1 00:00:01,200 --> 00:00:03,280 Next speaker up is Mike Godfrey. 2 00:00:03,280 --> 00:00:10,540 He's going to talk about how we cost our client 1.2 million pounds, with four lines of code, and less than two hours. 3 00:00:10,540 --> 00:00:12,900 So, give a round of applause for Mike. 4 00:00:20,020 --> 00:00:20,780 Hello. 5 00:00:21,240 --> 00:00:22,560 Well, thanks a lot for coming. 6 00:00:22,760 --> 00:00:27,280 We've got a lot to get through in a short amount of time, so we'll get straight into it. 7 00:00:28,240 --> 00:00:30,600 As you heard on Mike, I'm at Mike G Hacks. 8 00:00:30,720 --> 00:00:32,000 I'm the founder of Insinia. 9 00:00:32,000 --> 00:00:33,080 I'm a qualified pen tester. 10 00:00:33,080 --> 00:00:34,980 I'm qualified CCNA, CEH. 11 00:00:34,980 --> 00:00:38,280 I spent ten years in priority, about 23 years in breaking it. 12 00:00:38,740 --> 00:00:43,700 I specialise in hardware and physical, and I'm a qualified commercial and industrial electrician and gas engineer. 13 00:00:43,700 --> 00:00:46,360 So, I actually started out in ICS as a commercial gas engineer. 14 00:00:47,160 --> 00:00:50,860 To tell you a quick few bits about this talk, we carry out impact-based pen testing. 15 00:00:50,860 --> 00:00:53,680 So, you're not going to see Nessus scans, you're not going to see that sort of output. 16 00:00:53,960 --> 00:00:55,660 We take on about ten clients a year. 17 00:00:55,660 --> 00:01:01,280 So, people that come to us really want to know the true impacts of what's going to happen in their systems. 18 00:01:01,400 --> 00:01:05,560 I usually give this talk to my colleague Paul Hunter, who couldn't be here, but my colleague Simon is. 19 00:01:05,780 --> 00:01:06,560 So, ask me anything. 20 00:01:06,560 --> 00:01:12,800 Simon's also outside of a PLC, and we're going to talk about how to lose 1.2 million pounds in two hours, about $2 million. 21 00:01:13,480 --> 00:01:17,600 So, to tell you a bit about us, we're probably the UK leaders in ICS security training. 22 00:01:17,680 --> 00:01:21,960 We've got a 16,500 square foot lab that's got loads of legacy technology. 23 00:01:22,160 --> 00:01:24,980 It's got all the main manufacturers, Siemens, Omron, Allen-Bradley, etc. 24 00:01:25,340 --> 00:01:28,140 We're the only gas-safe cybersecurity company in the UK. 25 00:01:28,180 --> 00:01:29,600 We'll talk about why that's relevant in a minute. 26 00:01:29,820 --> 00:01:33,700 We've got 10 years' experience in attacking ICS, and we're a city and goods-free training centre. 27 00:01:34,180 --> 00:01:36,380 This is a couple of pictures of our lab. 28 00:01:36,400 --> 00:01:39,100 So, this is one area, a spoiling plant and a gas rig. 29 00:01:39,280 --> 00:01:44,000 This is one of our robotic arms, an ABB, and this is one of our gamification rigs. 30 00:01:44,200 --> 00:01:46,460 Here, we've got a short video that shows you a bit about what we do. 31 00:03:10,770 --> 00:03:12,570 So, I say we're gas-safe registered. 32 00:03:12,570 --> 00:03:13,490 What does that actually mean? 33 00:03:13,490 --> 00:03:16,810 Well, gas appliances in the UK, this is a typical domestic appliance. 34 00:03:17,010 --> 00:03:19,190 It's from about 24 to 40 kilowatt. 35 00:03:19,190 --> 00:03:22,570 When we're talking about gas systems, what we're actually talking about is things like this. 36 00:03:22,570 --> 00:03:25,530 So, things that are up to 70,000 kilowatt, 70 megawatt. 37 00:03:25,650 --> 00:03:28,570 So, when we talk about gas throughout this talk, this is really what we're talking about. 38 00:03:28,770 --> 00:03:31,310 Now, to talk about a few things on SCADA. 39 00:03:31,630 --> 00:03:33,510 Firstly, SCADA is probably not what you think. 40 00:03:33,510 --> 00:03:35,070 There is an industrial control system. 41 00:03:35,070 --> 00:03:37,650 So, a better description would really be control system. 42 00:03:37,690 --> 00:03:41,410 The Bellagio fountains are under control system, similar sorts of things. 43 00:03:41,430 --> 00:03:46,010 But these cover everything from industrial process, military equipment, transportation. 44 00:03:46,110 --> 00:03:49,510 In fact, this is what people, most people, accept as SCADA. 45 00:03:49,550 --> 00:04:00,270 But it's prevalent in transportation, in electric, in healthcare, in water, building management systems, in natural gas, in oil, in chemical, manufacturing. 46 00:04:01,330 --> 00:04:03,310 So, it's the problem with securing all these things. 47 00:04:03,310 --> 00:04:08,010 Now, this is an image from Joe Weiss and basically it outlines the problem perfectly. 48 00:04:08,010 --> 00:04:15,430 Now, the issue is that you've got ICS engineers who haven't really integrated properly with IT and you've got IT security specialists who don't really understand the engineering side of it. 49 00:04:15,550 --> 00:04:22,030 On that basis, it's very, very difficult to work out what is a cyber attack and what is a cyber failure, because there's a massive skills gap. 50 00:04:22,250 --> 00:04:24,750 Um, when these failures happen, they almost cause wars. 51 00:04:24,750 --> 00:04:25,890 We'll talk about that in a minute. 52 00:04:25,890 --> 00:04:28,910 And the RAF in the UK are still installing their 7300s. 53 00:04:28,910 --> 00:04:30,370 It's a really old technology. 54 00:04:30,790 --> 00:04:43,070 If you have a look at the problem with that technology, it's old technology, it's insecure by design, it's cross protocol, you've got secure level 1 to level 3 devices, so you've got insufficient backups, which is a big problem, because if you drop the power to an old PLC, 55 00:04:43,070 --> 00:04:45,170 then it deletes the program, drops the program. 56 00:04:45,250 --> 00:04:47,170 So without proper backups, a big issue. 57 00:04:47,190 --> 00:04:52,690 But because these are such good pieces of kit and are so reliable, they don't really warrant a full-time on-site technical facility. 58 00:04:52,790 --> 00:04:55,510 So there really isn't ICS engineers on every single location. 59 00:04:55,650 --> 00:04:57,610 And there's a lack of ICS security experts. 60 00:04:57,910 --> 00:05:01,010 Now, to fly through these, as I've said, we're quite short on time. 61 00:05:01,190 --> 00:05:04,550 These are really easy to access, that's why they're not great for hackers. 62 00:05:04,690 --> 00:05:06,050 They've got little or no security. 63 00:05:06,050 --> 00:05:08,850 They've got default hard-coded credentials quite often. 64 00:05:09,110 --> 00:05:13,090 And it should really say there's no protection from physical attacks, because there really isn't. 65 00:05:13,390 --> 00:05:16,330 There's almost no traceability of forensic evidence when these are attacked. 66 00:05:16,450 --> 00:05:19,930 They're very easy to attack remotely, and there's a range of attack vectors at all levels. 67 00:05:20,370 --> 00:05:24,910 And when we have a look at the types of attack that we see on these, ransomware and DDoS aren't as prevalent, but they do still exist. 68 00:05:24,990 --> 00:05:26,110 We'll talk about that in a minute. 69 00:05:26,510 --> 00:05:28,790 Census spoofing is a really big thing. 70 00:05:28,790 --> 00:05:32,650 And disrupting and stopping the process, obviously the aim of what we want to do when we run a pen test. 71 00:05:33,070 --> 00:05:35,610 Tampering with SCADA and HMIs, and the list goes on. 72 00:05:36,030 --> 00:05:38,970 But really the problem is that these things aren't always baking cakes. 73 00:05:38,970 --> 00:05:43,290 They can create harsh chemical reactions, reach super high temperatures, get to immensely high pressures. 74 00:05:43,290 --> 00:05:48,230 They've got mechanical components, software components, physical attacks that can destroy operations in seconds. 75 00:05:48,370 --> 00:05:51,670 Like I said, surprisingly it's not a recipe for granny's apple pie, it's a recipe for disaster. 76 00:05:52,450 --> 00:05:56,110 So when we have a look at the impacts, let's take a look at what happens when these things go wrong. 77 00:05:56,710 --> 00:05:58,190 This is a Russian power station. 78 00:05:58,190 --> 00:06:00,810 It's probably one of the most famous ICS failures. 79 00:06:00,810 --> 00:06:07,710 This basically had a turbine, it was a 1,000 ton turbine that ramped up to such power in milliseconds, it killed 75 people. 80 00:06:07,830 --> 00:06:11,870 And if you look on the bottom left picture, you can probably see a guy standing on a wooden bridge. 81 00:06:11,950 --> 00:06:13,570 So that shows the scale of this. 82 00:06:13,930 --> 00:06:19,310 That basically made Russia almost launch a counter strike against the US because they thought it was a cyber attack. 83 00:06:19,430 --> 00:06:21,310 It wasn't at all, it was a cyber failure. 84 00:06:21,370 --> 00:06:37,090 It was a $2 sensor that had fallen off the side of a dam that had basically overfilled the reservoir, which was a big, On the left we've got a vehicle manufacturing plant, in the middle we've got a commercial boiler, and on the right we've got an expansion vessel which we've successfully blown up. 85 00:06:37,330 --> 00:06:41,330 Now, when we have a look on the left, let's make no mistake about it, that is an automated killing machine. 86 00:06:41,450 --> 00:06:45,970 If you walked in there, three-day safety interlocks, it would kill you, without a single shadow of a doubt. 87 00:06:46,510 --> 00:06:48,470 So what is it that actually stops it killing you? 88 00:06:49,150 --> 00:06:50,470 Well, safety devices. 89 00:06:50,790 --> 00:06:52,890 The things we rely on to keep us alive will always fail. 90 00:06:52,890 --> 00:06:59,110 And on the left we've got a thermostat, on the right we've got a temperature sensor, so on the far right we've got a pressure relief valve. 91 00:06:59,110 --> 00:07:00,650 Now, these will always fail. 92 00:07:00,650 --> 00:07:03,230 These are interchangeable parts, so we know they're going to fail at some point. 93 00:07:03,230 --> 00:07:07,550 In fact, when they do fail, like this, you've now got a bomb within your building. 94 00:07:07,550 --> 00:07:13,950 Because if that pressure ramps up for overheating or for anything like that, and the pressure relief valve does not go off, that's what will happen. 95 00:07:13,950 --> 00:07:16,170 And that's exactly how we blew that expansion vessel up. 96 00:07:16,570 --> 00:07:22,190 And when we have a look at safety interlocks and the things that we rely on to keep us alive, this is an ABB controller. 97 00:07:22,190 --> 00:07:24,210 You can see here we've got a door interlock. 98 00:07:26,590 --> 00:07:29,490 This is the controller for that robotic arm and for that interlock. 99 00:07:29,610 --> 00:07:31,010 All you need is a screwdriver. 100 00:07:31,010 --> 00:07:32,890 In fact, we don't even have the keys for that. 101 00:07:33,050 --> 00:07:36,030 So we just use a screwdriver to get into it ordinarily. 102 00:07:36,310 --> 00:07:37,570 So it's a big issue. 103 00:07:38,370 --> 00:07:44,930 Now, what we know about ICS is that over £30 billion, about $50 billion has been lost in ICS failure, ransom or cyber attacks. 104 00:07:45,090 --> 00:07:49,210 There's been 70-plus incidents with severe environmental damage, 1,000-plus deaths reportedly. 105 00:07:49,730 --> 00:07:56,630 An environmental disaster at Deepwater Horizon was massive, 68,000-plus square miles of ocean ruined. 106 00:07:56,630 --> 00:07:58,050 It's a big, big issue. 107 00:07:58,210 --> 00:08:02,250 When we have a look at what most of them run, most of them run Windows. 108 00:08:02,270 --> 00:08:05,390 And I know what you're thinking, but believe it or not, Windows does have bugs in it. 109 00:08:05,390 --> 00:08:06,650 So it's a big issue. 110 00:08:07,010 --> 00:08:10,010 And when we look at these systems, it does get worse. 111 00:08:10,430 --> 00:08:12,210 Most run Windows 7 still. 112 00:08:12,570 --> 00:08:14,350 Some even run Windows 98. 113 00:08:14,810 --> 00:08:16,350 So it's a big, big problem. 114 00:08:16,730 --> 00:08:21,510 So when we carry out impact-based pen testing ICS, what do we actually do? 115 00:08:21,850 --> 00:08:23,670 Well, the default rules do still apply. 116 00:08:23,670 --> 00:08:26,870 If you take a USB killer into these environments, clearly you're going to deck everything. 117 00:08:27,130 --> 00:08:29,430 We still use standard tools, et cetera. 118 00:08:29,630 --> 00:08:31,670 But you're going to find things on showdown. 119 00:08:31,730 --> 00:08:33,570 You're going to find web admin panels. 120 00:08:33,630 --> 00:08:35,530 You're going to find misconfigurations. 121 00:08:35,710 --> 00:08:37,510 You're going to be able to upgrade firmware. 122 00:08:37,790 --> 00:08:39,710 You're going to find default credentials. 123 00:08:40,410 --> 00:08:42,310 Now this is where things get a bit different. 124 00:08:42,670 --> 00:08:48,470 Now, we talk about the levels, and the Purger ICS model is probably considered the best thing for the levels of these devices. 125 00:08:48,590 --> 00:08:50,910 But levels seem to differ depending on where you look. 126 00:08:50,930 --> 00:08:54,870 In fact, here I've got three contradicting images of ICS levels. 127 00:08:55,250 --> 00:08:59,690 So for the purpose of this talk, and this is the issue, like, I think, like, how are we going to secure this stuff? 128 00:08:59,690 --> 00:09:00,670 We can't agree on the levels. 129 00:09:00,670 --> 00:09:03,650 But for the purpose of this talk, like, level three we see as SCADA. 130 00:09:03,650 --> 00:09:06,110 Level two we see as HMIs, PLCs, and controllers. 131 00:09:06,310 --> 00:09:07,770 Level one we see as sensors. 132 00:09:07,770 --> 00:09:10,910 And level zero we see as the fabric of buildings and the process. 133 00:09:10,910 --> 00:09:12,390 And we're going to talk about why that is. 134 00:09:12,730 --> 00:09:16,390 But when we talk about PLCs, we're talking about as programmable logic controller. 135 00:09:16,390 --> 00:09:17,830 I'm sure most of you know this anyway. 136 00:09:18,150 --> 00:09:19,610 But it's got multiple network types. 137 00:09:19,610 --> 00:09:22,510 We're not going to go too much into this, but we've got one of these around the corner. 138 00:09:22,510 --> 00:09:25,950 So if you want to see these and how we attack them, we're literally just out here. 139 00:09:26,110 --> 00:09:27,590 So we've got this exact one. 140 00:09:27,590 --> 00:09:28,630 We're happy to show you it. 141 00:09:28,930 --> 00:09:31,770 We're also talking about BMS systems, so building management systems. 142 00:09:31,770 --> 00:09:36,610 Now this is where I first started hacking these types of systems as a commercial gas engineer. 143 00:09:36,610 --> 00:09:40,410 These basically controlled all the set points and the building management throughout the building. 144 00:09:40,770 --> 00:09:42,830 And quite often these sit in these panels. 145 00:09:42,830 --> 00:09:46,390 So this is a 415 volt panel on the right-hand side. 146 00:09:46,390 --> 00:09:48,690 You need to be qualified to open those in the UK. 147 00:09:49,170 --> 00:09:51,430 Here we can actually see where that pressurization unit's had a leap. 148 00:09:51,430 --> 00:09:52,350 That's a different issue. 149 00:09:52,710 --> 00:09:54,730 But what do we get if we open these up? 150 00:09:55,210 --> 00:09:57,770 What we get is a router and a power socket. 151 00:09:58,630 --> 00:10:00,710 So straight away for us, that's a good spot. 152 00:10:01,350 --> 00:10:05,150 Now what's an ethical hacker going to do when they find a router in a locked cupboard with persistent power? 153 00:10:05,790 --> 00:10:07,470 Of course you're going to get your cat to hack it. 154 00:10:08,250 --> 00:10:10,070 So what does that hack look like? 155 00:10:10,410 --> 00:10:16,710 So what we did was, obviously I wanted to make a device that I could put into this cupboard and it isn't going to get found or isn't really going to alert people straight away. 156 00:10:16,710 --> 00:10:18,270 So I made this, it's called a hack plug. 157 00:10:18,410 --> 00:10:30,630 And basically it's got multiple interfaces so it can connect to an ethernet, it can work through the power line for extra tracing data, it can connect to wifi, it also works on 3G and 4G and it's got local protocols as well like B2 flow energy so you can connect to it locally. 158 00:10:31,070 --> 00:10:32,970 Now to drill into this quickly with the components. 159 00:10:32,970 --> 00:10:37,910 Components, it's a surge protector lead, it's got a D-shelled laptop power supply which gives us 4 amps. 160 00:10:38,270 --> 00:10:41,410 It's got pi zero, that's running Cali for, for pi two. 161 00:10:41,490 --> 00:10:43,630 It's got wifi module, ethernet connector. 162 00:10:44,130 --> 00:10:45,470 Yeah, it's got all that in it. 163 00:10:45,470 --> 00:10:47,230 So, we'll give you the spec it's off if you want. 164 00:10:47,410 --> 00:10:50,610 So, now we're talking about default rules do not apply. 165 00:10:50,730 --> 00:10:52,850 So, ICS safe network enumeration. 166 00:10:52,870 --> 00:10:55,630 So here's an example of how you'd enumerate an ICS network safely. 167 00:10:55,630 --> 00:10:58,810 Because even just enumerating a network can flood it and deny the service on it. 168 00:10:59,110 --> 00:11:02,390 So once we've done that, we want to start looking at safe test streaks. 169 00:11:02,390 --> 00:11:06,170 So we're not taking down an actual process, although we did and we'll talk about that in a minute. 170 00:11:06,170 --> 00:11:08,550 But a lot of what we froze are these test streaks. 171 00:11:08,550 --> 00:11:10,510 They work in the exact same way as a process. 172 00:11:10,550 --> 00:11:12,350 Um, so they're really, really good bits of kit. 173 00:11:12,850 --> 00:11:18,170 But what are we actually talking about when we say SCADA, ICS, plant, PLCs, RTUs? 174 00:11:18,310 --> 00:11:21,890 Well, this is what we consider plant equipment, so heating, cooling, distribution. 175 00:11:21,890 --> 00:11:26,950 Here we've got gas meters, thermostatic controller, uh, fan core unit and some commercial boilers. 176 00:11:27,270 --> 00:11:31,930 Here we've got shop floor equipment, so things that you'd find throughout a process on a shop floor. 177 00:11:32,270 --> 00:11:36,990 We've got HMIs, human machine interfaces, quite often run Windows CE, Windows Embedded. 178 00:11:37,430 --> 00:11:38,830 Here we've got remote terminal units. 179 00:11:38,830 --> 00:11:42,130 I think over here they're referred to as remote, uh, telemetry units. 180 00:11:42,350 --> 00:11:44,230 Um, we've also got field terminal units. 181 00:11:44,270 --> 00:11:46,110 But more importantly, we've got the sensors. 182 00:11:46,150 --> 00:11:47,890 Now these are the tentacles of a control system. 183 00:11:47,890 --> 00:11:49,750 They're the eyes and ears of a control system. 184 00:11:49,850 --> 00:11:54,030 Um, they report on information such as temperature, pressure, flow, humidity, orientation. 185 00:11:54,070 --> 00:11:56,050 They report that back to the PLC. 186 00:11:56,450 --> 00:11:59,330 Now these are types of sensors that you can have throughout these environments. 187 00:11:59,330 --> 00:12:03,050 So you can have a whole plethora of, um, of sensors available to you. 188 00:12:03,450 --> 00:12:06,830 But when we start looking at, uh, sensors, we move into safety devices. 189 00:12:07,010 --> 00:12:10,070 Um, when we look at safety interlocks, they're made to keep us alive. 190 00:12:10,070 --> 00:12:11,630 They stop machines in an emergency. 191 00:12:11,890 --> 00:12:17,190 Obviously throughout processes we have emergency stop buttons, but that's an electrical circuit reporting to an electronic device. 192 00:12:17,210 --> 00:12:20,670 In fact, we know from Stuxnet that the emergency stop buttons weren't working. 193 00:12:20,670 --> 00:12:22,410 And there's a number of ways of doing that. 194 00:12:22,410 --> 00:12:26,290 We've got either heat sensors, expansion vessels, pressure relief valves like we discussed. 195 00:12:26,370 --> 00:12:29,630 I'm not gonna list everything here, but you get the idea of, of what we're talking about. 196 00:12:30,030 --> 00:12:35,150 Now, when we have a look at attacks, and obviously this is what everyone really wants to see. 197 00:12:36,170 --> 00:12:37,410 It's safe, right? 198 00:12:38,450 --> 00:12:40,330 Well, actually not even safe's a safe. 199 00:12:41,150 --> 00:12:43,730 So this is research I've done over like the past five or six years. 200 00:12:43,730 --> 00:12:44,710 It's pretty old now. 201 00:12:45,070 --> 00:12:46,710 But you can see it just proves it's locked. 202 00:12:51,690 --> 00:12:53,210 That's all it takes to get into it. 203 00:12:53,250 --> 00:12:58,850 So I put this out, and I've been in the hacking community for quite a while, and, um, everyone was like, yeah, you know, that's great, but it's a crappy safe, whatever. 204 00:12:59,210 --> 00:13:01,470 So I was like, all right, the challenge accepted. 205 00:13:02,250 --> 00:13:04,310 So this is Costco's display safe. 206 00:13:04,310 --> 00:13:05,990 So this is a century safe. 207 00:13:06,070 --> 00:13:07,090 It's a medium range safe. 208 00:13:07,090 --> 00:13:07,910 It's not super cheap. 209 00:13:07,910 --> 00:13:08,970 It's not super expensive. 210 00:13:11,050 --> 00:13:13,230 And it's basically just says we're in Costco. 211 00:13:18,330 --> 00:13:25,530 So it's just a rare earth magnet, if you can't hear it, and a sock. 212 00:13:34,820 --> 00:13:35,820 Simple as that. 213 00:13:36,300 --> 00:13:38,380 So obviously, responsible disclosure. 214 00:13:38,420 --> 00:13:41,120 We told Century about this, and we said, look, we found the floor in your safe. 215 00:13:41,120 --> 00:13:43,480 And they said, yeah, yeah, that's great, but we're not really interested. 216 00:13:43,480 --> 00:13:44,880 We've defended it on the next one. 217 00:13:45,080 --> 00:13:46,620 And they're releasing a new version. 218 00:13:46,780 --> 00:13:47,620 So it's all right. 219 00:13:47,620 --> 00:13:48,400 Fair enough. 220 00:13:48,660 --> 00:13:51,020 So, uh, this is their current version. 221 00:13:51,080 --> 00:13:52,500 So this is their new version. 222 00:13:52,500 --> 00:13:54,060 This is the one that you can buy now. 223 00:14:13,460 --> 00:14:21,480 All you actually need to do is take the tape forward, and put it back. 224 00:14:23,960 --> 00:14:26,260 And this is their most recent one. 225 00:14:26,300 --> 00:14:32,220 So what we're saying is that even safe products aren't necessarily safe and people will more than happily sell you stuff, which is insufficient. 226 00:14:32,820 --> 00:14:36,840 Now, when we look at the way that this actually works, this is what's inside them. 227 00:14:36,840 --> 00:14:38,360 It's an electromagnetic solenoid valve. 228 00:14:38,360 --> 00:14:40,660 I can list off loads of attacks on these. 229 00:14:40,860 --> 00:14:43,200 Um, but this video just shows a bit about how it works. 230 00:14:49,080 --> 00:14:53,440 So basically when you put the pin in, it doesn't interfere with the lock at all. 231 00:14:55,280 --> 00:15:01,080 All it does is closes the circuit, which makes this go like that. 232 00:15:01,560 --> 00:15:02,220 That's it. 233 00:15:02,220 --> 00:15:03,880 That clears the way for you to do it. 234 00:15:04,040 --> 00:15:08,520 So obviously the way to do it is you bang it, which just bounces this up and down. 235 00:15:08,520 --> 00:15:09,940 So when you bang it, that's what you're doing. 236 00:15:09,940 --> 00:15:11,860 Short circuit here. 237 00:15:12,020 --> 00:15:13,560 Short circuit here. 238 00:15:14,320 --> 00:15:19,540 Or just use the magnet, and the magnet just emulates this electromagnet. 239 00:15:20,000 --> 00:15:21,960 And again, in turn pulls it down. 240 00:15:22,580 --> 00:15:23,460 That's it. 241 00:15:23,460 --> 00:15:25,380 This one keeps you safe and safe. 242 00:15:25,380 --> 00:15:26,280 Nothing complicated. 243 00:15:26,280 --> 00:15:36,400 So in fact, when we started looking at these, I went down the security aisle in Homebase, which is like Home Depot over here, and we hacked every single thing in this picture, but they're still happy to sell them. 244 00:15:36,660 --> 00:15:37,860 So it's a big problem. 245 00:15:37,860 --> 00:15:40,520 But how do we know how to tackle these? 246 00:15:40,980 --> 00:15:44,600 Well, in fact, they're all gas valves that we find throughout industrial environments. 247 00:15:44,600 --> 00:15:46,480 They're any smart valve, pretty much. 248 00:15:46,860 --> 00:15:54,180 And when we look at examples of where these are, on the top left, you've got a gas valve, which is probably what you'd find in your domestic boiler at home. 249 00:15:54,920 --> 00:15:57,960 That's just got two electromagnetic solenoids on it. 250 00:15:57,960 --> 00:16:00,000 It's just got one for the pilot, one for the main burner. 251 00:16:00,500 --> 00:16:03,260 And then here we can see more commercial industrial ones. 252 00:16:03,260 --> 00:16:07,820 Now, these are all safety interlocked into things like fire alarms, into emergency stop buttons. 253 00:16:07,820 --> 00:16:11,360 So if a fire alarm is triggered, then it will shut the gas supply off into a building. 254 00:16:11,780 --> 00:16:13,960 So if you can mess with that, you can mess with these. 255 00:16:14,040 --> 00:16:15,280 So that's a big issue. 256 00:16:15,780 --> 00:16:20,320 Now, when we have a look at things like sensors, this is in ABB's reception. 257 00:16:20,400 --> 00:16:25,420 And basically this says, when you can measure what you're speaking about and express it in numbers, you know something about it. 258 00:16:25,420 --> 00:16:29,100 When you cannot measure it, your knowledge is meager and unsatisfactory. 259 00:16:29,200 --> 00:16:30,720 And it's completely true. 260 00:16:30,720 --> 00:16:36,000 Sensors are probably one of the most important things for an industrial process or a commercial process or whatever you're doing. 261 00:16:36,300 --> 00:16:40,360 And sensors really are the keys to the kingdom, I think anyway, and we'll talk about why. 262 00:16:40,540 --> 00:16:44,100 Now, like we said, the sensors are the tentacles of the control system. 263 00:16:44,100 --> 00:16:45,720 They're very easily spoofed. 264 00:16:45,720 --> 00:16:48,200 But the network accepts that data as fact. 265 00:16:48,280 --> 00:16:52,360 So if that data has been pushed up from a sensor, the network will always accept it. 266 00:16:52,360 --> 00:16:53,640 The PLC will always accept it. 267 00:16:53,640 --> 00:16:56,660 It's got no way of checking if it's correct or not. 268 00:16:56,660 --> 00:17:03,200 They work on a 4 to 20 milliamp circuit, some of them, which measures things like resistance, current, or digital output, so with a UID, etc. 269 00:17:03,620 --> 00:17:04,960 But they're very easy to trick. 270 00:17:04,960 --> 00:17:09,000 It's very easy to trick the system into doing something, or more importantly, trick people into doing something. 271 00:17:09,160 --> 00:17:14,880 Now, if you can spoof these sensors and you make it look like heat detectors are going off everywhere, that looks to an operator like there's a fire. 272 00:17:14,920 --> 00:17:16,760 The first thing that he's going to do is shut everything down. 273 00:17:16,760 --> 00:17:19,240 In reality, there's nothing going wrong with that process at all. 274 00:17:19,340 --> 00:17:21,140 So spoofing the sensors is a big thing. 275 00:17:21,220 --> 00:17:23,620 These are really easy to intercept, manipulate, and forward on. 276 00:17:23,800 --> 00:17:25,560 A bunch of different ways that they work. 277 00:17:25,560 --> 00:17:29,460 But like we said, they look at things like temperature, pressure, fill levels, etc. 278 00:17:30,060 --> 00:17:32,940 Then we start to have a look at ICS network attacks. 279 00:17:33,440 --> 00:17:35,240 Clearly, denial-of-service attacks still work. 280 00:17:35,240 --> 00:17:37,580 With that, you can stop control, you can stop visibility. 281 00:17:37,660 --> 00:17:41,420 So if you can carry out a denial-of-service attack, you can stop people controlling those PLCs. 282 00:17:41,700 --> 00:17:48,960 Obviously, we look at things like fuzzing protocols, but most of the switches that we find on these systems are unmanaged, which is a big, big problem, obviously. 283 00:17:49,220 --> 00:17:51,620 Now, with that, if you can connect, you can control. 284 00:17:51,620 --> 00:17:59,940 So you can attack any levels connected to the network, whether that's a supervisory thing or a corporate network, you can attack all of them. 285 00:18:00,000 --> 00:18:06,740 And really, you don't need Metasploit or 1710 Eternal Blue when you have TIA Portal, which is Siemens' proprietary software. 286 00:18:06,780 --> 00:18:13,300 If you can get onto a network, you literally click enumerate all the PLCs around you, and it will give you a list of all of them, which is a massive, massive issue. 287 00:18:13,320 --> 00:18:14,900 So local access is a big thing. 288 00:18:15,400 --> 00:18:19,940 Now, when we have a look at the limitations of the network, this is a standard denial-of-service attack. 289 00:18:19,940 --> 00:18:24,300 So to anybody that's really technical and uses LOIC or HOIC, you don't need either of them. 290 00:18:24,300 --> 00:18:26,880 Literally, all you need is Hyperping, that's it. 291 00:18:27,280 --> 00:18:35,980 Here it just shows a basic denial-of-service attack, but on that port and the right IP address, you'll stop a supervisor communicating with that network, basically. 292 00:18:36,480 --> 00:18:38,800 Really, really simple attack, really simple. 293 00:18:39,320 --> 00:18:44,520 Now, when we look at hacking human segregation, the things that we use to keep us alive, these are standard interlocks. 294 00:18:44,520 --> 00:18:48,120 So here we've got a Schneider one on the left, and that works with a twin-pole magnetic switch. 295 00:18:48,120 --> 00:18:50,320 On the right, we've got a light barrier. 296 00:18:50,500 --> 00:18:53,220 But engineers ordinarily use these to cut the system off anyway. 297 00:18:53,220 --> 00:18:57,740 So rather than walking right back to a panel, they just stick their hand through it, and that will cut the system off. 298 00:18:57,740 --> 00:18:59,180 They're expecting it to anyway. 299 00:18:59,580 --> 00:19:00,860 So that's a big problem. 300 00:19:00,860 --> 00:19:04,600 But if we have a look at what we need to hack these, of course we use computers. 301 00:19:04,600 --> 00:19:07,560 But really, you need things like magnets, screwdrivers, and mirrors. 302 00:19:07,840 --> 00:19:12,820 If you've got these three things, you can start causing havoc within industrial environments. 303 00:19:13,200 --> 00:19:21,040 So, if we have a look at PLCs and stopping the process, this is another quick video that we made of a demonstration. 304 00:19:21,280 --> 00:19:23,760 So here, the test rig is just running the process. 305 00:19:24,060 --> 00:19:28,160 It picks this up, verifies there's a hole in it, transfers it over. 306 00:19:31,120 --> 00:19:33,240 And here we can see from our attack machine. 307 00:19:36,120 --> 00:19:38,500 Sticking in the IP, setting the port number. 308 00:19:39,820 --> 00:19:42,600 And there's a couple of frameworks out there that you can get for this. 309 00:19:46,030 --> 00:19:49,350 Set port to 102, which is Siemens control port. 310 00:19:52,350 --> 00:19:53,450 It counts down here. 311 00:19:53,450 --> 00:19:55,950 3, 2, 1. 312 00:19:57,230 --> 00:20:00,550 And that would work as well on any huge industrial process. 313 00:20:00,550 --> 00:20:02,290 I mean, don't be fooled, because this is a small rig. 314 00:20:02,290 --> 00:20:05,690 Because it's working the exact same way as a proper industrial process would. 315 00:20:06,070 --> 00:20:09,210 So, when we start having a look at hacking these safety devices. 316 00:20:09,270 --> 00:20:10,470 These are easy to bypass. 317 00:20:10,470 --> 00:20:12,930 A lot of them are normally open or normally closed devices. 318 00:20:12,930 --> 00:20:15,090 So they're very easy to satisfy or not satisfy. 319 00:20:15,090 --> 00:20:18,110 We can very, very easily cause over-pressurization. 320 00:20:18,570 --> 00:20:20,790 That turns your infrastructure into a bomb, like we said. 321 00:20:20,790 --> 00:20:22,390 And we can see the effects of this here. 322 00:20:22,390 --> 00:20:26,090 Whether you want to blow heat exchanges, you want to blow expansion vessels, you want to blow pulse rebuildings. 323 00:20:26,090 --> 00:20:27,630 That's a good way of doing it. 324 00:20:28,170 --> 00:20:30,390 Obviously, you can overheat processes and equipment. 325 00:20:30,410 --> 00:20:32,030 You can blow expansion vessels, like we said. 326 00:20:32,030 --> 00:20:33,190 That's often the first thing to go. 327 00:20:33,190 --> 00:20:36,630 So, wherever you've got heat in a system, obviously that creates expansion. 328 00:20:36,810 --> 00:20:39,470 To absorb that expansion, you need an expansion vessel. 329 00:20:39,590 --> 00:20:41,150 If you can cap that, or you can take it out. 330 00:20:41,150 --> 00:20:44,170 Or even just overheat or over-pressurize it with a defective PRV. 331 00:20:44,170 --> 00:20:45,550 That's exactly what's going to happen. 332 00:20:46,010 --> 00:20:47,990 With that, you can destroy property and cause huge damage. 333 00:20:47,990 --> 00:20:49,310 Of course, you can kill people. 334 00:20:49,450 --> 00:20:51,010 It's one of the biggest effects of this. 335 00:20:51,030 --> 00:20:54,370 If you understand the process or the cycle of setup, then your adversary is in trouble. 336 00:20:54,450 --> 00:20:55,730 And we call that the modern spanner. 337 00:20:55,730 --> 00:20:57,870 Because people say about putting a spanner in the works. 338 00:20:57,890 --> 00:20:59,690 Well, you're not going to chuck a spanner in an industrial process. 339 00:20:59,690 --> 00:21:02,370 But the right thing in the right place will always work. 340 00:21:02,370 --> 00:21:05,390 And really, it's just knowing that system and what that means. 341 00:21:06,310 --> 00:21:08,230 Now, of course, in SCADA, things get ransomed. 342 00:21:08,230 --> 00:21:10,630 It's a case study of a company in South Brazil. 343 00:21:10,930 --> 00:21:12,590 They got done with Cryptolocker. 344 00:21:12,590 --> 00:21:14,450 In fact, I think that was a big Taiwanese manufacturer. 345 00:21:14,450 --> 00:21:17,690 The biggest manufacturer in Taiwan that was down for two days. 346 00:21:17,690 --> 00:21:20,890 And when you look at the cost of what that means, it's a big, big issue. 347 00:21:21,590 --> 00:21:23,370 So now, let's get to some of our research. 348 00:21:23,590 --> 00:21:25,830 One of our clients, extremely well-known company. 349 00:21:26,370 --> 00:21:29,170 We were going to say what sector they were in, but they weren't very happy about it. 350 00:21:29,170 --> 00:21:31,490 But basically, they gave us access to multiple lines. 351 00:21:31,490 --> 00:21:33,370 But we were provided with one to attack it. 352 00:21:33,370 --> 00:21:36,010 So they run four lines in their facility. 353 00:21:36,290 --> 00:21:39,770 Each one of those lines makes £10,000 of production a minute. 354 00:21:40,010 --> 00:21:41,330 It's a super, super high value. 355 00:21:41,330 --> 00:21:42,310 But that's not uncommon. 356 00:21:42,410 --> 00:21:43,950 That's not uncommon at all. 357 00:21:44,450 --> 00:21:46,290 And that's for each production line. 358 00:21:46,450 --> 00:21:48,890 We didn't want to attack level four and five, it was out of scope. 359 00:21:48,890 --> 00:21:50,270 So we didn't want to attack that at all. 360 00:21:50,270 --> 00:21:52,770 And we did not want to leave a trace, more importantly. 361 00:21:53,130 --> 00:21:55,970 So, getting into how we lost our client this money. 362 00:21:56,070 --> 00:21:57,090 How did it actually work? 363 00:21:57,090 --> 00:21:58,750 Step one, we wanted physical access. 364 00:21:58,750 --> 00:22:00,530 Like we said, we want impact-based stuff. 365 00:22:00,550 --> 00:22:01,930 And we're going to talk about physical access. 366 00:22:01,930 --> 00:22:04,790 That doesn't mean that you have to walk in and do stuff. 367 00:22:04,790 --> 00:22:06,130 But we wanted physical access. 368 00:22:07,090 --> 00:22:09,130 Next, we wanted to weaponize an Arduino. 369 00:22:09,130 --> 00:22:11,130 So we wanted that to enumerate the network. 370 00:22:11,130 --> 00:22:12,410 Again, unmanaged switches. 371 00:22:12,410 --> 00:22:14,250 So really, really easy to get onto the network. 372 00:22:14,310 --> 00:22:16,170 Enumerate the network and tell us what it is. 373 00:22:16,230 --> 00:22:19,490 And when we say about physical access, it could be something like this. 374 00:22:19,490 --> 00:22:20,090 Again. 375 00:22:20,290 --> 00:22:22,270 So it could just be sticking an extension lead in. 376 00:22:22,270 --> 00:22:24,550 Which is really, really difficult for people to identify. 377 00:22:24,870 --> 00:22:27,550 And then of course, step four was the actual attack. 378 00:22:27,910 --> 00:22:29,510 Now this is not our attack code. 379 00:22:29,510 --> 00:22:30,610 This is from a framework. 380 00:22:30,610 --> 00:22:32,230 But you can see that the attack... 381 00:22:32,230 --> 00:22:34,010 I actually struggle to call it an attack. 382 00:22:34,010 --> 00:22:37,070 Because all we've actually done is just sent these PLC stop commands. 383 00:22:37,070 --> 00:22:37,950 That's it. 384 00:22:37,950 --> 00:22:40,090 And we just keep repeating those stop commands. 385 00:22:40,090 --> 00:22:42,090 It's really, really difficult to stop. 386 00:22:42,130 --> 00:22:49,070 So as much as I want to say it's some super technical work chain, like buffer overflow or shellcode exploit, it really isn't. 387 00:22:49,070 --> 00:22:50,630 All it is is just stop commands. 388 00:22:50,630 --> 00:22:51,890 And you can see those here. 389 00:22:52,790 --> 00:22:54,330 Really, really simple stuff. 390 00:22:54,470 --> 00:22:56,990 So within five seconds, the attack's complete. 391 00:22:57,050 --> 00:23:01,670 We took the former head of the Metropolitan Police e-crime unit with us to investigate. 392 00:23:01,770 --> 00:23:05,710 And he said that after his investigation, there was no way to easily identify the attack. 393 00:23:05,710 --> 00:23:07,050 And definitely not enough artifacts. 394 00:23:07,050 --> 00:23:08,930 For attribution. 395 00:23:09,050 --> 00:23:10,190 So we really got away with it. 396 00:23:10,190 --> 00:23:10,810 Really. 397 00:23:10,870 --> 00:23:11,630 That's the truth of it. 398 00:23:11,630 --> 00:23:14,650 And even when we did get physical access, there was blind spots everywhere. 399 00:23:14,650 --> 00:23:15,990 No physical controls. 400 00:23:15,990 --> 00:23:17,670 It was a massive, massive problem for them. 401 00:23:18,150 --> 00:23:20,250 So the production line was down for two hours. 402 00:23:20,250 --> 00:23:21,810 All safety checks were carried out. 403 00:23:22,130 --> 00:23:24,790 Again, I would be very naive to think that it's just a simple reset. 404 00:23:24,790 --> 00:23:25,490 It's not. 405 00:23:25,510 --> 00:23:29,190 Any company that's responsible is going to want to know why their process has stopped. 406 00:23:29,190 --> 00:23:30,570 It's somebody trapped in a machine. 407 00:23:30,570 --> 00:23:34,950 And when we look at this client, for example, their site was over 40 acres. 408 00:23:35,030 --> 00:23:36,950 So it's a huge, huge plant. 409 00:23:37,510 --> 00:23:38,890 They're not just going to click reset. 410 00:23:38,890 --> 00:23:40,470 What they're going to do is an SCBO. 411 00:23:40,470 --> 00:23:42,530 So they're going to do a status check before operation. 412 00:23:42,550 --> 00:23:43,950 Before they reset it. 413 00:23:43,950 --> 00:23:45,350 So it's down for two hours. 414 00:23:45,350 --> 00:23:46,550 It was only one line. 415 00:23:46,550 --> 00:23:47,510 That's £10,000. 416 00:23:47,510 --> 00:23:48,690 That's 120 minutes. 417 00:23:48,690 --> 00:23:51,650 £1.2 million that they lost in that amount of time. 418 00:23:51,650 --> 00:23:54,590 If it had been on all four lines, it would have been £4.8 million. 419 00:23:54,770 --> 00:24:00,970 So if we look at that compared to the Taiwanese attack that we've just seen, which was two days, they would have lost millions. 420 00:24:00,970 --> 00:24:02,710 They would have lost tens, even hundreds of millions. 421 00:24:02,710 --> 00:24:03,730 They would have lost on that. 422 00:24:04,590 --> 00:24:08,290 So all of these things are critical to the operation of modern society. 423 00:24:08,290 --> 00:24:10,430 And now we're seeing a lot of industrial IOT. 424 00:24:11,130 --> 00:24:16,510 So when we look at some of the hardware attacks, obviously we attack the sensors, obviously we want to bypass safety interlocks. 425 00:24:16,510 --> 00:24:19,430 Even a power surge or a flood would be a legit vector. 426 00:24:19,710 --> 00:24:26,050 But really, we look at things like chip decapping, IOT, reverse engineering, UR attacks, and everyone thinks that's some crazy voodoo hacker shit. 427 00:24:26,050 --> 00:24:26,930 It's not at all. 428 00:24:26,930 --> 00:24:29,670 What it actually is, is me. 429 00:24:29,670 --> 00:24:33,230 I was actually at my mum's house on a dining room table when I was at a family event. 430 00:24:33,890 --> 00:24:40,870 Basically I've just stripped down a Philips Hue, I've banged some headers into it, and then I've used an Arduino to start carrying out a UR attack. 431 00:24:41,170 --> 00:24:44,350 Straight away we've got into the boot loader, we can set the security EMV. 432 00:24:44,550 --> 00:24:47,250 As soon as you do that, you drop into a root shell. 433 00:24:47,630 --> 00:24:48,690 Simple as that. 434 00:24:48,690 --> 00:24:51,670 And we're seeing a lot of this type of stuff in industrial IOT. 435 00:24:51,810 --> 00:24:53,010 It's a big, big issue. 436 00:24:53,890 --> 00:24:57,270 Again, when we look at current solutions, we didn't want to reinvent the wheel. 437 00:24:57,270 --> 00:25:00,910 We wanted to put really sensible things in place for our clients. 438 00:25:01,050 --> 00:25:02,770 So we started looking at secure RJ45. 439 00:25:02,770 --> 00:25:04,450 Now, unmanaged switches, big issue. 440 00:25:04,450 --> 00:25:05,710 Someone's going to plug into it. 441 00:25:05,710 --> 00:25:09,750 So we wanted to occupy those ports, and we wanted to do that with secure RJ45. 442 00:25:10,030 --> 00:25:14,690 So we went to this company, and we said, look, we're a team of hackers and security engineers. 443 00:25:15,290 --> 00:25:19,050 In reality, are we going to be able to stick a screwdriver into your product and get it out? 444 00:25:19,050 --> 00:25:20,430 And they said, no, no, no way. 445 00:25:20,430 --> 00:25:21,130 Of course you can't. 446 00:25:21,130 --> 00:25:22,630 If you did, you'll just damage it. 447 00:25:22,830 --> 00:25:24,310 So they sent us a sample kit. 448 00:25:24,310 --> 00:25:25,690 This is their sample kit. 449 00:25:25,690 --> 00:25:27,810 This is within three minutes of receiving it. 450 00:25:43,640 --> 00:25:45,560 So you can see it didn't take a screwdriver at all. 451 00:25:45,560 --> 00:25:46,700 It took two spoons. 452 00:25:47,180 --> 00:25:47,960 That was it. 453 00:25:48,280 --> 00:25:52,080 So what we're saying is there is no real secure options, despite the marketing. 454 00:25:52,080 --> 00:25:55,800 So despite what we see people marketing stuff as, we don't really consider them to be secure. 455 00:25:55,940 --> 00:25:57,520 There's no real tamper evidence or alerting. 456 00:25:57,520 --> 00:25:59,280 It just damages it, if it damages it at all. 457 00:25:59,280 --> 00:26:02,480 Like we said, you can get through these without damaging it at all. 458 00:26:02,480 --> 00:26:06,000 It's huge limitations on applications and usability of this type of kit. 459 00:26:06,940 --> 00:26:10,860 So in summary, hacking ICS is serious. 460 00:26:10,860 --> 00:26:14,240 Hacking stuff has severe consequences, obviously, because of what's involved in it. 461 00:26:14,240 --> 00:26:16,180 It's not a simple reset or recovery. 462 00:26:16,180 --> 00:26:18,420 It loses a shed load of money. 463 00:26:18,800 --> 00:26:21,800 And it can mess with things we all rely on to keep us safe and secure. 464 00:26:21,880 --> 00:26:25,060 Of course the biggest thing is it can directly kill people. 465 00:26:25,060 --> 00:26:27,140 And that has happened with a thousand plus deaths. 466 00:26:27,420 --> 00:26:30,480 But what I'd say is that people will often not PLCs, and so it's bad. 467 00:26:30,480 --> 00:26:31,940 PLCs are great bits of kit. 468 00:26:32,000 --> 00:26:35,200 Super, super reliable bits of kit that we all rely on every day. 469 00:26:35,400 --> 00:26:40,620 But they're clearly not as mature as computer systems, and we definitely haven't got that maturity and security of them. 470 00:26:41,060 --> 00:26:45,380 So really, that's why we give talks like this, and why we want more people to get involved, and hopefully help us secure them. 471 00:26:45,920 --> 00:26:47,260 And that is pretty much it for me. 472 00:26:47,260 --> 00:26:48,480 I'm open to any questions. 473 00:26:50,640 --> 00:26:51,240 Yeah? 474 00:26:51,240 --> 00:26:51,680 Yeah? 475 00:26:53,360 --> 00:26:53,680 Yeah 476 00:27:01,580 --> 00:27:01,900 . 477 00:27:03,380 --> 00:27:05,800 I think, to be honest, this hasn't been on people's radar. 478 00:27:05,800 --> 00:27:08,420 And I think security for obscurity has been a big thing for this. 479 00:27:08,420 --> 00:27:12,740 Now it's very difficult to get access to labs, and I've been saying a lot more of that now with things like the ICS village. 480 00:27:12,740 --> 00:27:18,160 I think it comes to the understanding of what people are doing, but also it comes to the reporting of it. 481 00:27:18,240 --> 00:27:23,040 Now under GDPR obviously people have to report if there's been some sort of data breach, but would they have to report a crypto attack? 482 00:27:23,040 --> 00:27:23,860 Maybe not. 483 00:27:24,420 --> 00:27:27,840 In the UK especially, you're not obliged to report anything to the police. 484 00:27:30,120 --> 00:27:30,640 Yeah. 485 00:27:31,400 --> 00:27:32,320 Hopefully, yeah. 486 00:27:33,860 --> 00:27:35,040 So it's a big issue. 487 00:27:35,040 --> 00:27:36,020 I mean, how much is it going on? 488 00:27:36,020 --> 00:27:38,060 We haven't really got too much visibility in it. 489 00:27:38,500 --> 00:27:40,520 But yeah, I'd say at the moment we've been very lucky. 490 00:27:40,560 --> 00:27:43,800 And I think when somebody finds a way to ransom PLCs it's going to be a big problem. 491 00:27:43,800 --> 00:27:48,520 Because there's so many of these on Shodan that literally you can get access to hundreds, thousands of them. 492 00:27:51,670 --> 00:27:52,030 Cool. 493 00:27:52,030 --> 00:27:52,890 Any other questions? 494 00:27:54,550 --> 00:27:55,050 Cool. 495 00:27:55,050 --> 00:27:57,410 Well yeah, if anyone's got any questions, as I've said, we're right on the corner. 496 00:27:57,970 --> 00:28:00,190 Just find me or my colleague Simon at the top of the chat. 497 00:28:00,950 --> 00:28:01,470 Cool.