1 00:00:00,000 --> 00:00:00,980 Good morning, everybody. 2 00:00:00,980 --> 00:00:03,400 My name is Jim Harris from PFP. 3 00:00:03,980 --> 00:00:07,180 Today I'm here with Carlos, our CTO. 4 00:00:07,280 --> 00:00:11,660 We're going to talk a little bit about side channel analysis for critical infrastructure protection. 5 00:00:12,400 --> 00:00:19,140 And since we're kind of early and we're starting a little bit early, feel free to interrupt with questions, whatever, as we're going along. 6 00:00:19,880 --> 00:00:22,940 And hopefully this will be an informative session. 7 00:00:27,260 --> 00:00:37,400 I hate standing behind a podium normally. 8 00:00:37,400 --> 00:00:43,480 I walk around when I'm talking, so this is... he's going to walk and I'll talk a little bit and then we'll switch. 9 00:00:54,460 --> 00:01:00,060 All right, this is a little bit easier for me because I have to pay some little ADHD. 10 00:01:00,060 --> 00:01:08,760 So what we're talking about is essentially using... we're trying to take a technology that was basically developed for the U.S. 11 00:01:08,760 --> 00:01:09,380 government, U.S. 12 00:01:09,380 --> 00:01:14,900 military, and our first commercial targets were in the ICS space. 13 00:01:14,900 --> 00:01:17,180 And the reason is because it's a similar use case. 14 00:01:17,180 --> 00:01:20,900 You have absolutely critical infrastructure that absolutely has to be protected. 15 00:01:21,000 --> 00:01:36,500 You have some things that cannot go down and you can't load software on them and you can't look at the network traffic and you can't do any of those things because we have a lot of this big divide between the focus of the OT, which is safety and security and availability of the system, 16 00:01:36,500 --> 00:01:40,340 and the focus of IT, which is trying to prevent compromises and breaches. 17 00:01:41,020 --> 00:01:44,860 And after... so I have a long, weird history. 18 00:01:44,860 --> 00:01:50,660 I won't go through the whole thing, but I spent... well, I started as an engineer back in the 1990s. 19 00:01:50,880 --> 00:01:58,000 I took a detour through the FBI for 11 years as a special agent, working mostly in cyber division and that type of stuff. 20 00:01:58,000 --> 00:02:11,040 And then I became a consultant, mostly back to the government, and did a lot of critical infrastructure protection cyber events in an effort to help people talk more intelligently about risk decisions. 21 00:02:11,040 --> 00:02:17,860 And IT and OT divide was a big part of my consulting business back in the day. 22 00:02:18,700 --> 00:02:32,020 Because this difference between how people view things, I mean, there's lots of different things you can go into about the psychological differences of how IT folks tend to think abstractly in terms of things like IP addresses and MAC addresses. 23 00:02:32,020 --> 00:02:37,400 OT guys tend to think concretely in things like mechanical processes and switches. 24 00:02:37,840 --> 00:02:47,660 And all the way through to the difference between a focus heavily on confidentiality and a focus almost entirely on availability and integrity. 25 00:02:47,920 --> 00:02:51,140 Right, so, can we go to the next one? 26 00:02:53,800 --> 00:02:55,060 Next one. 27 00:02:55,220 --> 00:02:56,240 There you go. 28 00:02:56,420 --> 00:02:57,140 Okay. 29 00:02:57,600 --> 00:03:01,460 So, the problem is, of course, that there's a shared deployment. 30 00:03:01,460 --> 00:03:03,960 In the old days, OT and the IT didn't meet. 31 00:03:04,580 --> 00:03:15,360 OT was on Modbus, serial ports, things like that, and IT was IP address, Ethernet, and they just didn't have a big connection. 32 00:03:15,360 --> 00:03:25,140 But now, everything including the Modbus has gone to Ethernet as well, and there's even wireless products that can be IP based as well. 33 00:03:25,840 --> 00:03:42,820 And we have this problem essentially of we have to make some decisions about systems that the folks who traditionally do IT technology don't necessarily understand what the system's doing or how to judge the context in which it's operating. 34 00:03:44,340 --> 00:03:45,500 Go ahead. 35 00:03:45,500 --> 00:03:50,240 So, let me give to the last point that Jim was talking about. 36 00:03:50,240 --> 00:03:54,860 So, there's been a lot of emphasis on using machine learning for security. 37 00:03:54,860 --> 00:04:08,480 And one of the main problems we have with machine learning is that, you know, that is the ground truth, which is once you're training your machine learning, you have to make sure whatever you claim is good is actually good, and whatever you claim is malicious is actually malicious. 38 00:04:08,500 --> 00:04:11,800 And there is a very blurry line between the two. 39 00:04:11,900 --> 00:04:15,940 So, coming up with that ground truth in the first place is very, very difficult. 40 00:04:15,940 --> 00:04:26,340 And the last one, when we talk about the endpoint paradox, is that most of the endpoint protection relies on actually installing agents on the devices themselves. 41 00:04:26,940 --> 00:04:31,680 And of course, that, you know, you need that endpoint information for context. 42 00:04:31,680 --> 00:04:35,940 If you're just looking at the network and you see a packet going through, you don't know what it did. 43 00:04:35,940 --> 00:04:36,800 You know, did it deploy? 44 00:04:36,800 --> 00:04:38,240 Did it do something bad to it? 45 00:04:38,240 --> 00:04:38,760 You don't know. 46 00:04:38,760 --> 00:04:44,300 You need to have that endpoint context to really understand what's going on with your network, with your whole system. 47 00:04:44,300 --> 00:04:50,260 But in order to get that context, you need, usually, you need to install an agent in the endpoint itself. 48 00:04:50,580 --> 00:04:55,540 Which means that it's a little bit like asking, you know, the fox having a chicken in the hen house. 49 00:04:55,540 --> 00:05:01,740 Because the moment somebody compromises that endpoint, you know, they can make the agent lie to you. 50 00:05:01,820 --> 00:05:07,380 So we have that paradox that we call it because you need to rely on the endpoint, but you cannot trust it. 51 00:05:12,200 --> 00:05:18,960 Alright, so a lot of the things that people do today, which are trying to separate the systems from the internet, good. 52 00:05:18,960 --> 00:05:20,200 Patching, good. 53 00:05:20,200 --> 00:05:23,360 But difficult if you've separated the system from the internet. 54 00:05:24,180 --> 00:05:32,680 Using these kind of traditional IT systems, they're all, you know, things that are necessary, but not complete, right? 55 00:05:32,680 --> 00:05:35,440 They don't actually solve the essential problem. 56 00:05:35,520 --> 00:05:42,020 They also don't necessarily solve the fundamental insider problem that everybody kind of understands they now face. 57 00:05:45,000 --> 00:05:58,340 With this, you know, sorry, let me go back to Carlos because there was something about the limited operations that he put in here that I wasn't sure about. 58 00:05:58,340 --> 00:06:03,860 Right, yeah, so, like Jim said, IT and OT are very different. 59 00:06:03,860 --> 00:06:12,180 Most of the time, when you're talking about security, you bring the things that we learn in the IT world, we try to jam them into the OT world, and they're very different worlds. 60 00:06:12,180 --> 00:06:18,220 There's one quick example that, you know, for Windows updates, the best time to do it is on a Sunday at 2 a.m. 61 00:06:18,220 --> 00:06:20,520 in the morning, when it's not disrupting anybody. 62 00:06:20,520 --> 00:06:28,440 That would be the absolute worst time to do it in an OT system, because if something goes wrong, you want to have everybody looking at it so they can take action. 63 00:06:28,440 --> 00:06:30,100 So they're very, very different. 64 00:06:30,340 --> 00:06:38,840 And when you try to jam the security solutions from IT into the OT, you leave some systems vulnerable because not all of them can be deployed. 65 00:06:39,680 --> 00:06:46,780 So you have, in addition to that, a lot of the operational requirements that are very strict, very different from OT systems. 66 00:06:46,780 --> 00:06:56,160 You have embedded systems, you have legacy devices, you have a broad variety of platforms that have to interact, and where reliability is king. 67 00:06:56,160 --> 00:07:04,180 So it makes it really difficult to use the things that we have learned in the IT world to directly just apply them in the OT. 68 00:07:05,400 --> 00:07:09,140 So, yeah, that's what we were trying to say in this one. 69 00:07:09,140 --> 00:07:21,400 Yeah, and to that end, I kind of remembered, I sort of blanked there for a second, but I had an interesting two different consulting engagements, and of course I can't mention the companies involved, but both of them were utilities. 70 00:07:21,980 --> 00:07:26,400 And one of the utilities proudly said, we solve all of our problems with air gaps. 71 00:07:26,400 --> 00:07:29,720 And then they went on to describe, I said, okay, so it's truly air gapped. 72 00:07:29,720 --> 00:07:33,080 And they said, yeah, absolutely air gapped, this is a power supply system. 73 00:07:33,400 --> 00:07:41,520 I said, okay, so your billing of the energy, right, how does that get to your, your billing department? 74 00:07:41,520 --> 00:07:46,660 They said, oh, well it just, you know, goes through the firewall and the MPLS to the business system, something. 75 00:07:47,400 --> 00:07:48,980 But that's not an air gap. 76 00:07:49,500 --> 00:07:51,300 No, it's like an air gap. 77 00:07:52,360 --> 00:07:53,880 But it's not an air gap. 78 00:07:53,880 --> 00:08:05,600 And it was just kind of funny that we, as we were having this discussion, they, they really genuinely, truly thought they had air gapped the system by putting a firewall and MPLS through the firewall. 79 00:08:05,980 --> 00:08:11,640 I had another company that really, truly, they were, as far as I could tell, air gapped, right? 80 00:08:11,640 --> 00:08:15,640 They had completely severed any IP connection into the system. 81 00:08:15,640 --> 00:08:16,360 Cool. 82 00:08:17,020 --> 00:08:18,480 How do you update the firmware? 83 00:08:18,480 --> 00:08:23,860 Oh, we go over to the internet machine, download the firmware, put it on a thumb drive, walk over to the machine and load it. 84 00:08:24,360 --> 00:08:28,240 Okay, technically an air gap, but obviously another vector. 85 00:08:28,240 --> 00:08:36,000 And since they had no other software on the system to protect it or any other device to protect it because, hey, we're air gapped, what could possibly go wrong? 86 00:08:36,060 --> 00:08:40,600 They were doing that, which post-Duxnet everybody knows doesn't work. 87 00:08:41,620 --> 00:08:45,140 So what we're looking at instead is something a little bit different. 88 00:08:45,140 --> 00:08:55,600 So the challenge here, of course, is to put something that doesn't require loading software, interrupting the network, or could possibly become a point of failure for the entire system. 89 00:08:55,980 --> 00:09:04,780 So PFPs, what we've been researching and doing for quite some time in the government space is looking at side-channel analysis. 90 00:09:04,780 --> 00:09:19,540 Now, everybody at the conference has probably heard somebody talk about side-channel analysis, talking about reading RSA keys or breaking or doing bad things to a system, but we're kind of the other side of this, which is we want to use the same process. 91 00:09:19,540 --> 00:09:35,500 We want to look at tiny fluctuations on either the power or the EM emissions to determine what the state of the system is, if it's in a known good state, a known bad state, or an unknown state, which in this type of application should be considered bad. 92 00:09:35,500 --> 00:09:53,040 So if you think about the power plane inside of an electrical device, right, like our badges and everything like that, each time a processor , microcontroller, whatever, has to make an operation, has to do something at a clock cycle, even if it's negligible, 93 00:09:53,040 --> 00:09:57,080 it has to reach into that power plane, it has to pull some power out. 94 00:09:57,280 --> 00:10:08,160 So if you think about that as a very still, crystal still lake, right, like Lake Tahoe in the summer, you know, looks really clear, you almost don't want to touch it, because as soon as you touch it, you know you're going to create ripples. 95 00:10:08,160 --> 00:10:12,020 Those ripples are going to go on smaller and smaller, but indefinitely. 96 00:10:12,620 --> 00:10:30,420 If you think about a deterministic process like an industrial control system reaching in, dipping into that power plane over and over again, it creates very patternistic, patternistic is not a word I'm sure, but deterministic patterns of waves on that plane. 97 00:10:30,760 --> 00:10:47,480 So we're using, usually in EM in these cases, and we'll talk about why, we're using that, along with some signal processing and machine learning to basically identify, in time and frequency space, what are those things that are important between the different operating states. 98 00:10:47,620 --> 00:10:55,660 And then outputting a statistical fit of what state you're in, the machine thinks you're in, and how confident it is in that state. 99 00:10:55,720 --> 00:10:57,060 Is there anything you wanted to add? 100 00:10:57,100 --> 00:10:59,160 No, no, that's really it. 101 00:10:59,160 --> 00:11:14,000 No, there's a lot of signal processing involved, so when we start talking to people about, you know, side channels and transforms and wavelet transforms and things like that, often they don't, the traditional cyber people, they have a little hard time wrapping their heads around it, 102 00:11:14,000 --> 00:11:16,720 but in principle it's very, very straightforward. 103 00:11:16,900 --> 00:11:26,340 You know, when you have a digital device, you're flipping bits from 1 to 0 to 1, and the more bits they flip in every clock cycle, the more energy you need to flip those bits. 104 00:11:26,360 --> 00:11:34,000 So as you're executing your logic, you're flipping more or less bits, it gives you this very tiny but very unique pattern that depends upon the hardware and the software. 105 00:11:34,040 --> 00:11:35,360 And that's the one we're going. 106 00:11:35,360 --> 00:11:38,700 The people doing side channel attacks, they go after that to steal information. 107 00:11:38,700 --> 00:11:44,660 We're flipping around and we're using it to make sure that nobody has modified the logic in your device. 108 00:11:48,990 --> 00:11:57,970 And, oh yeah, this is the slide, the next slide, that we'll see in a minute, is one that for some reason takes a long time to load on this computer. 109 00:11:58,750 --> 00:12:02,450 But let me talk about it a little bit while these are loads. 110 00:12:02,450 --> 00:12:03,510 Oh, yeah, sure. 111 00:12:09,900 --> 00:12:17,000 So the training right now, and actually our current setup is actually based, so I should probably talk about it more. 112 00:12:17,200 --> 00:12:19,640 The machine learning training, we got a couple of different paths. 113 00:12:19,640 --> 00:12:27,400 One is the original machine learning algorithms that Carlos, as part of his PhD work, developed some time back. 114 00:12:27,400 --> 00:12:30,600 And that has been developed into what we're currently using. 115 00:12:30,660 --> 00:12:35,880 I'm also doing some work now in deep learning, convolutional neural networks, to do the same thing. 116 00:12:35,880 --> 00:12:48,020 So less signal processing up front, more deep learning, which obviously takes more processing power, but can get better separation in some odd cases, some difficult cases. 117 00:12:48,300 --> 00:12:50,680 But that's still kind of under development. 118 00:12:51,480 --> 00:12:55,200 But Carlos can talk more about his work, because... 119 00:12:55,200 --> 00:12:57,760 Yeah, so my background is in wireless communications. 120 00:12:57,760 --> 00:12:59,980 I used to work with self-defined radios. 121 00:12:59,980 --> 00:13:10,000 And the origin of the technology, it was looking at how to help regulatory bodies certify self-defined radios and enforce those certifications. 122 00:13:10,080 --> 00:13:18,900 When the FCC tests a new radio and puts a stamp of approval that can be sold, they certify a specific hardware with a specific software, it's a pair. 123 00:13:18,900 --> 00:13:22,880 And if you change either one of them, you have to go get retested to get re-certified. 124 00:13:22,880 --> 00:13:26,100 But they never said how they were going to enforce that. 125 00:13:26,100 --> 00:13:32,760 So that was part of the work that we were doing in figuring out how can we help, how can we detect that either one of them has changed. 126 00:13:32,780 --> 00:13:37,480 Of course, we look at such channels, they worked, and the application for cybersecurity was straightforward. 127 00:13:37,680 --> 00:13:43,240 In terms of the training, we have a battery, like Jim was saying, we have a battery of different machine learning algorithms. 128 00:13:43,280 --> 00:13:51,640 And they go from the traditional, the support vector machines, random forests, just Bayes classifiers. 129 00:13:51,640 --> 00:13:56,060 And we're doing a lot of work lately with deep learning and just giving really good results. 130 00:13:56,060 --> 00:13:58,420 And all of them work in different cases. 131 00:13:58,420 --> 00:14:08,100 So we have a battery of them, we do a lot of feature extraction ahead of time, a lot of signal processing to clean the signals, synchronize them, and clean them up. 132 00:14:08,100 --> 00:14:10,400 And then, you know, we pass them to the classifiers. 133 00:14:10,780 --> 00:14:19,720 A lot of our work is part of a DARPA project on using AI to classify signals in different areas has fed this. 134 00:14:19,720 --> 00:14:23,140 So we're kind of finding what are the best things to work on different use cases. 135 00:14:23,740 --> 00:14:31,580 Because different machine models have different accuracies, depending upon the signal, you know, different parts of the signal. 136 00:14:31,580 --> 00:14:35,280 In fact, we still don't fundamentally understand why some things work better. 137 00:14:35,280 --> 00:14:44,280 And that's part of what we're doing now as fundamental research is, can we figure out why certain machine learning algorithms work better on certain types of signals and not on others? 138 00:14:44,300 --> 00:14:48,520 And, you know, that's, there's still a lot of fundamental questions to be answered about that. 139 00:14:48,520 --> 00:14:51,360 So went to finally loaded the slide. 140 00:14:51,460 --> 00:14:59,480 And one of the things that when we tell people that we look at side channels, usually a PFP stands for power fingerprinting, we often look at power consumption of the devices. 141 00:14:59,540 --> 00:15:06,360 People often think, oh, let me see the level of power in my cell phone, like the battery indicator. 142 00:15:06,420 --> 00:15:08,760 And that's not what we look at. 143 00:15:08,760 --> 00:15:11,260 We look at tiny, tiny patterns. 144 00:15:11,880 --> 00:15:13,160 This is what they look like. 145 00:15:13,160 --> 00:15:14,940 That's one of the traces from a PLC, actually. 146 00:15:14,940 --> 00:15:16,680 This is what they actually look like. 147 00:15:17,080 --> 00:15:23,740 And if you see the picture of the chip, the emissions radiating directly from the silicon. 148 00:15:23,740 --> 00:15:26,980 This is part of the fundamental physics of the semiconductor. 149 00:15:27,100 --> 00:15:30,300 See, as you're moving electrons around, they generate those fields. 150 00:15:30,900 --> 00:15:33,000 And we're the ones, those are the ones where we're picking up. 151 00:15:33,000 --> 00:15:34,900 Because we tell people often, oh, we're looking at power. 152 00:15:34,900 --> 00:15:39,420 You're looking at how much, you know, what if I turn my screen on? 153 00:15:39,420 --> 00:15:40,360 Or what if I turn a fan? 154 00:15:40,360 --> 00:15:41,560 That's gonna mess you up. 155 00:15:41,560 --> 00:15:47,640 No, we're looking at the emissions directly from the processor that it's executing your logic. 156 00:15:48,000 --> 00:15:50,380 So it's a, it's a different concept. 157 00:15:50,380 --> 00:15:55,660 No packets, no, uh, system calls, um, yeah. 158 00:15:55,660 --> 00:15:58,500 And one of the things about, uh, this part right here. 159 00:15:58,500 --> 00:16:03,680 So if you go see our demo in the next area, you'll see that we have a very tiny little loop antenna. 160 00:16:04,080 --> 00:16:11,600 That little loop antenna is mostly going to pick up, because a question commonly comes up, uh, well, isn't that subject to a whole lot of noise? 161 00:16:11,600 --> 00:16:18,040 But the type of probe that you'll see there is mostly picking up the magnetic component of the, of the EM emissions, right? 162 00:16:18,040 --> 00:16:22,840 So it doesn't, that drops off very rapidly, uh, with distance. 163 00:16:22,840 --> 00:16:26,500 So it's much, you know, more accurate when we use the EM. 164 00:16:26,500 --> 00:16:34,280 We also have, uh, some demos where there were, uh, some installed on the wall where you see it's using DC power, which is also pretty good. 165 00:16:34,280 --> 00:16:40,380 Um, not always in an ICS if it's in line, because then potentially we could become a point of failure for the system. 166 00:16:40,380 --> 00:16:50,800 But the EM is really, really good and works well in a noisy environment, because we're mostly measuring that, the B, the magnetic field component of the EM field. 167 00:16:53,660 --> 00:16:57,840 So, so we, we talk already about side channel, uh, uh, attacks. 168 00:16:58,000 --> 00:17:04,500 And the Tempest, you probably guys are familiar with, the Tempest was designed specifically, uh, for those side channels. 169 00:17:04,500 --> 00:17:12,580 So when we, you know, if you're familiar with those, you know, you know that they haven't used for decades to extract that information, which is using it in a slightly different way. 170 00:17:12,660 --> 00:17:20,480 And if you see the racks and stuff that goes in there for a Tempest system, that's what you have to do to prevent the signal from leaking out. 171 00:17:20,820 --> 00:17:21,760 Oh, go ahead. 172 00:17:33,630 --> 00:17:34,350 Right. 173 00:17:34,530 --> 00:17:37,210 Whether it's malicious or not. 174 00:17:39,190 --> 00:17:39,790 That's right. 175 00:17:39,790 --> 00:17:42,330 So, so basically that would be the, the case of jamming, right? 176 00:17:42,330 --> 00:17:48,510 If, if somebody would be jamming you with a, with a, with a magnet, uh, or with anything else. 177 00:17:48,510 --> 00:17:54,470 So we, you would see it, you would see, oh, there's this big jam and, and we will flag it and somebody would have to go look at it. 178 00:17:54,470 --> 00:17:59,030 But it would be very obvious that you're being jammed in the signal. 179 00:18:07,820 --> 00:18:08,640 That's true. 180 00:18:08,640 --> 00:18:09,220 That's true. 181 00:18:09,220 --> 00:18:11,520 They could be just working with magnets. 182 00:18:14,880 --> 00:18:15,420 Right. 183 00:18:15,420 --> 00:18:17,340 It is possible, but it's very unlikely. 184 00:18:17,340 --> 00:18:20,000 So we were actually, we were doing some tests in a, in a substation . 185 00:18:20,000 --> 00:18:24,420 They have these big, massive, massive transformers right next to it. 186 00:18:24,640 --> 00:18:28,800 And you can see that , you know, there's this huge electromagnetic fields around it. 187 00:18:28,940 --> 00:18:36,520 And they actually, when you go there, they, they ask you, they, no metal, you have to, you have to put your suit to, to, to be able to get there. 188 00:18:36,520 --> 00:18:47,300 And, and this one works just fine because, you know, at that point it becomes, um, you increase a little bit the noise and the, the, the, uh, the signals come at different spectral bands. 189 00:18:47,300 --> 00:18:49,520 So you can filter those fairly easily. 190 00:18:50,040 --> 00:19:02,060 And, and if somebody doesn't say, if somebody were going to be playing with a magnet right next to your device and doing this, like, you know, at several kilohertz moving it, well that could probably, you know, impact us, but very unlikely. 191 00:19:02,240 --> 00:19:02,400 Yeah. 192 00:19:02,400 --> 00:19:10,040 A static magnet, the, the delta of the, or the change from moment to moment of the magnetic field isn't going to really register. 193 00:19:10,040 --> 00:19:11,080 It's the delta. 194 00:19:11,080 --> 00:19:17,720 So if you're moving the magnet rapidly in and out, if you do it, you know, 10,000 times a second, then it would definitely make a field. 195 00:19:17,860 --> 00:19:20,600 And a lot of the magnetic fields we would be around might be static. 196 00:19:21,400 --> 00:19:21,620 Yeah. 197 00:19:22,660 --> 00:19:23,180 Yeah. 198 00:19:23,180 --> 00:19:25,120 I mean, exactly. 199 00:19:25,120 --> 00:19:27,000 It, it is potentially there. 200 00:19:27,020 --> 00:19:34,380 That's part of the reason when you're doing the baseline, the machine learning, you should do it in as much as possible in the environment in which it's going to be deployed. 201 00:19:34,380 --> 00:19:41,320 So as close to that environment as possible so that the machine can already learn what the ambient noise that it might pick up looks like. 202 00:19:44,640 --> 00:19:57,860 Integrity assessments, again, what we're essentially doing is trying to look at, once we have built a model of it, we're looking through those side channel patterns, we have our baseline, we measure distance from the baseline to what we're seeing right now, 203 00:19:57,860 --> 00:20:03,200 and then give you a confidence level out of, this is the state I'm in, this is my confidence level. 204 00:20:03,200 --> 00:20:11,500 If the confidence level gets too far outside of what is acceptable, then, and it doesn't match any other state, then it's an anomaly. 205 00:20:11,500 --> 00:20:17,320 And I don't know what it is, I can't help you figure that out, but I can absolutely tell you that it's not operating exactly the same way. 206 00:20:17,400 --> 00:20:22,900 It could be because of an electrical failure, it could be because somebody's doing something with electromagnetic fields nearby. 207 00:20:22,940 --> 00:20:27,960 I don't know what it is, I just know I'm not in the right operating condition that you expect me to be in. 208 00:20:30,360 --> 00:20:31,080 Okay. 209 00:20:31,320 --> 00:20:32,880 This one I have to turn it down. 210 00:20:32,900 --> 00:20:36,700 So there's two ways in which we normally do the training. 211 00:20:36,700 --> 00:20:41,900 The way that we prefer, that we prefer, is when we do the supervised learning. 212 00:20:41,900 --> 00:20:52,620 And which means is that you grab your device that you're going to be monitoring, and you bring it to your test and evaluation room, and you make it go through all the different phases, go through all the different states. 213 00:20:52,620 --> 00:21:00,420 This is the exact same type of assessment that you would do to do code coverage on your traditional functional tests. 214 00:21:00,600 --> 00:21:04,700 So you want to exercise all the different paths, doesn't mean you have to exercise all the different inputs. 215 00:21:04,700 --> 00:21:16,580 You have to exercise all the different execution paths, and that way you can come up with a complete library of what the normal, the real states are. 216 00:21:16,580 --> 00:21:19,640 And then if anything were to come in, we will flag it. 217 00:21:19,780 --> 00:21:28,440 Of course, that requires you to have a test and evaluation room, and that you can able to monitor for the execution of different states. 218 00:21:28,900 --> 00:21:36,480 The other one is unsupervised learning, where you simply observe the device for a period of time, and whatever you observe in that time, you make it part of your library. 219 00:21:37,180 --> 00:21:41,840 And they might, anything you don't see, you can match it, you flag it. 220 00:21:41,840 --> 00:21:47,980 But in that case, we can have more false positives, because we haven't seen all the states. 221 00:21:48,080 --> 00:21:51,560 And people often ask us, well, how about complex platforms? 222 00:21:51,560 --> 00:21:55,520 You have a really, really complex device, and PLCs are actually fairly complex. 223 00:21:55,880 --> 00:21:58,260 And what we tell them is we limit the scope of those. 224 00:21:58,260 --> 00:22:09,580 We either force them to execute a specific task, and we make sure that that task hasn't been compromised, or we go low-level and make sure that the firmware and the initial execution, the BIOS, hasn't been tampered with. 225 00:22:10,120 --> 00:22:11,660 So let me go to the next one. 226 00:22:11,940 --> 00:22:16,080 So one of the things people ask about the performance is how well it does. 227 00:22:16,220 --> 00:22:22,660 This is one of the early work we did with DARPA, and it shows the ROC, Receiver Operating Characteristic Curve. 228 00:22:22,660 --> 00:22:27,600 Basically, it's how good a detector is, how well a detector works. 229 00:22:27,980 --> 00:22:31,280 And so vertical axis is probability of detection. 230 00:22:31,280 --> 00:22:41,760 When you have an anomaly, something else, you detect it, versus a false positive, which is when you have a real legitimate event that you've mistaken flag it as an anomaly. 231 00:22:41,760 --> 00:22:53,060 And in this case, you see that for the blue line, for over 80% probability of detection, you have a 10 to the minus 15 false positive rate. 232 00:22:53,060 --> 00:22:59,840 And the reason why we can do that, you see the three lines, is because with PFP, it works differently. 233 00:22:59,840 --> 00:23:06,920 If you were to send a file to VirusTotal and get your assessment, it will tell you malicious, not malicious, whatever. 234 00:23:07,100 --> 00:23:13,080 If you send the same packet 1,000 times, or the same file 1,000 times, you get the same answer 1,000 times. 235 00:23:13,080 --> 00:23:18,280 With PFP, you observe one execution instance, and you give you an assessment, which is the black line. 236 00:23:18,380 --> 00:23:27,420 If you can observe another execution instance of the same code, you can put them together and start integrating the noise out, so you get a cleaner signal. 237 00:23:27,420 --> 00:23:30,060 The more you observe, the cleaner the signal it gets. 238 00:23:30,060 --> 00:23:34,180 So that's why we can come up with this such low probability of false positives. 239 00:23:35,100 --> 00:23:36,540 Works differently. 240 00:23:42,440 --> 00:23:54,200 So one of the reasons people do this is, you know, doing assessment using side channels, integrative side channels, is much harder than just asking the device, hey, you know, are you okay? 241 00:23:54,580 --> 00:23:58,120 But there's a lot of advantages of doing it this way. 242 00:23:58,120 --> 00:24:00,760 And the main one is that we do no harm. 243 00:24:00,760 --> 00:24:06,260 So normally, like we've talked before, we have that line between the OT and the IT, the safety critical side. 244 00:24:06,260 --> 00:24:09,080 You have to make sure you do no harm to those systems. 245 00:24:09,080 --> 00:24:17,540 And with PFP, because you can be physically separated from them, you can physically air gap from it, you guarantee you do no harm. 246 00:24:18,060 --> 00:24:22,740 There's no latency or reliability impact on your network or on your device itself. 247 00:24:22,740 --> 00:24:26,740 And you're literally just putting a probe right next to it. 248 00:24:26,880 --> 00:24:32,740 You can, because we look at them as signals, we don't care what the box that generated them there. 249 00:24:32,740 --> 00:24:34,600 So we look at them as black boxes. 250 00:24:34,780 --> 00:24:41,280 You can support embedded legacy devices , can be real-time systems, and we add no latency to them. 251 00:24:41,280 --> 00:24:43,520 So there's no need to re-certification. 252 00:24:43,520 --> 00:24:52,520 A lot of critical infrastructure plants, they have to go through a very rigorous certification process to make sure that they don't, you know, explode and kill people. 253 00:24:53,040 --> 00:25:00,500 So every time you're going to introduce a change in any of those systems, it can be very expensive to go through and do the whole re-certification. 254 00:25:00,500 --> 00:25:08,660 With PFP, since you're not changing any of that, by using side channels and you're not changing any of the system, you avoid all that complex process. 255 00:25:09,160 --> 00:25:12,580 And very importantly, it does not introduce additional vulnerabilities. 256 00:25:12,640 --> 00:25:18,560 Something like 30% of attack vectors, don't remember the actual numbers, come from actually, you know, security solutions. 257 00:25:18,560 --> 00:25:25,840 With PFP, again, you are separated from it, so you introduce no additional vulnerabilities to your system. 258 00:25:26,480 --> 00:25:29,060 And you can detect that very quickly. 259 00:25:29,060 --> 00:25:32,840 And the last one that we have here is very robust against evasion. 260 00:25:32,840 --> 00:25:42,900 Technically, it's possible for somebody to generate a sequence of code that matches perfectly what the other code was doing, but it's very, very difficult. 261 00:25:42,900 --> 00:25:45,400 Technically possible, but it's very, very difficult. 262 00:25:45,520 --> 00:25:47,340 And also covers accidental faults. 263 00:25:47,340 --> 00:25:52,900 So if for some reason you have this gamma ray that hits your system and it's definitely behaving, we will catch that as well. 264 00:25:52,920 --> 00:25:58,780 And it's not a malicious attack, but it's something that you need to know because you're dealing with critical infrastructure. 265 00:25:59,340 --> 00:26:05,780 It integrates with any other solution, so you can, you don't have to modify any of your system, including your security solutions that you have in place. 266 00:26:05,780 --> 00:26:09,900 You can have your access controls, you can have firewalls, anything else you want. 267 00:26:09,900 --> 00:26:12,060 We just put an additional layer of protection. 268 00:26:12,660 --> 00:26:20,640 And because we're air-gapped from it, if you compromise the device, the target device that we're monitoring, you cannot get from there to us. 269 00:26:20,640 --> 00:26:23,920 And if you compromise us, you cannot get to them. 270 00:26:24,400 --> 00:26:32,400 Yeah, and again, to this point about adding a layer, so we're obviously not sitting here saying that, you know, this is the only way you should monitor the device. 271 00:26:32,400 --> 00:26:34,200 There are lots of other things you should be doing. 272 00:26:34,200 --> 00:26:35,960 This is just an additional checkpoint. 273 00:26:36,220 --> 00:26:46,400 When you get to the idea of what we can detect, again, at the end of the day, if the function gets weird, which could be because it's failing or could be because somebody's attacking it, all we can tell you is that it's weird. 274 00:26:46,400 --> 00:26:50,840 We can't tell you that it's, you know, malicious or we can't, you know. 275 00:26:51,080 --> 00:27:04,680 In some limited circumstances with other types of devices, we have categorized things like Mirai on cameras and things like that, so we have known bad states that we can characterize, but there's too many of those and there's enough people in that area doing that type of stuff. 276 00:27:04,680 --> 00:27:08,880 We focus more on making sure that the hardware is what you expect it to be. 277 00:27:11,310 --> 00:27:13,090 So, it's time? 278 00:27:13,090 --> 00:27:13,690 Okay. 279 00:27:13,690 --> 00:27:19,750 Well, this was a very interesting live, but we spent too much time at the beginning, so we'll keep it. 280 00:27:19,870 --> 00:27:21,350 Let's just wrap it up. 281 00:27:21,950 --> 00:27:25,650 There's DARPA project that is funding us to do this work. 282 00:27:25,890 --> 00:27:28,110 And there's basically two deployment options. 283 00:27:28,110 --> 00:27:34,190 You can deploy the technology runtime or you can deploy the technology as a screening. 284 00:27:34,430 --> 00:27:39,010 So, if you create an infrastructure, you want to make sure that your devices haven't been, the hardware hasn't been compromised. 285 00:27:39,090 --> 00:27:43,250 You can tailor the tools to do that or you want to make sure continuous monitoring. 286 00:27:43,250 --> 00:27:51,350 And when we say continuous, you know, we really mean 24-7, you know, every second making sure that the execution of your system hasn't been compromised. 287 00:27:51,470 --> 00:27:53,650 So, we have those two deployment options. 288 00:27:53,990 --> 00:27:55,950 We've done tests with PLCs. 289 00:27:55,950 --> 00:27:58,670 You can come to our next door to see our demo. 290 00:27:58,670 --> 00:28:02,850 We've done tests with Cisco routers, network infrastructure, a number of platforms. 291 00:28:03,190 --> 00:28:06,750 So, with that, I'll let Jim, you know, wrap it up. 292 00:28:06,850 --> 00:28:09,230 Yeah, so again, we'll wrap up quickly. 293 00:28:09,230 --> 00:28:15,470 We don't want to go over time and, you know, respectful of the next speakers that are going up, but please come see it. 294 00:28:15,590 --> 00:28:17,810 Think about this and other applications of this. 295 00:28:17,810 --> 00:28:26,450 We're still, you know, kind of in that transition stage between research and government and DoD research and like practical applications. 296 00:28:26,450 --> 00:28:32,010 So, I'd love to hear your ideas, thoughts you might have on it, and look forward to talking to all of you. 297 00:28:32,010 --> 00:28:33,070 Thanks very much. 298 00:28:33,670 --> 00:28:34,570 Thank you.