1 00:00:00,000 --> 00:00:02,540 All right, everyone, thank you for coming to our talk. 2 00:00:02,940 --> 00:00:05,980 It's named Extending Zeke for ICS Defense. 3 00:00:06,720 --> 00:00:08,200 My name is Norman Lunt. 4 00:00:08,200 --> 00:00:11,080 As the slide shows you, I'm a security enthusiast. 5 00:00:11,440 --> 00:00:22,320 I love PCAPs, and I love the defense side of this game, where if I can find you anywhere, we'll get you out. 6 00:00:24,680 --> 00:00:30,800 Hey, I'm James Dickinson, and as the slide shows, I'm also a security enthusiast. 7 00:00:30,800 --> 00:00:37,260 And much like Norm, I enjoy PCAPs and packets that are placed inside of PCAPs. 8 00:00:40,700 --> 00:00:46,520 All right, so to start us off, we're going to talk about some fundamental definitions in case anybody doesn't know. 9 00:00:46,980 --> 00:00:52,460 I'm just going to refer to them by their acronym names and not by their full names as it suits me. 10 00:00:52,620 --> 00:00:55,360 So ICS stands for Industrial Control System. 11 00:00:55,860 --> 00:00:59,180 PLC is Programmable Logic Controller. 12 00:00:59,460 --> 00:01:01,900 HMI for Human Machine Interface. 13 00:01:02,040 --> 00:01:05,340 And NSM stands for Network Security Monitoring. 14 00:01:06,160 --> 00:01:08,800 All right, so who cares about ICS data, right? 15 00:01:09,500 --> 00:01:15,380 It seems in the NSM world, ICS is just an afterthought. 16 00:01:15,380 --> 00:01:24,160 Nobody cares, gives a good doggone about what's happening on Modbus or what's happening on DMP3 or what's happening with all your Siemens PLCs. 17 00:01:25,000 --> 00:01:37,540 So what happens, I downloaded the most recent version of Zeek, and I built it from source, and I discovered that three out of 72 out-of-the-box analyzers were for ICS. 18 00:01:38,120 --> 00:01:55,040 And I went online, I poked around, and the Survey of Security Tools for the Industrial Control System Environment said, the survey identified tools such as Bro, which is what Zeek used to be called, Snort and Yara, which are by design highly extensible. 19 00:01:55,180 --> 00:02:01,060 Enough so that with minor development, they could be used as ICS solutions for which there's no current tool set. 20 00:02:04,290 --> 00:02:12,090 So every year, more and more devices are exposed to attack. 21 00:02:12,770 --> 00:02:25,850 And the people who want ICS in their systems, a lot of times they don't care about security because they haven't been hacked or they haven't gotten to a point where they need security. 22 00:02:26,290 --> 00:02:31,230 And so they'll be advised and say, hey, you know what, if we expose this internet, we're probably going to get in trouble. 23 00:02:31,470 --> 00:02:36,210 And they're like, I don't care, it's not affecting my bottom dollar yet, just push it, just push it, just push it. 24 00:02:36,530 --> 00:02:48,970 And so from Security Week.com, this is a report from 2017, they used Shodan, Synthesis and Google search engines and they identified over 170,000 ICS components accessible from the web. 25 00:02:49,850 --> 00:02:52,670 And it was a 10% growth from 2016 to 2017. 26 00:02:52,710 --> 00:02:55,230 I don't know what it is currently, but I don't think it got less. 27 00:02:55,230 --> 00:03:12,590 I don't think they're like, you know what, we better not put more ICS stuff out there because, you know , so why this is really relevant is programmable logic controllers or ICSs in general aren't fault tolerant. 28 00:03:13,030 --> 00:03:18,870 Like if at any point you send your data out of order or a malformed packet or something just doesn't hit right, it just crashes. 29 00:03:18,910 --> 00:03:21,470 And sometimes it crashes in a state that's unrecoverable. 30 00:03:22,310 --> 00:03:30,610 Unrecoverable in the sense that you can't do it remotely where somebody has to physically drive out there and power cycle it or physically go out there and replace it because it's broke so hard. 31 00:03:31,810 --> 00:03:36,210 And so why this, so this is also what happened. 32 00:03:36,210 --> 00:03:44,630 I was talking to a guy , this is the whole reason we have this talk, and he was a fellow security researcher and he said , he said, you have ICS data on your network. 33 00:03:44,630 --> 00:03:45,790 And I told him, no, I don't. 34 00:03:45,790 --> 00:03:47,090 He says, you do, go find it. 35 00:03:47,090 --> 00:03:51,110 And so after he and I left this conference, I went back and I found this ICS data. 36 00:03:51,130 --> 00:03:56,710 I found these attacks coming in and I didn't have a convenient way to figure out what was happening with them. 37 00:03:57,310 --> 00:04:01,930 I saw the data, I could see the raw bytes, but I didn't know what they meant, I didn't know what they were doing. 38 00:04:01,950 --> 00:04:04,430 And I thought, this is probably a problem for everybody. 39 00:04:04,650 --> 00:04:12,690 Like, how do I explain to my customer, hey, you know what, you, you know, foreign IP tried to hit you 400,000 times to turn off your PLC. 40 00:04:12,990 --> 00:04:16,570 I mean, none of them were successful, of course, but it doesn't stop the attacks. 41 00:04:18,350 --> 00:04:23,650 So I would like to turn my time over for James to explain to you the Purdue model and how Zeek works. 42 00:04:25,370 --> 00:04:30,830 Yeah, so the Purdue model's been around for a while, 1970-ish, I think. 43 00:04:31,370 --> 00:04:39,270 And really what it is, it's just a way to describe how these ICS systems tie into the business network. 44 00:04:39,310 --> 00:04:46,970 So if you look at this, you can see down here at level zero, you have the physical devices that are actuating physical processes. 45 00:04:47,050 --> 00:04:53,450 So these are things like pumps, sensors, belts, things like that. 46 00:04:53,990 --> 00:04:59,710 And then level one here, you have the control devices that are controlling those physical processes. 47 00:05:00,090 --> 00:05:11,490 And then as you work your way up the network, you get up to the business analytics portions that are consuming this data to be used for making business decisions and risk decisions, right? 48 00:05:11,970 --> 00:05:16,270 And so what we're talking about is defense, right, of the network. 49 00:05:16,270 --> 00:05:30,250 And so what we want to look at is the basic stuff that you do with any network, figuring out where to do segmentation and where to create those security boundaries to isolate that data and protect it, right? 50 00:05:30,250 --> 00:05:35,350 And so if you look here, we have some notional firewalls that are in this diagram, right? 51 00:05:35,350 --> 00:05:46,250 And so those are some good places to place spans or taps or what have you, however you're going to monitor this network, um, to capture that data and see what is going on. 52 00:05:50,030 --> 00:05:58,710 So why did we choose Zeek as opposed to some other tool for using to monitor and defend ICS data? 53 00:05:58,810 --> 00:05:59,950 A couple reasons. 54 00:05:59,950 --> 00:06:06,630 Um, Zeek is open source, so that means it's freely available for anyone to use and it has a very active, uh, development community. 55 00:06:06,630 --> 00:06:08,650 It's also very well documented. 56 00:06:08,650 --> 00:06:14,190 There's tons of white papers, talks, and, uh, uh, whatnot to go look at. 57 00:06:14,290 --> 00:06:18,770 Additionally, Zeek comes with a turn complete scripting language. 58 00:06:19,010 --> 00:06:26,090 The Zeek scripting language is event driven and it's purpose built for network communications. 59 00:06:26,430 --> 00:06:35,130 Um, so it's a, it's a great tool for building additional detections on top of, uh, and other, and tying it into your other systems. 60 00:06:35,670 --> 00:06:40,330 Um, additionally, it has the ability to create custom parsers. 61 00:06:40,330 --> 00:06:42,270 So that's what we're talking about today. 62 00:06:42,350 --> 00:06:52,790 Um, so you can go into Zeek and modify it for your purposes and build a parser to monitor the protocols that you want to, that you care about. 63 00:06:53,310 --> 00:07:01,550 Additionally, Zeek is fully extensible because of the scripting language and all the other stuff and all the other tools, uh, the community has built. 64 00:07:01,550 --> 00:07:08,150 It's very easy to plug into your existing network and get those logs into your sim or to do some sort of active defense with. 65 00:07:11,460 --> 00:07:16,360 So creating parsers, um, we sort of took two approaches here, right? 66 00:07:16,360 --> 00:07:20,220 You need to write your own or you can find someone else's and we sort of did both. 67 00:07:20,420 --> 00:07:28,120 Um, so the protocol we chose to write our own on is, uh, EtherNet IP and SIP. 68 00:07:28,160 --> 00:07:35,620 EtherNet IP, uh, is the session layer particle for SIP, which is the common industrial protocol. 69 00:07:36,360 --> 00:07:49,860 Additionally, um, we went around and tried to find what other tools and things people had done and, uh, this researcher, uh, Dane Wolin wrote, uh, S7 protocol that we also used. 70 00:07:50,800 --> 00:07:55,900 Uh, I should say S7 is the protocol that's used for Simmons PLCs. 71 00:07:59,170 --> 00:08:01,990 So creating a Zeek parser. 72 00:08:01,990 --> 00:08:08,750 So we aren't going to dive into the deep, nitty gritty details, but we'll cover it over, uh, sort of a high level overview. 73 00:08:09,070 --> 00:08:13,490 Um, so first thing you need to do is go grab Zeek, right? 74 00:08:13,490 --> 00:08:19,870 So you can go to GitHub, find Zeek and just get clone that sucker and you'll have it there. 75 00:08:20,150 --> 00:08:29,370 Additionally, other things you want to do, um, Vlad, who's a member of the Zeek developer community, has this BINPACK quick start script. 76 00:08:29,370 --> 00:08:30,810 It's just a Python script. 77 00:08:30,810 --> 00:08:37,270 What that will do for you is it'll create the boilerplate, uh, files and code that you need to get started writing a protocol. 78 00:08:37,690 --> 00:08:41,110 And then after that, you need to write a protocol. 79 00:08:41,310 --> 00:08:46,090 Uh, Zeek protocols are written in a high level language called BINPACK. 80 00:08:46,150 --> 00:08:50,950 And so BINPACK is purpose built for, uh, describing protocols. 81 00:08:51,210 --> 00:09:02,450 Um, and so you're just going to describe the structures in the protocol and then you're going to tie that into the events and, uh, at a high level that's what's going on. 82 00:09:02,530 --> 00:09:08,610 And then after that, you're going to run it and it's probably not going to work and you're just going to keep iterating. 83 00:09:11,520 --> 00:09:14,140 So this is what BINPACK looks like. 84 00:09:14,220 --> 00:09:21,540 Um, so you can see here we have a couple different things going on. 85 00:09:21,600 --> 00:09:29,600 So this top level structure here is the ethernet IP header that the two protocols we just mentioned use. 86 00:09:29,740 --> 00:09:34,840 And we are describing the different values and where they lie in that structure. 87 00:09:34,840 --> 00:09:42,320 So for instance, it has a command value that will tell, uh, that describes what the command is that is coming across the wire. 88 00:09:42,320 --> 00:09:51,680 And then the length variable just says, hey, expect this much data in the, uh, SIP, in the SIP PDU that's to follow. 89 00:09:51,740 --> 00:09:53,960 And then so on and so forth. 90 00:09:54,320 --> 00:09:58,400 And then right below that, uh, we have a case statement. 91 00:09:58,400 --> 00:10:06,820 And the case statement is just saying, uh, whether the data is from the originator or the responder. 92 00:10:07,020 --> 00:10:12,500 And so in this case, uh, and then it's just passing it to another data structure here. 93 00:10:12,500 --> 00:10:16,920 Either e- ethernet IP request or ethernet IP response. 94 00:10:17,280 --> 00:10:22,220 And then finally, down here at the bottom, we have the ethernet IP request. 95 00:10:22,220 --> 00:10:30,120 And here we're calling, uh, another case statement for the command value that's up in the ethernet IP header. 96 00:10:30,140 --> 00:10:35,460 And so we're just looking at what value is in there to identify what the command is. 97 00:10:35,460 --> 00:10:39,940 And then passing that along further into the protocol, uh, structure. 98 00:10:40,240 --> 00:10:43,160 So in a nutshell , that's how BINPACK works. 99 00:10:43,160 --> 00:10:47,880 There's a little bit more with it in terms of then getting those events into the script layer. 100 00:10:47,880 --> 00:10:53,580 But, uh, that's, that's a, that's our quick five minute intro to BINPACK. 101 00:10:56,930 --> 00:10:59,810 Alright, so I'm gonna cover, cover what we did with that data. 102 00:11:00,050 --> 00:11:05,290 The, so off of, what's that thing? 103 00:11:06,270 --> 00:11:07,030 That, oh. 104 00:11:07,030 --> 00:11:10,270 So off of eBay, years ago, James had bought a Siemens PLC. 105 00:11:10,590 --> 00:11:14,490 And we're like, hey, you know, let's, let's blow this thing up, see what happens. 106 00:11:14,810 --> 00:11:25,410 And so, as far as the S7 protocol parser goes, I, I took a good hand to it for about 35 hours and then, and then realized somebody else had done all the work and felt dumb. 107 00:11:26,330 --> 00:11:28,290 And load it up and it worked great. 108 00:11:29,070 --> 00:11:37,870 So, first thing we did, so after that, when we decided, hey, let's break into this thing and blow it up, the, it didn't have an IP and we couldn't figure out how to give it an IP. 109 00:11:38,170 --> 00:11:40,650 So eventually we landed on the Siemens software portal. 110 00:11:40,650 --> 00:11:45,570 At one point, Siemens had sent us an email saying they couldn't verify we were American and they wouldn't let us download any of their software. 111 00:11:46,430 --> 00:11:51,490 We downloaded, we finally got this one called the TIA portal and we set the IP on the PLC. 112 00:11:51,490 --> 00:11:55,370 And it seems like this one liner, like, download the software, set the IP, right? 113 00:11:55,370 --> 00:11:58,170 This is like 30 hours into our project. 114 00:11:59,970 --> 00:12:07,670 The next thing I found is there was a, this guy, Dark LBP, he doesn't, I don't, I don't know any more data than that from his GitHub. 115 00:12:07,990 --> 00:12:09,890 He created this thing called ICSploit. 116 00:12:09,950 --> 00:12:14,330 It's a creative use of Scapey and Python to create custom attacks on PLCs. 117 00:12:14,530 --> 00:12:16,810 And it already has pre-built attacks for S7. 118 00:12:16,970 --> 00:12:18,350 So that worked fantastic. 119 00:12:18,350 --> 00:12:22,110 And he calls it ICSploit because it has a Metasploit style interface. 120 00:12:22,630 --> 00:12:26,390 But it, it's good if you just wanna, you know, if you wanna blow up your own PLCs from eBay. 121 00:12:27,410 --> 00:12:30,750 Then I started Wireshark. 122 00:12:30,750 --> 00:12:32,910 I captured data off my NIC. 123 00:12:33,150 --> 00:12:34,550 Then I ran the attacks. 124 00:12:35,090 --> 00:12:41,410 And then I took that data, fed it into Zeek that was running our S7 parser and we produced Zeek logs. 125 00:12:42,830 --> 00:12:46,650 So what this is, is this is ICSploit giving me data back, right? 126 00:12:46,650 --> 00:12:48,710 So this is a scanning style attack. 127 00:12:49,090 --> 00:12:52,530 And you can tell it what rack and what slot, etc. 128 00:12:52,530 --> 00:12:55,230 And it said it found these two vulnerable spots. 129 00:12:55,230 --> 00:12:56,730 Slot 0 and slot 1. 130 00:12:58,070 --> 00:13:04,850 The IP we set for our Siemens PLC was 192.168.38.200. 131 00:13:06,090 --> 00:13:09,890 The, so this is what, as an attacker you say, oh look, there's some stuff. 132 00:13:09,890 --> 00:13:11,330 I got, I got some data. 133 00:13:12,230 --> 00:13:15,210 There's, you know, so this is say, here's where I launched my attacks. 134 00:13:15,690 --> 00:13:21,370 This order code on there will give, you know, if you go and search, it gives you insight about what type of PLC it is. 135 00:13:22,270 --> 00:13:23,830 And this is what Zeek looks like. 136 00:13:23,830 --> 00:13:25,310 There's three type of logs represented here. 137 00:13:25,310 --> 00:13:31,350 The con log, which is your connection log, your S7 setup communication log, and on the bottom your S7 user data log. 138 00:13:31,430 --> 00:13:35,150 Now, the first field there is your, is your UID. 139 00:13:35,150 --> 00:13:38,910 And Zeek is really important because your UID ties all your different logs together. 140 00:13:39,330 --> 00:13:43,050 And so all the blue logs go with blue logs and yellow logs go with yellow logs. 141 00:13:43,050 --> 00:13:47,010 And if they aren't highlighted, it's because they were scanned and nothing returned. 142 00:13:47,130 --> 00:13:53,750 So you can see in the, in the column just before it says SRSTR, everywhere where it has zero means there was zero bytes returned. 143 00:13:53,750 --> 00:13:55,590 So it got, it got no, no return. 144 00:13:55,590 --> 00:13:59,750 So on my big scan, those are the ones that didn't return, which is why they're not highlighted. 145 00:13:59,750 --> 00:14:03,250 They're included just to say, hey, I scanned more than just that one area. 146 00:14:04,210 --> 00:14:09,030 So in the, then in the 7 setup con log, it shows you there was a call for a job. 147 00:14:09,030 --> 00:14:10,190 The job was acknowledged. 148 00:14:10,190 --> 00:14:14,570 And then the user data, it sends these SLS, SZL requests and response. 149 00:14:14,730 --> 00:14:26,750 And one of the things about Siemens PLCs is it doesn't matter what kind of protections you have on them, you can, you can still read, you can send read requests to the SZL and it'll respond to you every time. 150 00:14:26,830 --> 00:14:31,890 You may not be able to do any much more after that, but at least you know that you have a live target. 151 00:14:34,720 --> 00:14:37,200 The next thing I did is we tried to turn it on and off. 152 00:14:37,720 --> 00:14:44,060 So as you can see here, the command description, 1 to start the PLC or 2 to stop the PLC. 153 00:14:44,500 --> 00:14:49,660 So I set the slot to 1 because that's, that's the slot that was vulnerable. 154 00:14:50,180 --> 00:14:52,200 I set the command to 1 and then I ran it. 155 00:14:52,740 --> 00:14:57,800 And then it, then as you can see, running module, target is alive, sending packet to target, start PLC. 156 00:14:58,080 --> 00:15:01,000 So me as the attacker say, oh cool, the, the PLC started. 157 00:15:01,480 --> 00:15:06,220 And then I changed the command to stop it and this is, oh okay, the PLC stopped now. 158 00:15:06,980 --> 00:15:10,100 Now, turning on and off, right, doesn't seem like a major attack, right? 159 00:15:10,100 --> 00:15:12,320 You turn PLC, you turn it on, you turn it off, big whoop. 160 00:15:13,060 --> 00:15:19,760 So a couple years ago, one of the national labs had this giant generator just like, I don't know, like a billion kilowatts. 161 00:15:19,760 --> 00:15:20,520 I don't, it's not that high. 162 00:15:20,520 --> 00:15:21,380 I don't know how much it was. 163 00:15:21,380 --> 00:15:22,400 It was a giant, it was large. 164 00:15:22,840 --> 00:15:24,560 And they turned it on and off rapidly. 165 00:15:24,560 --> 00:15:25,180 Bum, bum, bum, bum. 166 00:15:25,180 --> 00:15:31,180 And it blew up because they started it and stopped it and started it and stopped it and it blew the heck up. 167 00:15:31,420 --> 00:15:42,860 And so, so maybe not a catastrophic explosion to kill everybody in the plant, but it's significant enough to require, who knows the amount of down time to get the heavy equipment in there to replace that generator. 168 00:15:43,500 --> 00:15:51,760 And, and besides like, any time your PLC just take rogue, wild turn on and off statements, like it's ridiculous. 169 00:15:51,760 --> 00:15:52,640 It should never happen. 170 00:15:54,860 --> 00:15:55,640 Here's what we have. 171 00:15:55,640 --> 00:15:57,040 I split it up in two parts. 172 00:15:57,300 --> 00:16:00,860 The top part I call turn on and the top, bottom part I call turn off. 173 00:16:01,420 --> 00:16:03,960 And again, it's the same, the first two logs are the same. 174 00:16:04,020 --> 00:16:12,700 Your con log, which is your connection log, then your setup communication, and then the bottom one that's new for this type of, of log source is your PLC function. 175 00:16:13,940 --> 00:16:18,440 So, main thing in your connection log, data was, was processed. 176 00:16:18,440 --> 00:16:20,880 It went, you got bytes to and from. 177 00:16:21,040 --> 00:16:25,440 Then you have the job and the job was acknowledged in the setup, in the, yeah, the setup communication. 178 00:16:25,580 --> 00:16:29,460 And the last part, it calls this program called P program and then it says empty. 179 00:16:29,540 --> 00:16:31,720 Because we didn't actually have a program in there. 180 00:16:32,200 --> 00:16:35,200 We, uh, we did, but we deleted it out. 181 00:16:35,820 --> 00:16:40,060 Our PLC wasn't connected to anything during this, during this setup. 182 00:16:40,060 --> 00:16:43,960 We, uh , I was just happy that we could turn it on and turn it off. 183 00:16:44,180 --> 00:16:45,460 And the turn off is the exact same. 184 00:16:45,460 --> 00:16:47,160 There's data in the connection log. 185 00:16:47,520 --> 00:16:49,500 We have the communication. 186 00:16:49,500 --> 00:16:50,060 There's a job. 187 00:16:50,060 --> 00:16:51,260 We acknowledge the job. 188 00:16:51,440 --> 00:16:52,880 And then it stopped. 189 00:16:53,040 --> 00:16:54,240 PLC stopped. 190 00:16:55,180 --> 00:17:10,940 And so, so how this is relevant to an analyst is rather than just seeing raw data on the wire, just bits, they're trying to figure out, like, if it was UDP and like DNS, if, if I give an analyst raw DNS, they could probably tell me what the IP it came from, 191 00:17:10,940 --> 00:17:14,360 what the IP requested it, what the IP was returned, because they know that. 192 00:17:14,360 --> 00:17:15,100 They live in that space. 193 00:17:15,100 --> 00:17:18,140 The TCP IP stack is, is daily stuff, right? 194 00:17:18,140 --> 00:17:23,380 But if I say, hey, here's some raw bytes from a PLC turn off command for an S7 protocol. 195 00:17:23,500 --> 00:17:25,500 And the analyst is like, yeah, that's cool, bro. 196 00:17:25,500 --> 00:17:27,720 You know, I, I hope it's not broke. 197 00:17:29,000 --> 00:17:29,840 Generally, right? 198 00:17:29,840 --> 00:17:42,740 In general, like, because we're not a PLC shop, but maybe if you have a PLC shop, you have guys dedicated just to Siemens PLCs and just to Allen Bradley PLCs and just only guys who study Modbus, right? 199 00:17:43,940 --> 00:17:46,640 Does anybody, is that a thing? 200 00:17:48,160 --> 00:17:49,300 It is? 201 00:17:50,160 --> 00:17:51,420 No, no, no. 202 00:17:51,660 --> 00:17:57,100 Where you have a Modbus guy on the network analyzing only Modbus data and he's like. 203 00:18:00,340 --> 00:18:02,620 So, so that's what we had. 204 00:18:02,620 --> 00:18:03,380 Those are attacks we ran. 205 00:18:03,380 --> 00:18:06,260 We scan and we turned it off. 206 00:18:07,580 --> 00:18:11,740 And I will now turn the time over for, to James for our conclusion. 207 00:18:13,020 --> 00:18:16,640 So, we're blue team guys, right, through and through. 208 00:18:16,640 --> 00:18:19,320 We enjoy finding bad guys. 209 00:18:19,320 --> 00:18:24,020 We enjoy seeing them attack our networks and then null routing their stuff. 210 00:18:24,140 --> 00:18:26,120 That's, that's what we do, right? 211 00:18:26,180 --> 00:18:31,100 So, uh, I think from our perspective, we think this stuff's really cool. 212 00:18:31,100 --> 00:18:33,100 We hope you guys think it's cool too. 213 00:18:33,140 --> 00:18:40,820 Um, we encourage you, if you think it's cool, to go look at Zeek, uh, maybe contribute, write some parsers of your own. 214 00:18:40,860 --> 00:18:48,540 And then additionally, uh, if you have guys have novel detections you can think of, uh, Zeek's a great tool to build detections in. 215 00:18:48,540 --> 00:18:50,720 And, uh, I think that's all we have. 216 00:18:50,720 --> 00:18:53,440 Yeah, does, are there any questions? 217 00:18:53,440 --> 00:18:56,320 Does anybody care to know more about my PCAP? 218 00:18:58,480 --> 00:18:59,640 Alright, thank you guys. 219 00:18:59,640 --> 00:19:00,340 Thanks.