00:35:07,000 --> 00:35:12,875 that does, the little kids over in Roots could probably crack in about three minutes, so it's not 391 00:35:12,875 --> 00:35:19,625 very difficult. So here is radiology systems. Here is the CT system. Pacs, you know, CT3 392 00:35:19,625 --> 00:35:25,458 right there. So that's some of the radiology stuff. Down at the bottom, telemetry. There's a 393 00:35:25,458 --> 00:35:31,125 couple use cases for telemetry systems. We can't tell exactly just off this what exactly that 394 00:35:31,125 --> 00:35:35,417 device is for. We can only profile on this case. So telemetry can be used for 395 00:35:35,417 --> 00:35:40,750 different things. It can be used for infant induction systems or wandering adult patients, those 396 00:35:40,750 --> 00:35:47,083 types of things. They use a little armband to alert, you know, if the mother, if the 397 00:35:47,083 --> 00:35:53,125 child are too far apart or if one gets taken off the unit. Telemetry is also obviously used 398 00:35:53,125 --> 00:35:57,000 and we'll show you some examples of this, for pacemakers, pacemaker controller type 399 00:35:57,000 --> 00:36:03,000 systems. Speaking of pacemakers, here are some pacemakers and we also had specific examples that 400 00:36:05,708 --> 00:36:12,250 were very labeled as pacemaker controller. So we know that those were the pacemaker 401 00:36:12,250 --> 00:36:16,917 controller systems inside of an organization. We know that those pacemaker controller systems 402 00:36:16,917 --> 00:36:23,333 don't require any type of authentication to communicate once they have associated to a 403 00:36:23,333 --> 00:36:28,625 implantable. You can also see here, we have scrubbed it but there's an example in here, of 404 00:36:28,625 --> 00:36:33,208 you can see doctor or whatever that is and you can see those types of examples. Specifically 405 00:36:33,208 --> 00:36:39,292 where they are at. Second one there, there is pediatrics. Nuclear medicine. Down at the 406 00:36:39,292 --> 00:36:44,042 bottom, this is when you get into anesthesia, right. Anesthesia OR, we know that this 407 00:36:44,042 --> 00:36:50,083 is an anesthesia work station. The OR environment is very controlled so thinking that you 408 00:36:50,083 --> 00:36:55,750 would have anesthesia OR labeled separate from the anesthesia work station that is directly 409 00:36:55,750 --> 00:37:00,042 attached to the anesthesia cart, there is just no way, this is definitely an anesthesia work 410 00:37:00,042 --> 00:37:04,583 station that is on the anaesthesia cart inside of the OR. You could hit it directly 411 00:37:04,583 --> 00:37:11,667 from the internet. So we found a few of these devices, right, you're giving us some examples, 412 00:37:11,667 --> 00:37:15,333 you're showing us some screenshots, types of devices that you found. Well, we 413 00:37:15,333 --> 00:37:21,000 didn't. We took that big log for this specific organization of the thousands that we found, we 414 00:37:21,000 --> 00:37:27,292 dumped out the raw data and we started to extract that data and we identified thousands of, you 415 00:37:27,292 --> 00:37:34,542 know, the medical devices and those supporting systems and those applications. So we used 416 00:37:34,542 --> 00:37:41,750 our favorite data extraction tool called Excel 'cause we're really sophisticated. >> He 417 00:37:41,750 --> 00:37:47,667 did. I haven't gotten my Excel certification yet! (Laughter) >> Yeah. So this is a overview. 418 00:37:47,667 --> 00:37:52,667 So we took all that raw data, we dumped it to Excel and then basically what we did is we just 419 00:37:52,667 --> 00:37:56,750 did a search and a find for key words on these types of devices. So we did a search for 420 00:37:56,750 --> 00:38:01,625 anesthesia. There was 21 systems that were affiliated with anesthesia outside, inside this 421 00:38:01,625 --> 00:38:07,250 organization. Cardiology, 488. Like I said before, they had a very large cardiology 422 00:38:07,250 --> 00:38:13,000 institution and a nuclear medicine, nuke med, neurology institution as well. Infusion 423 00:38:13,000 --> 00:38:19,000 systems, found 133 systems. MRIs, 97. The Pacs systems, 323. So I think right here again it 424 00:38:22,833 --> 00:38:28,875 goes to the point that I don't know, maybe healthcare security is lax enough and poor enough 425 00:38:28,875 --> 00:38:33,917 right now that the attackers, you know, are not using this simple attack method to get in 426 00:38:33,917 --> 00:38:38,208 and get information on the devices, maybe they are just plastering everybody and they 427 00:38:38,208 --> 00:38:43,042 are able to go completely undetected. But if not they could do a little bit of 428 00:38:43,042 --> 00:38:47,833 research and they could find out, hey, just this one healthcare organization has 323 429 00:38:47,833 --> 00:38:54,958 you know, devices associated to Pacs and imaging in some way or another. Nuke med systems, 67, 430 00:38:54,958 --> 00:39:00,958 and ultimately on the cardiology side 31 systems associated to pacemakers. So potential 431 00:39:06,042 --> 00:39:11,833 attacks in this scenario. Threat modeling for this SMV exposure that leaks all of this 432 00:39:11,833 --> 00:39:17,417 information, right. We've got a few of those. The lamest one but still a viable option is, you 433 00:39:17,417 --> 00:39:21,208 know, physical attack. We now know a lot of information, we know what types of systems they 434 00:39:21,208 --> 00:39:27,083 are as a attacker. We know what types of medical device they are associated to. We know the 435 00:39:27,083 --> 00:39:31,500 healthcare organization and the location, we know the floor and the office number in lots of 436 00:39:31,500 --> 00:39:35,917 cases like I showed you and we know if that system has a lockout exemption. So we can now 437 00:39:35,917 --> 00:39:40,917 very strategically, right, Shawn, we can walk in and kind of pinpoint, we want to go to 438 00:39:40,917 --> 00:39:45,375 this floor, this office number, we know it's a cardiology doc that's seeing this patient, we 439 00:39:45,375 --> 00:39:49,250 want to go walk in, we know it's got a timeout exemption, we can probably sit down and never have 440 00:39:49,250 --> 00:39:53,750 to put in a password and get access to that system. >> And when it comes to healthcare 441 00:39:53,750 --> 00:39:58,000 organizations, you know, it's not like walking into a finance institution, financial 442 00:39:58,000 --> 00:40:02,375 institution where they're like a beady-eyed banker looking at you like you're gonna take his 443 00:40:02,375 --> 00:40:06,417 money. Healthcare organizations, you walk in there and there's people at the desk, hi, how can 444 00:40:06,417 --> 00:40:11,292 I help you, right? So they are very susceptible to a number of physical types of attacks. Plus 445 00:40:11,292 --> 00:40:16,708 you throw a lab coat on, put a stethoscope around your neck, you print up a badge, which you 446 00:40:16,708 --> 00:40:20,500 know, you can just easily do just from trolling the halls and looking to see what they look 447 00:40:20,500 --> 00:40:25,167 like, you know, it really opens up a scary avenue of attack because nobody really thinks 448 00:40:25,167 --> 00:40:31,875 about this. >> So what's the next one that we can kind of look at for an attack in this 449 00:40:31,875 --> 00:40:35,458 scenario on these organizations? Obviously a phishing attack, we're all very familiar with 450 00:40:35,458 --> 00:40:38,792 that, right? Agn, we know what systems they are we want to target. We know the healthcare 451 00:40:38,792 --> 00:40:43,000 organization, we know employee names, and so we can just start extracting email addresses for 452 00:40:43,000 --> 00:40:48,375 those employees. You know, that's very simple to do. And we know the host name and that's 453 00:40:48,375 --> 00:40:52,292 the key thing. We know the host name and we know what type of device it is. So we can write 454 00:40:52,292 --> 00:40:57,125 customized payload now that we can deliver through a phishing attack that once it's executed 455 00:40:57,125 --> 00:41:02,625 and once we have control on that internal system or even from that external-facing system that 456 00:41:02,625 --> 00:41:09,875 had MS08-067, we can directly pivot to only hit the devices that we want to hit. So an 457 00:41:09,875 --> 00:41:14,500 attacker can be very strategic with this type of information, right. They don't have to, you 458 00:41:14,500 --> 00:41:17,917 know, get a foothold and then scan the entire network and figure this out and be really 459 00:41:17,917 --> 00:41:23,125 noisy. They don't have to do that. They can simply send a phishing attack and then target 460 00:41:23,125 --> 00:41:27,875 directly toward those medical devices. Pivot attack, this is obviously external for those 461 00:41:27,875 --> 00:41:32,917 systems that had vulnerabilities. MS08-067 is just one of them. A lot of them 462 00:41:32,917 --> 00:41:38,333 are running vulnerable versions. IIS 6 that are sitting out there plus a lot of extra excessive 463 00:41:38,333 --> 00:41:44,125 services that are vulnerable as well. We also know in this pivot attack that's touching the 464 00:41:44,125 --> 00:41:47,792 back end network because it's leaking all the data for everyone of their things. It's 465 00:41:47,792 --> 00:41:52,792 also giving us read access in the active directory. So we know there is a hole and that there's 466 00:41:52,792 --> 00:41:57,292 a hop and that it's not firewalled off. So again we can create a custom payload directly 467 00:41:57,292 --> 00:42:04,833 and pivot internally. Targeted attack, this one is, you know, where you start to make the case 468 00:42:04,833 --> 00:42:11,292 for a targeted attack against a targeted patient, those types of scenarios, right. We can use the 469 00:42:11,292 --> 00:42:18,042 information we got over SMV so we know the systems that are associated. We also now know 470 00:42:18,042 --> 00:42:23,083 every single name of every one of their medical record servers, so all we have to do is 471 00:42:23,083 --> 00:42:27,583 strategically target those specific systems once we have a foothold in the network. So then 472 00:42:27,583 --> 00:42:31,375 an attacker can take that, attack the medical record, get a weak password, get a 473 00:42:31,375 --> 00:42:35,833 vulnerability and some legacy application and we can start correlating where the patients 474 00:42:35,833 --> 00:42:39,750 are gonna be when, and correlate that with the SMV data of where these devices are located and 475 00:42:39,750 --> 00:42:46,833 what type of devices they are, and then, you know, launch an attack. So, what's the good 476 00:42:46,833 --> 00:42:51,292 news out of this? I just want to touch on this example of healthcare organization. This 477 00:42:51,292 --> 00:42:57,292 was very positive. This is new space DHS and ICS-CERT did coordinate disclosure and with 478 00:43:00,500 --> 00:43:06,208 this healthcare organization among others that we used in our example, they did schedule a 479 00:43:06,208 --> 00:43:12,000 follow-up call. And so I did talk with healthcare organization and DHS. They 480 00:43:12,000 --> 00:43:19,417 actually, it was a very positive exchange. So typically we are dealing as security researchers, 481 00:43:19,417 --> 00:43:23,292 we are oftentimes dealing with manufacturers, right, and we're starting to get over those 482 00:43:23,292 --> 00:43:26,792 bounds as well, but initially, and the first time with everything, you know, there's a 483 00:43:26,792 --> 00:43:30,750 lot of legal land mines and pit falls that you gotta get through. So this was a big win 484 00:43:30,750 --> 00:43:36,292 for us, this is something that, you know, I'm proud of. This is the first time, you know, DHS 485 00:43:36,292 --> 00:43:39,292 says they've actually worked with a security researcher and an actual healthcare 486 00:43:39,292 --> 00:43:43,667 organization to expose these risks and work through it. They did -- (Inaudible) -- they 487 00:43:43,667 --> 00:43:47,875 showed good faith. I'm not gonna speak to what it contains but they did actually share their 488 00:43:47,875 --> 00:43:52,500 full incident response with me and I went through that with that organization so it was a 489 00:43:52,500 --> 00:43:57,167 very positive win overall in that interaction so I want to call that out. So next Shawn's 490 00:43:57,167 --> 00:44:03,167 going to talk on public Internet facing systems and is there any device that directly is on the 491 00:44:05,792 --> 00:44:11,042 net? >>I should have stayed over there. I liked it much better. So that was the first 492 00:44:11,042 --> 00:44:15,875 part. Kind of our talk here of the SMV exposure and just bear in mind we focused on one 493 00:44:15,875 --> 00:44:21,208 organization but we could have done this with a number of organizations. But just for the 494 00:44:21,208 --> 00:44:27,333 brevity and the exposure we just did that one. So medical devices on public Internet. I mean you 495 00:44:27,333 --> 00:44:31,583 really wouldn't think this is the case, you know. So a public IP address and then you have 496 00:44:31,583 --> 00:44:37,375 this medical device here, but it is and some of these are by design and on purpose. And what 497 00:44:37,375 --> 00:44:43,750 really makes this tricky is that some are using cellular modems so, and the reason is they may 498 00:44:43,750 --> 00:44:49,333 be remote clinics or they want to separate that in some ways from the other infrastructure, 499 00:44:49,333 --> 00:44:54,375 but what that does for, you know, ethical researchers who want to track down these devices 500 00:44:54,375 --> 00:44:59,417 and then ssociate that with the healthcare organization, it makes this very difficult for us 501 00:44:59,417 --> 00:45:05,417 to do that. So that's really where we need to reach out, you know, to the carriers and the 502 00:45:07,958 --> 00:45:15,250 FDA and HHS and even law enforcement because they have the capability to correlate 503 00:45:15,250 --> 00:45:22,375 those cellular modem addresses and IPs to these medical devices. So this is just four 504 00:45:22,375 --> 00:45:27,833 examples that we focused on of what we found out there. And I mean hese are publicly 505 00:45:27,833 --> 00:45:33,000 accessible on public IP, defibrillators and those, Scott's gonna really give you an 506 00:45:33,000 --> 00:45:40,000 excellent case study about that later on. They're deployed in ambulances and then these fetal 507 00:45:40,000 --> 00:45:45,167 infant monitoring systems which, if you follow any of my SHODAN talks over the past few years 508 00:45:45,167 --> 00:45:50,583 I've been yammering about, I'll get into more of those. EEG systems, so those are hooked up 509 00:45:50,583 --> 00:45:55,417 to folks at home and then they're tied into a cellular modem. And then of course Pacs 510 00:45:55,417 --> 00:45:59,667 and imaging systems, now the really the interesting thing about Pacs systems is when they 511 00:45:59,667 --> 00:46:04,833 take these MRI images of you, they are gigantic files so there's a storage back end, we 512 00:46:04,833 --> 00:46:09,500 talked about that, but then transferring them is an issue too. And then what's going on is 513 00:46:09,500 --> 00:46:14,750 there's consolidation in the industry of analysts who are specialized in doing this type 514 00:46:14,750 --> 00:46:21,167 of analysis. So there may be someone working across the country from home and doing all 515 00:46:21,167 --> 00:46:28,000 day long, you know, she's just looking at these images and then doing the analysis, writing up 516 00:46:28,000 --> 00:46:32,500 the report and sending that back to the healthcare organization. So it makes it much easier, 517 00:46:32,500 --> 00:46:38,958 right, to just stick this out on public IP. They can access it directly over a web interface. 518 00:46:38,958 --> 00:46:44,375 You don't have to allocate a VPN session to them. They are not choking up your bandwidth and 519 00:46:44,375 --> 00:46:49,500 that kind of thing. More traditional hardware infrastructure that we found 520 00:46:49,500 --> 00:46:56,000 exposed was just your old unauthenticated and misconfigured Cisco devices and 521 00:46:56,000 --> 00:47:03,000 edge routers and these have been known for years. They are really easy to find. And then also like 522 00:47:03,000 --> 00:47:06,958 device manufacturer infrastructure and then, you know, these third party contract 523 00:47:06,958 --> 00:47:11,750 organizations. What I mean by that and Scott's gonna talk a little bit about this, too, if 524 00:47:11,750 --> 00:47:16,625 you want. But what I mean about that is, hospitals are tremendously complex 525 00:47:16,625 --> 00:47:20,958 organizations. So, you know, just because there's a device on a hospital or a healthcare 526 00:47:20,958 --> 00:47:25,833 network doesn't necessarily mean they even own it. They may not even know about it. And when you 527 00:47:25,833 --> 00:47:32,333 get into like academic medical research centers you may have a professor who is also a 528 00:47:32,333 --> 00:47:37,000 physician, so and then they have somebody they are doing a research project on and then 529 00:47:37,000 --> 00:47:43,000 they got this device and then they allocate it to a public IP. So, you know, the IT folks may 530 00:47:43,000 --> 00:47:48,500 not know about it. The security folks typically will not know about it at all. And so these 531 00:47:48,500 --> 00:47:53,583 things just show up on the network. You have something to say on this? >> Yeah, I think 532 00:47:53,583 --> 00:47:57,875 in the healthcare systems too, understand, the one that we found, the one that we disclosed 533 00:47:57,875 --> 00:48:03,417 to DHS, this wasn't a small family clinic, this was a very large healthcare organization. 534 00:48:03,417 --> 00:48:09,000 It was not the same organization as the other example but it was very large, they had over 13,000 535 00:48:09,000 --> 00:48:12,875 employees just to give you some idea of size of the organization. So it wasn't a 536 00:48:12,875 --> 00:48:17,667 small thing. Completely on/off edge router just sitting out on the net, all their 537 00:48:17,667 --> 00:48:23,500 infrastructure was exposed. A lot of the manufacturer's side, what we've seen and is 538 00:48:23,500 --> 00:48:29,583 accessible, a lot of those that we found aren't necessarily you know the fault of the 539 00:48:29,583 --> 00:48:35,833 manufacturer; it's really implementation issues at the location but some of those come 540 00:48:35,833 --> 00:48:41,042 back to poor documentation or guidelines from the manufacturer. We see some 541 00:48:41,042 --> 00:48:45,958 documentation out there that is straight up for support reasons. In their documentation it tells 542 00:48:45,958 --> 00:48:50,542 you open every single port on the firewall for remote connectivity from these vendors 543 00:48:50,542 --> 00:48:55,875 which obviously is a little reckless. Not sure how they are QA'g those documents, it's 544 00:48:55,875 --> 00:49:02,417 obviously not needed and some folks are doing it. >> So we got a few case studies that 545 00:49:02,417 --> 00:49:07,667 we're gonna walk through. And this was the first reported medical device, meaning reported 546 00:49:07,667 --> 00:49:13,292 to ICS-CERT. And I found this in late 2012 and it was a Roche glucose meter. So this is a 547 00:49:13,292 --> 00:49:19,333 portable glucose meter to take blood sugar measurements and it has this base station on there. 548 00:49:19,333 --> 00:49:23,417 And the base station just had Telnet running but there was authentication required for it 549 00:49:23,417 --> 00:49:28,625 but Telnet, I mean it's clear textbook protocol. The vendor response was awesome, hat tip to 550 00:49:28,625 --> 00:49:36,042 the Roche guys, they were all over this, good communication, and then really good DHS and ICS 551 00:49:36,042 --> 00:49:41,667 response on this, too. This really gets more troubling. And I alluded to the Pacs systems 552 00:49:41,667 --> 00:49:47,708 before and the reason why these are exposed online and there are hundreds, and even if you start 553 00:49:47,708 --> 00:49:54,000 doing different versions, really thousands of them, and this is just the Kodak ones. And so, 554 00:49:54,000 --> 00:49:59,083 you know, Scott talked about the ecosystem before, right. So it's easy just to think, oh the 555 00:49:59,083 --> 00:50:03,083 stand-alone medical device, and what are the risks associated with it? But there's a whole 556 00:50:03,083 --> 00:50:07,500 client infrastructure that comes along with this and how do your clients communicate with it? 557 00:50:07,500 --> 00:50:14,917 And if you see here it's required to use Internet Explorer 6.0. On this system. 558 00:50:14,917 --> 00:50:18,542 >> Yeah, that's not that uncommon either by the way! >> So it's not that uncommon but 559 00:50:18,542 --> 00:50:22,708 then you think about these systems and okay are they dedicating that box, you know, 560 00:50:22,708 --> 00:50:29,250 and that client browser just for that system? Or is whomever is using this gonna jump online and 561 00:50:29,250 --> 00:50:35,750 start looking at different sites and get hit with a drive-by browser attack or something bad 562 00:50:35,750 --> 00:50:42,458 through their Yahoo! e-mail. So again, it's just perspective but again, and these are on public 563 00:50:42,458 --> 00:50:49,542 IP. This fetal monitor, I've been yakking about these for a couple years now. And so I first 564 00:50:49,542 --> 00:50:56,542 reported these in about December of 2012 and then there's also been some media coverage. So 565 00:50:56,542 --> 00:51:02,542 these have been mentioned specifically in mainstream media and I haven't really had people 566 00:51:05,292 --> 00:51:10,250 reach out to me yet about these which I was surprised because I mean if there's one thing we can 567 00:51:10,250 --> 00:51:17,083 think about is fetal monitors, my perspective is that you should have the opportunity to 568 00:51:17,083 --> 00:51:23,708 be born before you get hacked, right! (Laughter) That's not too much to ask for. Okay. And 569 00:51:23,708 --> 00:51:29,708 these are the most severe, these are the most vulnerable people in our population. I mean you 570 00:51:29,708 --> 00:51:35,708 got a mom in bed expecting a baby. Can't we do better than what we're doing here with this? 571 00:51:38,042 --> 00:51:43,875 So when Scott and I decided to collude and do this talk I really amped up. And I 572 00:51:43,875 --> 00:51:49,958 disclosured again to DHS, and then went to the manufacturer whom I'm not gonna mention the 573 00:51:49,958 --> 00:51:56,083 manufacturer, and I'm not gonna mention the device specifics on this but I also went to the FDA, 574 00:51:56,083 --> 00:52:00,792 the Office of Civil Rights and the Joint Commission because I'd gotten to the point that, you 575 00:52:00,792 --> 00:52:05,625 know, if you put these out there, you put people at risk, you deserve a fine. And that's 576 00:52:05,625 --> 00:52:11,625 the business side. Right. That's when people start paying attention. (Applause) Got to 577 00:52:15,083 --> 00:52:22,917 hit'em in the pocket. So here is a SHODAN map of the fetal monitors on public IP and it 578 00:52:22,917 --> 00:52:26,250 really doesn't disclose-- >> That's a really crappy picture! >> It's a horrible picture but, 579 00:52:26,250 --> 00:52:30,875 you know, if you look in the United States, right, you'll see one big dot. And one big dot in 580 00:52:30,875 --> 00:52:36,917 the United States is there in the center, you'll see a couple down in Florida and down in 581 00:52:36,917 --> 00:52:40,000 Puerto Rico but the ones in the U.S. you see a big dot there, and that's because of the 582 00:52:40,000 --> 00:52:44,500 cellular modem issue, right. And so it doesn't give you a geo-- SHODAN will not give you a 583 00:52:44,500 --> 00:52:48,042 ge0graphic location on that cellular modem. So we got a fetal monitor hooked up to a 584 00:52:48,042 --> 00:52:53,292 cellular modem, don't know the organization it's affiliated with, very very difficult to 585 00:52:53,292 --> 00:52:58,500 track that down. Anyone, and that gets into a phone call I had with the FDA. You know, the 586 00:52:58,500 --> 00:53:04,083 first question to the security guy was like, oh, well, how do I find these? I'm like, dude, call 587 00:53:04,083 --> 00:53:08,375 the F.B.I. >> Yeah it ends up being just so you guys are kind of doing your research, and are 588 00:53:08,375 --> 00:53:14,583 aware of that, it ends up in a field like 10 miles northeast of Potwin, Kansas, and so that 589 00:53:14,583 --> 00:53:19,000 field is actually a geographical center of the United States. And so anything that is not able to 590 00:53:19,000 --> 00:53:24,708 track a geolocation back to, that is why you'll see a huge influx outside of Potwin, Kansas 591 00:53:24,708 --> 00:53:29,042 in a field. It's not a bunch of people out there with fetal monitors and devices sitting. 592 00:53:29,042 --> 00:53:37,000 (Laughter) It's not a hacker camp in the middle of the field. >> Kansas is so boring, you 593 00:53:37,000 --> 00:53:44,083 almost want to drive around it! So here is some system details on this. Now, so there's two 594 00:53:44,083 --> 00:53:48,625 different models out there running. First is Windows 2003 server running it's running 595 00:53:48,625 --> 00:53:56,208 IIS6.0 right, 16 systems. So doing my research on available public documentation, you know, 596 00:53:56,208 --> 00:54:00,958 and that's another thing, documentation control for this on the vendor side, they get 597 00:54:00,958 --> 00:54:06,125 third party integrators, these guys pop up an FTP server and then the vendor documentation 598 00:54:06,125 --> 00:54:11,333 gets leaked out so then a guy like me can come along and then find it. Usually it's very 599 00:54:11,333 --> 00:54:16,833 tightly controlled so I knew right away after documentation that these 16 systems that are 600 00:54:16,833 --> 00:54:20,750 out there are behind on their vendor updates. And props to the vendor because on this 601 00:54:20,750 --> 00:54:24,875 particular system they are doing a good job, they're actually vetting the patches, they're 602 00:54:24,875 --> 00:54:29,375 upgrading systems and going up CDs but then you get in the situation where these are 603 00:54:29,375 --> 00:54:34,417 constantly in use and you have to have an IT department, upgrading them or you have to 604 00:54:34,417 --> 00:54:39,667 contract that out. You get smaller healthcare clinics, money is an issue. Think about 605 00:54:39,667 --> 00:54:45,250 how it is on like a Native American reservation, right, you know, these things are expensive 606 00:54:45,250 --> 00:54:52,500 to run. The second one was the 2008 server and that's IIS7.0, by the way not all these systems 607 00:54:52,500 --> 00:54:57,292 are currently exposed online so there's a historical context here but over the past couple 608 00:54:57,292 --> 00:55:02,375 years I've just seen more and more of them pop up online. So some have been retired, some 609 00:55:02,375 --> 00:55:07,458 have been taken down. So the remote access is done through remote desktop web access, which 610 00:55:07,458 --> 00:55:12,333 is done through a browser or there's a terminal services client. And when I did raise the 611 00:55:12,333 --> 00:55:17,625 question and did get in touch with FDA and vendor I couched this 'cause I knew I could get 612 00:55:17,625 --> 00:55:23,667 their attention, couched it as a HIPAA-compliant issue, not just a public IP exposure but the way 613 00:55:23,667 --> 00:55:30,458 the communication happened with the RDP clients. And there is technically ways, I'm not a 614 00:55:30,458 --> 00:55:35,542 HIPAA expert, but ways to make it HIPAA compliant, and using the FIPS, correct FIPS, approved 615 00:55:35,542 --> 00:55:42,333 crypto levels, certificate sharing and such but that really wasn't documented. From what I 616 00:55:42,333 --> 00:55:46,917 saw and from other documentation, what could have been and, yes, so there were 617 00:55:46,917 --> 00:55:50,792 some questions about that. And then again I'll give props to the vendor, because they said 618 00:55:50,792 --> 00:55:57,042 that these should be deployed on a secured connection, so meaning, you know, with a VPN 619 00:55:57,042 --> 00:56:00,833 and I believe that they will be updating their documentation. >> Yeah so that's one of the 620 00:56:00,833 --> 00:56:03,792 reasons we are not naming the vendor. We don't feel that this one is necessarily a 621 00:56:03,792 --> 00:56:10,250 manufacturer issue. If it was a manufacturer issue and they were actually recommending that we 622 00:56:10,250 --> 00:56:15,000 expose them, we probably would drop their name as I will drop a vendor name later in this 623 00:56:15,000 --> 00:56:19,250 discussion. >> Yeah stay tuned. It's gonna get a little hairy. That's all him. >> The FDA 624 00:56:19,250 --> 00:56:24,708 Module reports, so if you're not familiar with the FDA, there is a user event database that they 625 00:56:24,708 --> 00:56:29,833 have, and so what I did is correlated, I didn't do correlation. I went into FDA Mod 626 00:56:29,833 --> 00:56:34,417 and I was looking for anything that could be tied to this particular monitoring system, 627 00:56:34,417 --> 00:56:39,125 what kind of problems they've had from the field that people have reported. So some of those 628 00:56:39,125 --> 00:56:44,667 I saw that these alarm capabilities have been muted or disabled. And that led me to 629 00:56:44,667 --> 00:56:49,125 wonder, okay is this possible that, you know, these particular exposed devices, is there 630 00:56:49,125 --> 00:56:55,042 correlation with the FDA Mod database in those reports that perhaps there's an attack going 631 00:56:55,042 --> 00:57:01,667 on here that we don't know about. It's hard to tell from Mod and Mod reports are really, 632 00:57:01,667 --> 00:57:09,500 they're sanitized search interfaces are horrible. So, where we are today, is this is 633 00:57:09,500 --> 00:57:16,583 close to DHS. There's many on public IP, many are running IIS 6.0. And by the way I'm able to 634 00:57:16,583 --> 00:57:21,708 tell all this from SHODAN so I am not going to these individual systems, I'm not connecting to 635 00:57:21,708 --> 00:57:26,458 them, I'm not looking at the versions, I'm not scanning them. I can derive all this 636 00:57:26,458 --> 00:57:30,875 information from SHODAN including last scan date so there's a historical record in 637 00:57:30,875 --> 00:57:36,208 SHODAN. The vendor did reach out to me. We had a conference call. They are interested in what they 638 00:57:36,208 --> 00:57:42,458 characterize as a customer misuse case. And that is completely accurate and really 639 00:57:42,458 --> 00:57:45,917 it's the beginning of security researcher communication. You know, one of their security 640 00:57:45,917 --> 00:57:50,958 people was like, yeah, I've known about you for a few years, you have the med sector group, 641 00:57:50,958 --> 00:57:54,333 you know, we get a little apprehensive talking to you. And the reason is 'cause they don't 642 00:57:54,333 --> 00:57:58,375 have have you locked in right, I'm not a under an NDA, I'm not an employee, I'm just a guy out 643 00:57:58,375 --> 00:58:03,042 here who is, you know, interested in this, and wants to improve public safety. So, you 644 00:58:03,042 --> 00:58:07,833 know, it's a wildcard, right. How do you handle somebody like that? And I can appreciate that, 645 00:58:07,833 --> 00:58:12,583 so. I believe that they might have sent a folk or two here and I hope we can rap up here later, 646 00:58:12,583 --> 00:58:17,250 you know, continue to build has relationship because this is where it's gonna count. >> 647 00:58:17,250 --> 00:58:22,750 Lessons learned: really, you know, we need a better reporting method. We need to have some 648 00:58:22,750 --> 00:58:27,500 teeth in something and a way to track these formal government levels, we need some 649 00:58:27,500 --> 00:58:31,833 coordination happening across these different agencies. I'd love to see like a task force 650 00:58:31,833 --> 00:58:36,750 that evolved out of this where okay we found a device, we're able to get the public IP 651 00:58:36,750 --> 00:58:42,917 correlated to a healthcare provider, send the people in, ask them to disable it. If 652 00:58:42,917 --> 00:58:49,833 there's a PHI leak or something along those lines consider a fine. Again, I'd hate to see a 653 00:58:49,833 --> 00:58:55,625 small poor hospital out in the middle of nowhere get hammered with a HIPAA fine but again it 654 00:58:55,625 --> 00:59:01,625 makes the news and hopefully that drives change. >> So let's talk about some adversary 655 00:59:03,875 --> 00:59:08,250 misconceptions and some e-mails that I've gotten on our research, public comments, 656 00:59:08,250 --> 00:59:13,792 people that I've had to deal with. One of the things that I get is: Well, who the heck would 657 00:59:13,792 --> 00:59:17,542 do this? They only care about financial gain, right. They don't care about anything else. 658 00:59:17,542 --> 00:59:21,083 All they care about is going into those Pacs systems, actually draining patient data, 659 00:59:21,083 --> 00:59:26,000 and selling it. And yeah that's true, Russians, they're gonna sell it right, that's what they 660 00:59:26,000 --> 00:59:32,042 do. But the other thing, the other misconception, and honestly there was this guy that 661 00:59:32,042 --> 00:59:38,042 posted on a recent article and he actually said ignorant people, he said that, hey, these 662 00:59:41,167 --> 00:59:46,000 people lives in caves and you're giving them all the information to get into the devices. And 663 00:59:46,000 --> 00:59:50,583 they're not smart enough to figure this out on their own 'cause they live in caves. I had 664 00:59:50,583 --> 00:59:55,917 e-mail communications with this guy like 30 times and he just wouldn't give it up. He was so 665 00:59:55,917 --> 01:00:00,333 convinced that they aren't technically adept enough to carry this out. And as we showed 666 01:00:00,333 --> 01:00:07,125 you, this is not a technical attack here. This is basic Security 101 concepts that one 667 01:00:07,125 --> 01:00:12,000 thing gets missed and there is kind of this cascading effect for patient safety right, and it 668 01:00:12,000 --> 01:00:18,625 opens up this huge threat model that we have to be aware of. >> So who do we need to worry 669 01:00:18,625 --> 01:00:24,042 about? I think, you know, terrorists and extremists, technically adept, when you get 670 01:00:24,042 --> 01:00:30,208 into, you know, ISIS, when you get into nation states, that's kind of who we need to worry 671 01:00:30,208 --> 01:00:34,583 about and that's what I thought about. And then Shawn, and he can talk to this, he brought up 672 01:00:34,583 --> 01:00:39,500 this interesting article that I'd never thought of, oh man, a patient, maybe themselves could 673 01:00:39,500 --> 01:00:42,667 be an adversary in a way. So I'll let you talk about this article. >> I'll quickly run 674 01:00:42,667 --> 01:00:46,250 through this. So here is the situation, you know. You've got a patient in a hospital with a 675 01:00:46,250 --> 01:00:51,250 gunshot wound, guy's lying in bed, he's got his laptop there, and he's got-. >> This is 676 01:00:51,250 --> 01:00:56,500 awesome by the way. >>And he's getting a morphine drip right through an infusion pump. So 677 01:00:56,500 --> 01:01:02,167 obviously he's like I'm in pain, I want more juice. How do I do this? The guy went online. 678 01:01:02,167 --> 01:01:05,750 (Laughter) >> We didn't make this up. There is the link. >> Guy went online, found the 679 01:01:05,750 --> 01:01:12,583 manual for this infusion pump and then was able to break into it and then reprogram it and he 680 01:01:12,583 --> 01:01:16,958 ended up going into an overdose and then it happened to a couple guys in this healthcare 681 01:01:16,958 --> 01:01:24,917 organization in Australia. I'm sorry, Austria, and, yeah, so you know it's just something 682 01:01:24,917 --> 01:01:28,083 when you think about, it's like, oh, we always think about, you know, who is at risk and who is 683 01:01:28,083 --> 01:01:31,542 the adversary here. Well, you know, the guy who's being treated for this could very well 684 01:01:31,542 --> 01:01:36,958 be the adversary from a healthcare standpoint. >> So one of the things that really, 685 01:01:36,958 --> 01:01:44,000 you know, gets scary and this is easy to kinda dismiss as a, just theoretical or you're watching 686 01:01:44,000 --> 01:01:46,667 too much TV or reading too many books, but think about these Boston marathon bombings and the 687 01:01:46,667 --> 01:01:53,875 Tsarnaev brothers, right, and think about if they had set off ten bombs and then, you know, 688 01:01:53,875 --> 01:02:00,042 timed another ten to go off, right, when all the emergency personnel came in. This is what 689 01:02:00,042 --> 01:02:05,042 happens in countries like Israel, when we see the first bomb goes off, all the emergency 690 01:02:05,042 --> 01:02:09,333 personnel rush in there, then the second one goes off. And what I think we're going to need 691 01:02:09,333 --> 01:02:14,167 to start worrying about in the future is gonna be the electronic attacks against the 692 01:02:14,167 --> 01:02:19,667 critical infrastructure like hospitals and power but more so hospitals because they're such 693 01:02:19,667 --> 01:02:23,875 soft targets. Think about the impact of a, you know, a bomb goes off, all the EMT guys get 694 01:02:23,875 --> 01:02:27,167 hit with the second bomb, then they're bringing everybody to the hospital, and then 695 01:02:27,167 --> 01:02:33,333 everything shuts down in the hospital. Even Boston Children's recently got hit on their public 696 01:02:33,333 --> 01:02:41,042 website because of the Peletier case which Anonymous picked up on so we are seeing this already 697 01:02:41,042 --> 01:02:44,958 starting to manifest itself. And it's all about capability, right. The capability is there 698 01:02:44,958 --> 01:02:50,667 to do this. >> I think one thing to add, too, I think this is where, you know, historically 699 01:02:50,667 --> 01:02:55,583 DHS and ICS-CERT are the ones issuing advisories, it wasn't until April that the F.B.I. all 700 01:02:55,583 --> 01:03:00,333 of a sudden got involved and they issued two privacy industry notices last April. They kind of 701 01:03:00,333 --> 01:03:05,875 came out of left field, like why the hell is the F.B.I. all of a sudden issuing private industry 702 01:03:05,875 --> 01:03:09,458 notices about risks in medical device exposure? This is one of their fears, right, is the 703 01:03:09,458 --> 01:03:14,167 combined attack and that's the type of thing that they are looking at, that's why they are 704 01:03:14,167 --> 01:03:17,917 looking into the space a little bit more closely and why they've, you know, we started to 705 01:03:17,917 --> 01:03:23,500 work with them and build that relationship up is really these types of scenarios. >> Right, 706 01:03:23,500 --> 01:03:29,500 so the military term for this is force multiply. >> So Ed on the bottom here, Cybercity, they are 707 01:03:33,292 --> 01:03:37,167 already doing this, right. You know, the government obviously is looking at it and they think 708 01:03:37,167 --> 01:03:41,292 it's a risk, we should probably take a look at it, I mean Ed has been doing this for a few years 709 01:03:41,292 --> 01:03:45,375 now but Cybercity has basically, they have all that critical infrastructure. They have 710 01:03:45,375 --> 01:03:49,708 detailed all that critical infrastructure, so they have the healthcare, they have financial, 711 01:03:49,708 --> 01:03:54,917 they have the ICS stuff, they have transportation, it's just a big, you know, training lab for 712 01:03:54,917 --> 01:04:00,208 if a combined attack took place, how would we be able to react for it? So it is taking place 713 01:04:00,208 --> 01:04:06,708 already. >> So really, one of the questions that comes into this is, this is a whole new 714 01:04:06,708 --> 01:04:11,708 area of medical devices. How do you even know that a, if a medical device was hacked? You 715 01:04:11,708 --> 01:04:15,375 know, one of the first things that you'll read about when you start looking in this space in 716 01:04:15,375 --> 01:04:20,708 the articles is to say there's no documented evidence of a medical device attack happening. 717 01:04:20,708 --> 01:04:26,625 But how would you know? I mean we don't have the forensics capability really mature yet at 718 01:04:26,625 --> 01:04:31,250 all in this except for there some is open source stuff, right, that's built on cots 719 01:04:31,250 --> 01:04:35,583 equipment. But it's mostly closed-source code. Vendors aren't sharing this code. And 720 01:04:35,583 --> 01:04:39,292 then with these devices you need specialized diagnostic equipment, you're running 721 01:04:39,292 --> 01:04:44,792 proprietary protocols and code so it's very very difficult and you need specialized people and 722 01:04:44,792 --> 01:04:50,792 a vendor to help you with any type of cyberforensics exercise. Then you get into the device 723 01:04:52,792 --> 01:04:57,542 experts so, you know, looking on LinkedIn I only found two people who really claimed any 724 01:04:57,542 --> 01:05:01,500 expertise. >> Definitely an official source, way better than Wikipedia! (Laughter) >> Yeah 725 01:05:01,500 --> 01:05:06,833 but only two people that I found. And the first was you know, a woman from the FDA, 726 01:05:06,833 --> 01:05:11,958 total track record. >> Not an expert. >> Then the second was a retired F.B.I. agent, who was 727 01:05:11,958 --> 01:05:18,458 one of the founding members of their cybersquads, so those are like two people, but. So those 728 01:05:18,458 --> 01:05:23,042 of you who are thinking about forensics in the future and maybe if you are in healthcare, 729 01:05:23,042 --> 01:05:26,917 this is something that is to consider as far as a career path. >> And one thing here on 730 01:05:26,917 --> 01:05:32,000 this last bullet point that is important to understand, too, when we talk about, you know, a 731 01:05:32,000 --> 01:05:35,292 low assurance that an attack, either intentional or unintentional, hasn't taken 732 01:05:35,292 --> 01:05:41,208 place against these devices with adverse events. The FDA adjudication process of a 733 01:05:41,208 --> 01:05:47,458 medical device related malfunction that gets reported. Healthcare organization has the 734 01:05:47,458 --> 01:05:51,875 responsibility in requirement to report a medical device related malfunction, and so they report 735 01:05:51,875 --> 01:05:56,125 that to the FDA. Well if you go to the FDA's website it will directly tell you and their 736 01:05:56,125 --> 01:06:02,625 quotes are several hundred thousand of medical device-related malfunctions. So 737 01:06:02,625 --> 01:06:07,042 they adjudicate this. If something happens and there is an adverse event for a patient 738 01:06:07,042 --> 01:06:11,708 they do a clinical adjudication to say, oh, the patient died from pneumonia on a ventilator 739 01:06:11,708 --> 01:06:16,208 or there's, you know, they died of old age or that type of thing. If not they don't really 740 01:06:16,208 --> 01:06:20,750 do, you know, security. They don't look at forensics because there's not a whole lot of 741 01:06:20,750 --> 01:06:25,625 information there to look at. And so they throw it in this generic button, or bucket of 742 01:06:25,625 --> 01:06:30,417 several hundred thousand medical device-related adverse, you know, deaths and serious 743 01:06:30,417 --> 01:06:36,583 injuries every year. We don't know what they are. And then the Mod reports suck and they're 744 01:06:36,583 --> 01:06:42,375 very specific and script out. So we don't really have the information and we don't have 745 01:06:42,375 --> 01:06:48,875 the forensic details so, you know, how could we really prove this at this point? >> So let's 746 01:06:48,875 --> 01:06:55,292 get us into HIPAA. I'm gonna flip through this really quick. Oh, you're switching with me. 747 01:06:55,292 --> 01:06:58,333 >> You know, yeah, HIPAA. I'm not gonna argue that it's ineffective, but why are we in 748 01:06:58,333 --> 01:07:03,042 this space? Doesn't it protect us? I get this too. I get all these e-mails all day long, why 749 01:07:03,042 --> 01:07:08,292 isn't HIPAA doing something, right? HIPAA focuses on patient privacy, it's not focused on 750 01:07:08,292 --> 01:07:13,500 necessarily patient safety. Human life is much more irreplaceable than PHI. So I 751 01:07:13,500 --> 01:07:17,750 would encourage you guys to start looking at that if you work for healthcare 752 01:07:17,750 --> 01:07:24,500 organizations, definitely start looking into that. It doesn't focus on medical devices and it 753 01:07:24,500 --> 01:07:29,500 definitely doesn't focus on adversarial resiliency testing at all. Don't the federal 754 01:07:29,500 --> 01:07:34,333 agencies protect you? That's another one. Shouldn't the FDA be doing this, right? Well, it's 755 01:07:34,333 --> 01:07:38,708 ultimately your responsibility as a manufacturer, as a healthcare organization, they 756 01:07:38,708 --> 01:07:42,333 have told healthcare organizations, they've told manufacturers since last year 757 01:07:42,333 --> 01:07:48,333 when Billy Rios, Terry McCorkle came out with the infamous 300 List and these are some of the 758 01:07:50,375 --> 01:07:55,458 alerts if you want to look them up later, that came out specifically telling healthcare 759 01:07:55,458 --> 01:07:59,917 organizations and medical device manufacturers that they at this point aren't gonna get involved, 760 01:07:59,917 --> 01:08:06,000 and that it's their responsibility to take care of it. So how did healthcare kinda 761 01:08:06,000 --> 01:08:12,833 get to the state that it's at, you know, ten years behind? It's back to HIPAA in my opinion. If 762 01:08:12,833 --> 01:08:17,833 you work in the industry, information security programs in healthcare were primarily funded 763 01:08:17,833 --> 01:08:23,542 and developed to comply with HIPAA. So we all know security is not compliance or information 764 01:08:23,542 --> 01:08:28,417 assurance but that's how these programs have been built, they have been built for check box 765 01:08:28,417 --> 01:08:32,125 security, and we buy this appliance and we check this box, and oh, hey, we are secure 766 01:08:32,125 --> 01:08:39,667 'cause HIPAA says we are secure. Where are the issues in the manufacturers? Well we've never 767 01:08:39,667 --> 01:08:44,042 had, you know, this is kind of the similar space, even in the auto industry, right. 768 01:08:44,042 --> 01:08:48,500 Historically especially when you look at, you know, life cycles of these devices, that for 769 01:08:48,500 --> 01:08:53,458 implantables, if they're not on expedited approval from the FDA from prototype to, you know, 770 01:08:53,458 --> 01:08:59,708 market release, it could be 12 to 13 years. So we never have had to design for adversarial 771 01:08:59,708 --> 01:09:03,833 threats and never really thought about it. We took these medical devices that existed and we just 772 01:09:03,833 --> 01:09:07,667 decided oh it would be great if we could get data on this and managed them remotely so we 773 01:09:07,667 --> 01:09:12,583 don't have to waste time, and be more efficient but now we kinda have the unintended consequences 774 01:09:12,583 --> 01:09:19,625 that we are seeing here in our research across healthcare organizations. And the other 775 01:09:19,625 --> 01:09:24,042 thing, you know, they haven't fully embraced, this is getting better, most of the large 776 01:09:24,042 --> 01:09:31,250 healthcare manufacturers are starting to reach out, we're starting to build those 777 01:09:31,250 --> 01:09:35,375 relationships, there is a lot of one-offs, you'll get to one of these examples, of a company 778 01:09:35,375 --> 01:09:41,375 that just will not talk to us coming up here that we're gonna show a use case on. But so if 779 01:09:44,625 --> 01:09:49,833 you reach out to us and actually talk to us we probably won't be as mean to ya! But no, you know, 780 01:09:49,833 --> 01:09:54,375 we are really there, we have a combined effort and they are starting to embrace it. We are 781 01:09:54,375 --> 01:09:58,125 doing a really good job, we're making a lot of progress there so I'm definitely hopeful, you 782 01:09:58,125 --> 01:10:03,625 know, that that will continue. You know, it's not, when you talk to the manufacturer and you 783 01:10:03,625 --> 01:10:08,708 know they don't care. You know, to their benefit, I mean they are very large, a lot of this 784 01:10:08,708 --> 01:10:14,458 does take time, it is a culture change and so they are getting there. They are building out 785 01:10:14,458 --> 01:10:19,250 these teams. They are hiring the right people and giving them internally the authority but 786 01:10:19,250 --> 01:10:23,083 this is just some of the larger manufacturers, not these one-offs, not to mention when we 787 01:10:23,083 --> 01:10:30,792 get into digital health and mobile health things. So does anyone work for healthcare 788 01:10:30,792 --> 01:10:37,708 organizations that wants to admit it? Okay. All right. So how many of you have been told 789 01:10:37,708 --> 01:10:43,583 by a manufacturer that you can't patch your system, like your medical devices, right? Exactly. 790 01:10:43,583 --> 01:10:48,833 It's a crutch. And here is the link. I mean like Shawn said, they've been telling you, the 791 01:10:48,833 --> 01:10:52,958 FDA, there is, you know, cybersecurity clause for patching. There is a very small 792 01:10:52,958 --> 01:10:57,208 percentage that would actually have to go back through 510 k, the only case is if it's 793 01:10:57,208 --> 01:11:03,375 clinical care issue, patient safety issue on some types of implantables. Who else has been 794 01:11:03,375 --> 01:11:07,292 told they can't change hard-coded credentials that they may have located for the 795 01:11:07,292 --> 01:11:11,833 manufacturer, right? All right. So that gets into my next bullet point. I want to, you know, 796 01:11:11,833 --> 01:11:17,167 spend a little time kind of clarifying this. This is a big point. Both sides need to 797 01:11:17,167 --> 01:11:21,333 understand this. So if you are in healthcare, you know, please listen to this. On the 798 01:11:21,333 --> 01:11:27,333 healthcare side, whose biomedical teams are integrated with IS? Oh my God, there is not 799 01:11:30,250 --> 01:11:34,792 a single hand that I can see. But I'm a little blinded. >> We have two over there. >> 800 01:11:34,792 --> 01:11:41,083 Awesome! That is great. So how this works and where this disconnect is, is you as someone 801 01:11:41,083 --> 01:11:46,625 in security, you find a bug or a flaw in a device that you want to report. You go to your Biomed 802 01:11:46,625 --> 01:11:52,500 technician, your Biomed tech takes your report, interprets it in his little Biomed language 803 01:11:52,500 --> 01:11:57,042 and who does he contact from the manufacturer? He contacts the support technician at the 804 01:11:57,042 --> 01:12:02,292 manufacturer. Well the support technician is not their security people, doesn't have any idea, 805 01:12:02,292 --> 01:12:06,833 so they get your report that says we have a hard coded credential, how it works on the 806 01:12:06,833 --> 01:12:12,250 manufacturer's side is that field support tech goes to their supervisor and says, hey, we 807 01:12:12,250 --> 01:12:17,708 have a report from a customer that we need to change this. And the supervisor is like, hey, how 808 01:12:17,708 --> 01:12:24,333 the hell are we gonna get into the customer's systems if we change the password, right? So 809 01:12:24,333 --> 01:12:29,250 it stops right there. And he's not thinking security, right. He's not their security person. 810 01:12:29,250 --> 01:12:32,833 But he tells that field support tech to tell the Biomed person that they can't change it. And 811 01:12:32,833 --> 01:12:36,333 so it comes back to the health organization in a way as the official response from that 812 01:12:36,333 --> 01:12:40,292 healthcare organization is they're not gonna fix it and we don't push it anymore. So 813 01:12:40,292 --> 01:12:44,000 there's a big disconnect there on both sides, there's a disconnect between Biomed and IS 814 01:12:44,000 --> 01:12:48,292 on the healthcare side and there's a disconnect between how do we inbound handle, you know, 815 01:12:48,292 --> 01:12:53,167 vulnerabilities at the manufacturer to make sure that the security folks at those 816 01:12:53,167 --> 01:12:57,250 organizations that have implemented those programs can effectively be aware of them 817 01:12:57,250 --> 01:13:01,750 first off, and then drive the process behind that to make sure they're resolved. And also I 818 01:13:01,750 --> 01:13:07,750 would highly encourage you to, you know, know those information security people so if you don't 819 01:13:07,750 --> 01:13:12,167 know especially at your big vendors, the ones you spend lots of money and have lots of 820 01:13:12,167 --> 01:13:18,042 equipment with, reach out and find out who those folks are and build up those relationships. 821 01:13:18,042 --> 01:13:24,208 'Cause it's very important. >> So when it comes to patching, you know, the question is: Yes, 822 01:13:24,208 --> 01:13:32,000 you can patch. But should you? So there's a good eight, 10 years of FDA guidance saying 823 01:13:32,000 --> 01:13:36,250 that you can patch these systems but this is something that you really need to work on your 824 01:13:36,250 --> 01:13:42,292 vendors with and do coordination because you have got a very complex ecosystem going on here 825 01:13:42,292 --> 01:13:49,208 and then what if something that you do in-house breaks the device? So, you know, the vendor 826 01:13:49,208 --> 01:13:54,458 coordination has to happen with this issue and there's gonna be some smaller vendors who are not 827 01:13:54,458 --> 01:14:01,250 going to be ready to work with you on this as well as a larger vendor would be. So the other 828 01:14:01,250 --> 01:14:06,500 thing is many healthcare organizations are reluctant to patch just because of the 829 01:14:06,500 --> 01:14:11,083 complexity and the changes that can happen in these systems. And if we go back into the FDA Mod 830 01:14:11,083 --> 01:14:16,500 reports, there's many many examples of patches that have gone wrong or healthcare 831 01:14:16,500 --> 01:14:22,500 organizations that are comfortable patching say the computer PC that connects to the 832 01:14:22,500 --> 01:14:27,542 medical device that's running, both are running Windows, they'll patch one, the one you 833 01:14:27,542 --> 01:14:31,833 used to run the device but they don't want to patch the device itself that actually connects to 834 01:14:31,833 --> 01:14:37,833 the patient. Which is completely understandable. The anti-virus question is another one. And you 835 01:14:40,250 --> 01:14:46,000 know, we can get off on a side tangent here with anti-virus but the main points that I want to 836 01:14:46,000 --> 01:14:53,125 bring were that there are a lot of reports of FDA MAUDE, in FDA MAUDE of negative impact of 837 01:14:53,125 --> 01:14:59,042 anti-virus, and that's like everything from, oh your 90-day license expired and, you know, 838 01:14:59,042 --> 01:15:05,417 this is an OR situation and then this pop up is coming up saying license has expired. Everything 839 01:15:05,417 --> 01:15:11,417 to bad McAfee, that's not to pick on McAfee at all, but if you recall back in 21, April 840 01:15:13,417 --> 01:15:20,333 2010 this bad DAT went out and it identified a core Windows file as malicious and then all 841 01:15:20,333 --> 01:15:25,042 these machines, all these XP machines just started going into a continuous reboot. So if you 842 01:15:25,042 --> 01:15:29,833 were working in healthcare organization at that time you were running around manually 843 01:15:29,833 --> 01:15:36,375 hitting every single box and fixing them. And just a small example is a third of the 844 01:15:36,375 --> 01:15:41,917 hospitals in Rhode Island were impacted by this, so many, many people were, especially if you 845 01:15:41,917 --> 01:15:48,292 were, if you have been doing this a while. There's also direct events of AV deleting, 846 01:15:48,292 --> 01:15:55,792 fetal monitoring logs. >> When they actually log. >> And it's a, you know, this is a complex 847 01:15:55,792 --> 01:16:01,250 issue. And then, you know, you'll have some clients or customers that push back on 848 01:16:01,250 --> 01:16:06,208 vendors saying we have to run antivirus on this so the vendors are in a bad position and they 849 01:16:06,208 --> 01:16:10,583 may recommend one or they may not recommend one and then the other thing they'll do often, 850 01:16:10,583 --> 01:16:15,250 you'll see this in the documentation is say disable this particular feature of the 851 01:16:15,250 --> 01:16:21,708 antivirus so they'll say disable on-demand scanning, which, okay, now we have this antivirus on 852 01:16:21,708 --> 01:16:27,667 there. We have checked our happy check box but then we have basically hobbled a key 853 01:16:27,667 --> 01:16:33,083 protection mechanism and function of this antivirus itself. So, you know, again, it 854 01:16:33,083 --> 01:16:37,375 comes back to a risk basis here. What are we really trying to accomplish here? Are we just 855 01:16:37,375 --> 01:16:41,542 trying to check a check box or are we trying to reduce risk because there could be cases 856 01:16:41,542 --> 01:16:46,208 where, you know, many cases of why would you even want antivirus on there? But unless 857 01:16:46,208 --> 01:16:51,333 you are getting it directly from the vendor you probably don't want to run it. >> So solutions 858 01:16:51,333 --> 01:16:55,708 and recommendations, I'll just touch these quick, right. I mean, external attacks service 859 01:16:55,708 --> 01:17:00,583 and hardening, that's important, we have obviously shown you that it's not being done 860 01:17:00,583 --> 01:17:06,500 appropriately, right. Mitigate. First you need to recognize and you actually need to use a tool 861 01:17:06,500 --> 01:17:11,833 like SHODAN in your organization and start recognizing those and work to mitigate them. You know, 862 01:17:11,833 --> 01:17:17,208 you don't need to use SHODAN, you can the API for automation. You can, you know, use continual 863 01:17:17,208 --> 01:17:22,500 monitoring, mass scan, ZMAP, those types of tools you can also use, you don't need to use 864 01:17:22,500 --> 01:17:27,542 just SHODAN. You know, make the external perimeter -- (Inaudible) -- proof, we don't 865 01:17:27,542 --> 01:17:31,375 see this in a lot healthcare organizations, we don't see these skill sets being employed, 866 01:17:31,375 --> 01:17:34,833 because again going back to HIPAA we see compliance and information assurance driving 867 01:17:34,833 --> 01:17:39,125 that budget but we need to get these skill sets in there, you need to look at it. We are 868 01:17:39,125 --> 01:17:45,375 clearly showing you that we are way behind in the healthcare sector. Stop the bleeding, 869 01:17:45,375 --> 01:17:51,542 right. Check and make sure SMV isn't open, as simple as it sounds. I mean look at the 870 01:17:51,542 --> 01:17:54,958 exposure, look at the information attacker and get on your systems through this, it's 871 01:17:54,958 --> 01:18:02,500 significant. It's your medical devices that have to do with patient safety issues. And 872 01:18:02,500 --> 01:18:06,875 resilience testing, right. Red teaming. Start working on building out those programs and 873 01:18:06,875 --> 01:18:11,917 really, you know, harden those devices, don't leave them wide open if you are a large 874 01:18:11,917 --> 01:18:17,875 healthcare organization or any organization without any type of password so please take a look 875 01:18:17,875 --> 01:18:22,625 at those. What do we need from healthcare? Kind of talked on that. You know, it's internal 876 01:18:22,625 --> 01:18:28,458 programs focused on medical device security. We really need to start looking at that. You 877 01:18:28,458 --> 01:18:32,833 need to start requiring security testing during your vendor selection. We'll talk about that 878 01:18:32,833 --> 01:18:35,875 a little bit later and how you can implement that into your procurement, your vendor 879 01:18:35,875 --> 01:18:40,167 selection process and really how do you tie that in and how do you get that inside the 880 01:18:40,167 --> 01:18:43,542 healthcare organization? Well you've gotta tie it to your mission and you've gotta tie it 881 01:18:43,542 --> 01:18:47,750 to patient safety. That's what the board level, that's what the executives are gonna care about. 882 01:18:47,750 --> 01:18:52,458 And it definitely, when it is talking about securing medical devices, is tied to that 883 01:18:52,458 --> 01:18:58,458 mission. >> So has anyone in here has ever heard of a MDS2 form? A couple folks. >> All in 884 01:19:01,250 --> 01:19:07,542 healthcare who have heard of it! >> That's good. So an MDS2 form is a form that came, I think 885 01:19:07,542 --> 01:19:12,208 came out of HEMS, it's been around for several years, basically it goes through some 886 01:19:12,208 --> 01:19:18,875 really good, almost a checklist function. There is a place for that. About authentication and 887 01:19:18,875 --> 01:19:24,125 you know, how accounts are used and big vendors, major vendors will have that form on hand for 888 01:19:24,125 --> 01:19:28,875 their systems. That's something which you should be asking your vendors for and then there's 889 01:19:28,875 --> 01:19:33,458 recently been some updates and addendums to that and I think that's a great form to start to 890 01:19:33,458 --> 01:19:38,667 build on. And then of course you know, we need to have more responsible disclosure and then, 891 01:19:38,667 --> 01:19:44,750 you know, HHS and OCR, bringing in law enforcement because this will be moving into a criminal 892 01:19:44,750 --> 01:19:50,167 realm, I think. People watch "Homeland," there's a lot of sexiness of these attacks, 893 01:19:50,167 --> 01:19:55,375 that's appealing to some of these demented personalities out there, so I think it's a 894 01:19:55,375 --> 01:20:01,208 possibility. And now really one of the more interesting things that I've seen coming over the 895 01:20:01,208 --> 01:20:06,750 past year has been some healthcare organizations are bringing in indemnification 896 01:20:06,750 --> 01:20:11,250 clauses into their contracts. So what that means is you know, security and biomedical need to 897 01:20:11,250 --> 01:20:16,417 get with legal in the organization and then push back on the vendors and say well, if 898 01:20:16,417 --> 01:20:21,000 something you know, really bad does happen here and then who is going to own the liability on 899 01:20:21,000 --> 01:20:27,000 this. >> Disclosure reporting. This is pretty easy. DHS, ICS-CERT, kind of the 900 01:20:33,917 --> 01:20:39,083 agencies. Manufacturers if possible, I say if possible because this example that I'm 901 01:20:39,083 --> 01:20:43,667 about to give you, they won't return any of my calls. I won't responsibly disclose it. But 902 01:20:43,667 --> 01:20:47,667 they won't talk to me. Or get back to me. Apparently they haven't gotten back to DHS 903 01:20:47,667 --> 01:20:51,625 either. 'Cause I have not heard anything. Healthcare organizations you know, you 904 01:20:51,625 --> 01:20:55,375 probably should go to your manufacturer first, if you feel they are not responding, know 905 01:20:55,375 --> 01:20:59,167 that it will take time but if you feel they are not working on it, not addressing it, you know, 906 01:20:59,167 --> 01:21:05,167 we need to start looking at sending those over to ICS-CERT as well as the FDA. 907 01:21:07,500 --> 01:21:12,167 Accessibility to medical devices, I think, Shawn, you can kinda talk to the stereotypical 908 01:21:12,167 --> 01:21:16,083 why people don't get into research involving medical devices. >> Sure, so, you know, 909 01:21:16,083 --> 01:21:21,625 they're really hard to get a hold of, right. So one of the things is you know, these are Rx 910 01:21:21,625 --> 01:21:26,083 only, they're prescription only and they're also very expensive. You'r not gonna go out there and 911 01:21:26,083 --> 01:21:30,792 buy you know, a radiology machine. You may not even be able to, you can't get the 912 01:21:30,792 --> 01:21:35,833 permit for it you know. There's a lot of hurdles to jump on this. And then you see if you 913 01:21:35,833 --> 01:21:39,667 look at the security researchers over the past years who have been working on this, they have 914 01:21:39,667 --> 01:21:43,500 been hacking their own devices right, so which also brings in a whole other level of personal 915 01:21:43,500 --> 01:21:47,917 ownership and credibility to this because they are not just security researchers, they're 916 01:21:47,917 --> 01:21:53,792 patients. But you know, though, you can buy these off of eBay, you can go right online right 917 01:21:53,792 --> 01:21:58,208 now and even though it's against eBay's technical terms of services to sell medical 918 01:21:58,208 --> 01:22:02,792 devices, they sell'em on there just like you can buy you know, a fake Cisco router of off eBay, 919 01:22:02,792 --> 01:22:07,208 and I've been able to do that for years. Medwow is another site. But here is the problem 920 01:22:07,208 --> 01:22:11,875 with that, you know. These have already been end-of-lifed, they are recalled, it's not 921 01:22:11,875 --> 01:22:17,583 current-running software so it's not really attacking you know, the actual current software. 922 01:22:17,583 --> 01:22:22,417 And then the other thing is you know, there's gonna be a lot of, this is a whole ecosystem as we 923 01:22:22,417 --> 01:22:26,208 continue to talk about, so there's gonna be you know, components you're gonna need to 924 01:22:26,208 --> 01:22:31,458 have to get that device even up and running and get an IP network and IP address and 925 01:22:31,458 --> 01:22:36,792 networked to even you know, start to develop an attack service. You want to talk about 926 01:22:36,792 --> 01:22:40,250 the consulting stuff? >> Yeah, so consulting, I mean obviously, if you are not doing independent 927 01:22:40,250 --> 01:22:45,458 research, and buying it, you're in a lot of cases historically you are gonna end up in NDA. 928 01:22:45,458 --> 01:22:51,625 What we're starting to see, we have had a few clients that will give access to non-identifiable 929 01:22:51,625 --> 01:22:55,875 data clauses so that we can talk about it openly in non-descriptive fashions so 930 01:22:55,875 --> 01:23:00,292 we're starting to see that. I think there is more push to that and more coordination in 931 01:23:00,292 --> 01:23:05,792 disclosure. So now Shawn kinda talked about you know, hey this is why people don't get involved 932 01:23:05,792 --> 01:23:10,000 in security research. We can't get our hands on the devices. I am going to give you a use case 933 01:23:10,000 --> 01:23:16,083 here that will hopefully paint the picture that you know what, you may not need your hands on 934 01:23:16,083 --> 01:23:20,042 these devices but a different way to think. We need more people looking at these issues. 935 01:23:20,042 --> 01:23:26,917 I can't do it by myself. So please take a look at this. One of the things is obviously 936 01:23:26,917 --> 01:23:31,042 service technician manuals. They contain a lot of information that we'll show you here, full 937 01:23:31,042 --> 01:23:36,000 architectural diagrams, another thing is you can always do patent searches, manufacturers 938 01:23:36,000 --> 01:23:42,958 love to put all the details on their patent applications so that nobody steals their idea or 939 01:23:42,958 --> 01:23:49,208 uses it. So start doing that and I'm gonna show you an example here of how that works. And it's 940 01:23:49,208 --> 01:23:53,875 gonna be on the defiable right, so there's the vendor name. It's Zoll. Some specific ones on the 941 01:23:53,875 --> 01:23:58,750 next series, I'll get into those later on. These are defibs, they're on the public IP space, 942 01:23:58,750 --> 01:24:03,917 they sit in an ambulance, they have like a 12-vote lead and then they transmit all that back 943 01:24:03,917 --> 01:24:08,167 to the ED before arrival. So here they are sitting on public IP space, they're running 944 01:24:08,167 --> 01:24:12,542 Verizon 'cause they're running those other networks, well there is also a web interface, so 945 01:24:12,542 --> 01:24:17,125 let's go to the web interface, right. Oh God, I need a certificate. Great. Root 946 01:24:17,125 --> 01:24:24,000 certificate right on the landing page. Let's download it. Awesome security, right? Well it's also 947 01:24:24,000 --> 01:24:30,000 the first defib and just out of disclosure I've never actually had my hands on this device, so 948 01:24:34,000 --> 01:24:38,042 I'm doing this to paint the picture of the documentation. >> So wireless, it uses UR for 949 01:24:38,042 --> 01:24:45,125 communication in these systems. The communication processor talks back to the main system 950 01:24:45,125 --> 01:24:48,583 board, so that's the architectural diagram right there, so it's on the same 951 01:24:48,583 --> 01:24:53,500 server, with receive and transmit. In order to import config here is your config file 952 01:24:53,500 --> 01:24:58,250 out of the documention you need to import in order to change the configuration settings. All 953 01:24:58,250 --> 01:25:01,583 right. What are the critical values that I need to change, what would an attacker need to 954 01:25:01,583 --> 01:25:06,167 change to cause a patient harm, right? Well, these are critical values as you can see to our 955 01:25:06,167 --> 01:25:11,542 logging turned off by default. Default patient mode, okay here are some values inside of those 956 01:25:11,542 --> 01:25:17,083 configuration files. If I change that adult to, one is set for pediatric to adult, it's gonna 957 01:25:17,083 --> 01:25:22,167 change the default like joules that are delivered from that defib. Need to do factory 958 01:25:22,167 --> 01:25:28,167 resell, restore, right, it says here oh I need an authorized supervised passcode. Well, here 959 01:25:30,583 --> 01:25:34,167 is how you get to it through the supervisor menu. As you can see once you get to the supervisor 960 01:25:34,167 --> 01:25:38,250 menu, there's all the config settings. Many of those relate back to the critical settings 961 01:25:38,250 --> 01:25:43,292 that I just showed you. So we still have the issue of how do we get into the supervisor mode. 962 01:25:43,292 --> 01:25:49,292 Oh, there is your password, 1234. (Laughter and applause) So that's all you, also you can 963 01:25:51,458 --> 01:25:55,917 clear logs. So you can completely wipe any traces of this happening. Before I get to 964 01:25:55,917 --> 01:26:01,708 this next slide here, I need to say that I reached out to this manufacturer numerous times. 965 01:26:01,708 --> 01:26:05,167 They won't return my calls. I feel I have a responsibility to disclose this. They have not 966 01:26:05,167 --> 01:26:11,167 gotten back to us and so here are every one of Zoll's defib's supervisor creds for every one 967 01:26:15,458 --> 01:26:21,458 of their products lines. >> AUDIENCE MEMBER: We will have your CDs by the end of the day. 968 01:26:25,875 --> 01:26:31,875 >> Awesome! Here we go. There they are. Throw the CDs, there you go, 801234. So, vendors 969 01:26:35,917 --> 01:26:40,417 changing, yeah, they're getting better other than that one apparently won't reach out, so. 970 01:26:40,417 --> 01:26:44,500 All the baby care has reached out to us, we are working with them and I want to give a huge 971 01:26:44,500 --> 01:26:48,917 shoutout here to Philips really quick. I actually went in and worked with them completely pro 972 01:26:48,917 --> 01:26:53,000 bono, they invited me in to look at vulnerability disclosure and they have given me an official 973 01:26:53,000 --> 01:26:58,667 statement that they are going to work on this and so this is their positioning, they're going 974 01:26:58,667 --> 01:27:03,458 to come out with vulnerability disclosure policy. This is gonna be front and center for 975 01:27:03,458 --> 01:27:07,792 responsible disclosure on their website so that as a researcher you can actually go record these 976 01:27:07,792 --> 01:27:11,375 easily and even inside the healthcare organization so you don't have the disconnect with 977 01:27:11,375 --> 01:27:17,375 Biomed. So I want to give them a big hand for that. (Applause) So look for that because other 978 01:27:21,042 --> 01:27:26,042 organizations are gonna be doing that. And lastly, you know, how can you help us? If you are into 979 01:27:26,042 --> 01:27:30,417 Android iOS research, we want to look at application security and mobile device security, we are 980 01:27:30,417 --> 01:27:34,250 also looking with further collaboration on physicians and patients so if you're interested 981 01:27:34,250 --> 01:27:39,958 in that, you can get a hold of us. Finally, last, you know, greets to all these guys, you 982 01:27:39,958 --> 01:27:44,458 know, one for inspiring us, two for helping us out and collaborating with us, and you 983 01:27:44,458 --> 01:27:47,875 know, the federal agencies have been great. Support has been great there as well as you know, 984 01:27:47,875 --> 01:27:52,167 these two manufacturers, there's other manufacturers that are reaching out, not specifically 985 01:27:52,167 --> 01:27:57,375 on this talk but it's getting a lot better. So thank you guys for coming and have a good day! 986 01:27:57,375 --> 01:28:03,375 >> Thank you! (Cheers and applause)