WEBVTT

00:00.000 --> 00:01.920
So my name is Joe Bingham.

00:01.920 --> 00:05.440
I'm going to talk about some ICS vulnerabilities that we found.

00:05.940 --> 00:08.900
I'm on the zero day research team at Tenable.

00:09.100 --> 00:11.940
There's only about five or six of us.

00:12.500 --> 00:21.440
And what we're going to talk about is in the last year or so we've been looking at a lot of ICS products, different SCADA targets for software and hardware.

00:21.800 --> 00:26.600
And we found about a dozen critical vulnerabilities just kind of scattered across the board.

00:27.700 --> 00:35.740
And they're critical vulnerabilities because they provide unauthenticated or pre-auth remote code execution in the affected systems.

00:36.020 --> 00:45.880
So as we go through this talk here, I'll describe four of them in a little bit of detail and then we'll blow up a power plant.

00:49.290 --> 00:57.730
All right, so the first one that we'll look at is in Siemens Step 7, which Step 7 has been around forever.

00:57.730 --> 01:03.390
They rebranded it as TI Portal and it's automation services.

01:03.390 --> 01:11.990
It's used in all aspects of ICS development and operation from design phase to implementation and all the way down to operations.

01:13.510 --> 01:16.830
So TI Portal has a suite of simulation tools.

01:16.830 --> 01:20.070
It does diagnostics and telemetry.

01:20.070 --> 01:21.550
It does energy management.

01:21.550 --> 01:27.790
So they use it in operation in all sorts of different industries, down on the plant floor, just for monitoring equipment.

01:28.110 --> 01:34.830
And it's built for use by engineers, built for the integrator, as well as built for the operator personnel.

01:35.350 --> 01:41.710
So the vuln that we found in the software exists in the authentication package of the server.

01:41.710 --> 01:50.810
It has a Node.js server and TI Portal implements functionality for authentication, for authenticating web users and administrators.

01:51.310 --> 02:04.290
After authentication, the SSL session is switched over to WebSockets, but they don't use the token that's validated in authentication in the WebSockets session.

02:04.330 --> 02:12.690
So, of course, you can just skip HTTP authentication and start sending WebSockets commands directly to the server and it will process them.

02:12.710 --> 02:17.170
And, of course, all administrator functionality is included in the WebSockets protocol.

02:18.050 --> 02:19.430
So what can you do with that?

02:19.430 --> 02:20.910
You can do a number of things.

02:21.010 --> 02:25.350
You can basically do anything that an administrator would want to do on the system.

02:25.790 --> 02:33.710
But the best thing that an attacker would want to do is just start a firmware update and you can specify the firmware update server.

02:33.710 --> 02:38.410
So basically you can just ask the server to execute any remote URL.

02:38.410 --> 02:48.410
You could also do a couple other things like modify permissions for users, create new users, or you could just change application proxy settings, collect system information.

02:48.970 --> 02:57.650
So we have a disastrous security hole in this Siemens software that's used on the plant floor in critical operations.

02:58.030 --> 03:05.910
And as we go through these vulns, you know, I'm going to have different POCs and those are all on our tenable GitHub repository.

03:05.910 --> 03:08.090
You can find exploits for all of these vulnerabilities.

03:08.710 --> 03:15.050
And I guess while we're talking about Siemens, earlier today at BlackHat, we had the University of Tel Aviv.

03:15.050 --> 03:28.710
We're looking at the Symatic PLCs and they found some other crazy vulnerabilities in those that, you know, basically anyone can come and reprogram the PLCs if it's set up with the default permissions , because they all share private keys.

03:28.850 --> 03:32.290
So Siemens kind of, I don't know, I don't know what to say about Siemens.

03:33.150 --> 03:37.130
Second one is in Schneider Electric that we'll talk about.

03:37.290 --> 03:38.970
Indisoft Web Studio.

03:38.970 --> 03:49.110
So earlier this year, we found that Indisoft has several vulnerabilities, including one that allows attacker to send unauthenticated commands to the application.

03:49.130 --> 03:57.490
And specifically this command 66 is used to configure the database connection for Indisoft.

03:57.490 --> 04:01.830
And in many of the code paths, the file name can actually be user supplied.

04:01.830 --> 04:10.550
So in this command 66 message, an unauthenticated attacker can specify a database configuration file and ask the server to update from that file.

04:10.550 --> 04:17.590
And then the Indisoft server parses the malicious update file and executes these wrap brackets as WinExec.

04:17.590 --> 04:26.790
So an attacker can specify arbitrary commands inside of this database configuration file to run remote code on any Indisoft Web Server Studio.

04:28.650 --> 04:47.410
And here's, so our proof of concept for this was just basically to, in Python, sets up a local SMB server, requests the Indisoft Web Studio to trigger a database configuration update pointing to the controlled SMB server.

04:47.410 --> 04:50.990
The server requests the database configuration file and then runs a command based in it.

04:50.990 --> 04:53.990
And we just used it to pop a calculator application.

04:55.890 --> 04:58.230
And that's available on the, on the GitHub.

04:58.230 --> 04:59.390
All of these will be.

04:59.810 --> 05:03.770
Alright, so the third one, also in Schneider Electric, but in hardware.

05:03.770 --> 05:10.310
So the Moticon Quantum PLC are kind of like a ubiquitous PLC hardware used all over the place, different industries.

05:10.390 --> 05:13.370
And they're, they're favorites because they're modular.

05:13.370 --> 05:14.570
You can kind of plug and play them.

05:14.570 --> 05:16.490
They have all sorts of different modules in them.

05:17.550 --> 05:23.190
They're kind of interchangeable, slide them into the housing, depending on what the needs of your application are.

05:23.230 --> 05:37.290
So one of the vulnerabilities that we found in these PLCs, specifically in the communications PLC, is that there's authentication bypass in the communications module, which would allow an attacker to administer the device without credentials.

05:38.410 --> 05:40.350
And here's the exploit for that.

05:41.310 --> 05:42.050
There it is.

05:42.050 --> 05:43.470
Pretty easy, right?

05:43.470 --> 05:46.550
So, apparently zero days easy.

05:46.550 --> 05:59.610
This applica-, this PLC uses a, just the hidden, hidden, hidden service API of the communications device to just change the administrator, administrator password without authentication, without authentication.

06:02.040 --> 06:03.860
Alright, last one.

06:04.160 --> 06:09.120
This vulnerability is in Rockwell Automation, RSLinx.

06:09.240 --> 06:18.600
And RSLinx classical is, it basically implements Ethernet IP and encapsulates the common industrial protocol SIP messages.

06:18.620 --> 06:25.480
So then in their implementation, the packet has a 24 byte header, followed by some command specific data.

06:25.680 --> 06:29.860
Now the header lists the command and the length of the command specific data .

06:30.380 --> 06:46.820
So the vulnerability exists, it's a stack overflow caused by a malformed connection path where there's a function in the library engine, engine.dll library in RSLinx, which parses a connection path to extract a port path and stores it in a buffer on the stack.

06:46.820 --> 07:01.000
The length isn't verified and so you can specify up to 256 bytes of the port path and overflow the stack address and in 32 bit windows I think the return address is like 200 bytes or so from the beginning of the buffer.

07:01.000 --> 07:04.660
So a pretty easy, pretty easy stack overflow.

07:05.180 --> 07:06.580
Alright, that's it.

07:06.640 --> 07:08.340
I hope that wasn't too bad.

07:08.340 --> 07:15.160
So let's look at the fun part, which will be the application of these vulnerabilities and I chose to kind of look at a nuclear power plant.

07:15.160 --> 07:16.120
So let's see.

07:17.560 --> 07:22.600
First things first, let me turn you guys into nuclear physicists in one minute.

07:22.940 --> 07:28.680
Nuclear fission, it's a process where a large nucleus splits into two smaller nuclei.

07:28.680 --> 07:32.480
So when it splits, it releases energy, right?

07:32.480 --> 07:38.160
And in the case of nuclear fission in these power plants, we use uranium 235.

07:38.160 --> 07:45.340
Uranium 235 splits into krypton and it splits into barium and with that it releases three more neutrons and it releases heat.

07:45.380 --> 07:49.600
Each of those neutrons can start another chain reaction and that's fission, that's it.

07:49.600 --> 07:57.840
So uranium 235 is a really nice isotope of uranium where 238 is the naturally occurring one.

07:57.980 --> 08:10.660
So when you hear about people enriching uranium, they're adding more 235 to the 238 natural fuel and that makes it more chain reactive.

08:10.860 --> 08:21.700
So remember the neutrons that are produced, those three neutrons in the reaction, those are exactly how the fission reaction is controlled and those are like the most important part of the chain reaction.

08:22.800 --> 08:34.720
So we know that the fission reaction creates heat and the heat is used in these power plants to boil steam, to boil water, which creates steam and then the steam turns a turbine and that's it.

08:34.720 --> 08:35.840
That's how the power is created.

08:35.840 --> 08:36.920
So one minute, right?

08:36.920 --> 08:37.660
You're experts?

08:37.900 --> 08:39.840
I don't know why they even teach this in school.

08:39.840 --> 08:40.840
You can just Google it.

08:40.840 --> 08:43.440
Like I don't know, why is nuclear engineering a thing?

08:44.180 --> 08:45.100
Just kidding.

08:45.100 --> 08:45.620
Okay.

08:45.620 --> 08:49.320
So the key players in the nuclear reactor, for number one, we have the fuel.

08:49.460 --> 08:52.020
That's the basis of the fission chain reaction.

08:52.180 --> 08:56.880
In nuclear power, it's uranium in general, sometimes plutonium, but almost all the time uranium.

08:57.020 --> 08:58.460
That's the thing that releases heat.

08:58.460 --> 08:59.760
It's the key element of fission.

08:59.760 --> 09:01.820
We have the moderator.

09:01.920 --> 09:06.720
That guy's job is to just slow down the fission reaction by absorbing neutrons.

09:06.720 --> 09:14.780
Each of those three neutrons that came out when the nucleus splits, the moderator stops maybe two of those to continue the chain reaction.

09:15.320 --> 09:18.860
Now the coolant, its only job is just to take heat away from the core.

09:18.860 --> 09:19.320
That's it.

09:19.320 --> 09:20.620
The heat is the energy.

09:20.720 --> 09:23.260
And then the fourth guy is the control.

09:23.260 --> 09:24.720
That's the referee in the game.

09:24.720 --> 09:33.540
So you have, when the game starts getting too crazy, the fission reaction is getting out of control, you drop in the control elements.

09:33.600 --> 09:39.160
And so the control elements will generally be cadmium, hafnium, boron.

09:39.160 --> 09:48.180
All of those materials absorb massive amounts of neutrons, so they just completely stop the fission reaction in seconds or minutes, almost always within seconds.

09:48.880 --> 09:51.100
And we'll talk about those more in detail.

09:51.460 --> 09:56.420
But let's get into, first, some of the different designs in nuclear reactors.

09:56.420 --> 09:59.340
There's a lot of different designs.

10:00.020 --> 10:02.340
And I'll go through like four or five of them.

10:02.640 --> 10:06.080
The first one is the pressurized water reactor, or PWR.

10:06.220 --> 10:12.180
This is by far the most prevalent reactor that's in use in the entire world.

10:12.700 --> 10:17.000
Almost all of the power plants in the US are these.

10:17.000 --> 10:18.660
They're used in France.

10:18.660 --> 10:20.840
They're also used in Japan, Russia, China.

10:20.920 --> 10:26.660
And as time goes on, they're more and more and more of them go online just because they're so stable.

10:28.320 --> 10:38.440
And then its little brother is the boiling water reactor, which is basically the same as the pressurized water reactor, except that steam isn't created inside of the core.

10:38.540 --> 10:41.540
Steam is actually created in a separate heat exchanger.

10:41.540 --> 10:43.920
So the reactor is fully liquid.

10:46.660 --> 10:51.960
All right, now for the PWR, I'll talk a little bit about the safety systems.

10:52.000 --> 10:59.340
This is a diagram of an existing one in Japan, the Kashiwazaki Kariwa BWR in Japan.

10:59.340 --> 11:02.460
It came online within the last decade or so.

11:02.460 --> 11:06.900
And the control systems and the instrumentation, they're all on the same network.

11:06.900 --> 11:15.220
Of course, it's an air gap network separate from the corporate intranet and even one step further from the wide internet.

11:15.560 --> 11:26.340
And so you can see that in this diagram, the control systems are all fully automated, fully computer controlled.

11:26.340 --> 11:31.540
They have separate response systems, and they have redundant safety systems in them.

11:31.540 --> 11:42.820
The emergency core cooling system, which is in the lower left, the ECCS, and then the SCRAM control rod insertion, those are the two referees, the control elements to shut down the reaction.

11:42.820 --> 11:45.340
That's right below it to the right of the ECCS.

11:47.820 --> 11:53.580
Third type of reactor design is the pressurized heavy water reactor.

11:53.580 --> 11:58.140
And they call it, it's almost all of them are in Canada, they call it the CANDU.

11:58.140 --> 12:00.600
It's kind of a modification of the PWR.

12:01.140 --> 12:13.000
And it's a little bit of a different design because instead of light water, which they call are the PWR and the BWR, like light water reactors, it uses normal water, filtered water.

12:13.000 --> 12:18.700
These ones use heavy water, which is like deuterium, which is another hydrogen isotope.

12:18.820 --> 12:24.440
And deuterium already has the extra neutron that light hydrogen would have absorbed.

12:24.460 --> 12:29.080
So there's reduced neutron absorption, which makes it easier to sustain the chain reaction.

12:29.160 --> 12:31.360
And so that makes it so they can use a different kind of fuel.

12:31.360 --> 12:33.060
They don't have to use enriched uranium.

12:33.060 --> 12:38.240
So they can use naturally occurring uranium or lower concentration of enriched uranium.

12:38.820 --> 12:44.040
But the downside and the cost of that is that the fuel is cheaper.

12:44.040 --> 12:47.060
But on the other hand, the design is much less stable.

12:47.060 --> 12:58.080
So you end up with these circumstances where reactivity can increase as the water starts to boil in kind of these edge cases.

13:03.300 --> 13:25.580
And what that means is that an attacker that has modification access in this presumed attack scenario can actually control the safety systems to create a situation in the core where the fission reaction can occur in what they call a runaway fission reaction where reactivity increases and it's like a feedback loop.

13:25.580 --> 13:28.480
So as the temperature keeps going up, the fission reaction keeps going up.

13:28.480 --> 13:32.700
And that's exactly what happened in Chernobyl, if you're familiar with that.

13:34.160 --> 13:49.960
All right, so in the PWR, the PHWR, the Kandu nuclear power plant, because of those, you know, they're aware that they can have this reactivity runaway, obviously.

13:49.960 --> 13:54.960
So the safety systems are incredibly durable, so they say.

13:54.960 --> 14:06.560
This is a diagram here from the USNRC, the United States Nuclear Regulatory Commission generally does studies on what they call diversification in the safety systems.

14:06.560 --> 14:11.180
And diversification means that there are not common ways that they can fail, right?

14:11.180 --> 14:14.540
Like one vulnerability can't shut down both safety systems.

14:14.540 --> 14:22.860
So in this case, we have two referees, two of these safety systems, SDS-1, which is the absorption rods, which drop into the core, and they're made of boron.

14:22.860 --> 14:26.400
They drop into the core and completely shut off the fission reaction.

14:26.540 --> 14:42.360
And SDS-2, which is boric acid injection, where there's like several injectors on the side of the nuclear core, where they just spray in boric acid to increase the level of boron inside of the liquid, which also absorbs all the neutrons immediately stopping the fission reaction.

14:44.200 --> 14:53.860
So the point, I guess, is that the CANDU system relies on computer control through two of these redundant computers that manage information and alarms.

14:53.860 --> 14:55.700
They're all on the same network, though, right?

14:55.700 --> 14:58.760
So you still have this same access vector.

14:58.820 --> 15:02.880
But the two critical safety systems use different operating systems.

15:02.880 --> 15:06.140
They use different architectures and processor hardware.

15:06.140 --> 15:07.600
They use different languages.

15:07.600 --> 15:10.700
They're not allowed to use the same languages or executables.

15:10.700 --> 15:16.980
So for example, you know, the absorption rods will run on Windows and the boric acid injection runs on Linux.

15:17.200 --> 15:23.000
The, you know, SDS-1 runs with Fortran, for example, and SDS-2 runs with C++.

15:23.000 --> 15:26.340
So that's what they call diversification in nuclear power plants.

15:26.580 --> 15:37.140
So even so far, though, as being developed and coded by separate teams, so like the software will have same design parameters, but coded by different people and run by different teams.

15:37.300 --> 15:46.060
So in the end, you know, all it all it means to us is that you need, you know, one, maybe two more zero days to exploit the system, right?

15:46.060 --> 15:48.440
But don't worry, you can use some of the ones that we found.

15:49.980 --> 15:50.860
All right.

15:50.860 --> 15:54.680
The second to last reactor type is the AGR.

15:54.680 --> 15:55.620
I just have to mention it.

15:55.620 --> 15:58.760
It's, you know, like the fourth most popular one used.

15:58.920 --> 16:02.160
The advanced gas reactor, they use these in the UK.

16:02.320 --> 16:12.900
It uses natural uranium and they, you know, to deal with like this problem of liquid boiling in the core and that causing a problem, these, what they call void coefficients, increasing reactivity.

16:12.900 --> 16:15.660
They just said, let's not use liquid, we'll just use gas.

16:15.660 --> 16:20.060
So they use carbon dioxide in there as a coolant and you don't have to worry with stuff boiling.

16:20.060 --> 16:25.160
So there's no such thing as, there's no such thing as void coefficient issues.

16:25.880 --> 16:27.420
And it's also pretty stable.

16:27.420 --> 16:30.580
You know, it's comparable to the PWRs and the BWRs.

16:30.580 --> 16:33.000
And there's, yeah, those are in the UK.

16:33.980 --> 16:40.960
Then the last thing that obviously we have to mention is the Russian RBMK, which is just this horribly unstable design.

16:40.960 --> 16:43.140
They still use like three of them.

16:43.140 --> 16:44.180
That's a typo.

16:44.180 --> 16:46.100
I think there's only three of them in Russia.

16:46.420 --> 16:53.620
They use natural uranium, which you know, as temperature goes up, the uranium reactivity increases, which is a bad thing.

16:53.620 --> 16:56.400
It uses graphite as a moderator and water.

16:56.400 --> 17:09.740
It has a positive void coefficient, meaning that as the liquid in the core boils off and creates steam, you get, you get steam between the fuel rods instead of liquid, which increases reactivity.

17:09.820 --> 17:15.720
So as heat goes up, reactivity goes up, which is basically, that's why Chernobyl exploded again.

17:15.720 --> 17:17.320
You know, so horrible design.

17:17.320 --> 17:18.880
They're trying to phase all of these out.

17:18.880 --> 17:24.820
Russia starts, has started in the last decade or so putting PWRs, but they still have some of these in action.

17:26.360 --> 17:29.120
Okay, so attack scenario.

17:30.000 --> 17:32.460
I'm gonna, I think I have to start going a little faster here.

17:32.460 --> 17:34.000
So we got about 10 minutes.

17:35.200 --> 17:36.940
So the attack scenario, right?

17:36.940 --> 17:40.000
The network is going to be an air gap network.

17:40.000 --> 17:40.780
You want to protect it.

17:40.780 --> 17:45.460
You have all this critical, very fragile equipment on this network.

17:45.800 --> 17:47.460
So we're going to have it air gapped.

17:47.460 --> 17:54.500
So we need some kind of initial, initial infection into some adjacent network, which would be a corporate or employee network.

17:54.600 --> 17:57.900
And that's not too, it's fairly trivial , obviously.

17:58.140 --> 18:04.200
Once we're in the adjacent network, some kind of human interaction or other propagation zero day would allow us into their control network.

18:04.240 --> 18:10.660
And we've seen this before, like, I feel like I don't need to spend too much time on this, you know, Stuxnet use Windows Vuln over USB to jump the gap.

18:10.700 --> 18:16.380
And then there's a lot of different ways that we've seen in other malware like Triton that, that do this.

18:16.620 --> 18:29.100
So once we're in the network, and we're running on an operator panel, for example, one of the, or, or one of the peripheral systems, we need to get onto a controller.

18:29.100 --> 18:35.100
That's where we actually have access to the PLCs, access to the control network, access to some of the safety systems.

18:35.900 --> 18:38.260
So what we do is we use another vulnerability.

18:38.260 --> 18:53.480
For example, the first one that I talked about, the one of Siemens, in general, you have these controllers on the operational floor, which are interfacing with the PLCs for data collection for telemetry and in the development cycle for programming the PLCs.

18:53.480 --> 19:01.120
So we use that Siemens vulnerability immediately to jump from the operator interface, this peripheral device, onto the, onto the controller.

19:02.480 --> 19:06.920
And once you have access to the controller, modifying PLC logic becomes trivial.

19:06.980 --> 19:11.340
So in production environments, you could, you can accomplish that in a number of different ways.

19:11.340 --> 19:20.560
The malware implant could wrap, for example, the communications through the controlling server to modify control flow for automatic function changes, which is similar to what we saw with Stuxnet.

19:21.340 --> 19:28.960
And then for, for our attack on the power plant, we just need to be able to stop the coolant pumps, number one, that reduces heat exchange out of the core.

19:28.960 --> 19:30.020
That's the most dangerous thing.

19:30.020 --> 19:33.400
As the core temperature increases, it's going to start to melt down.

19:33.400 --> 19:45.520
And in other extreme cases of the horrible design, designs that I talked to you about, some of the really bad designs, fission reactivity increases, which is, you know, within minutes, you could have some disastrous explosion.

19:46.460 --> 19:48.140
So we need to stop the coolant pumps.

19:48.140 --> 19:48.800
That's number one.

19:48.800 --> 19:50.400
Stop heat transfer out of the core.

19:50.400 --> 19:55.660
And then secondly, we need to be able to, to withdraw control rods to increase fission.

19:55.660 --> 20:04.060
And then thirdly, we need to be able to stop the safety systems, the safety systems where the control rods are inserted or boric acid is sprayed in.

20:04.060 --> 20:15.900
And those are on different redundant systems, but they all go through some common logic collector, which ends up being the thing that decides whether or not to turn on the safety systems.

20:18.180 --> 20:27.620
So another integral part of creating a successful attack on one of these power plants is by providing false telemetry to the operators.

20:27.620 --> 20:41.980
So you provide them the illusion of control to the people that are monitoring the safety systems, that are monitoring the monitoring the temperature controls and the pressure, the pressure displays, you tell them everything's okay inside of the core, while while in reality,

20:41.980 --> 20:44.660
you know, things are reaching some critical threshold.

20:44.660 --> 20:46.800
But during that time period, you don't want anyone to respond.

20:46.800 --> 20:56.680
So you buy yourself some time to create this awful situation where fission can go on to this runaway, runaway path, runaway path.

20:56.760 --> 21:09.040
So it can happen, you can do that by simulating logic inside of the implant to send pre-calculated temperatures or even, you know, real time simulated temperatures and pressure and power readings based on the operator's commands.

21:09.480 --> 21:19.640
And so as the plant operator attempts to move control rods, for example, to control the fission reaction, the implant sends back simulated signals to say, yes, the control rods are moving, even though we have control of them.

21:21.260 --> 21:21.860
All right.

21:21.860 --> 21:28.900
And then the last and other critical part of the attack is to disable the critical and redundant manual and automatic safety measures.

21:28.900 --> 21:34.480
So the malware can replace logic inside of the ECCS and as well as the SCRAM control rod insertions.

21:34.480 --> 21:38.320
And those are the two independent and diverse safety systems that we talked about.

21:38.320 --> 21:40.280
That's an NRC regulation.

21:40.280 --> 21:41.280
All power plants do that.

21:41.280 --> 21:49.840
They have separate, but you know, separate, not equal, just separate systems which are able to completely shut down the fission reaction.

21:50.900 --> 22:04.360
And by disabling the safety systems, we allow, you know, that extra five minutes or even an hour in some cases to provide the reactor core to set it onto this path where it's going to eventually melt down or explode.

22:07.400 --> 22:13.780
So worst case scenario, I'll talk about the RBMK since there's still three of them in action.

22:13.780 --> 22:17.440
They're all in Russia, but they're extremely unstable.

22:17.440 --> 22:27.520
They have this design parameter where fission can end up on this thermal feedback loop which makes fission just run out of control.

22:28.340 --> 22:35.280
They rely entirely on logical control systems inside of the control networks to make sensibility.

22:35.280 --> 22:41.360
So if an attacker achieves control of the safety and control system, they can very easily cause a catastrophic explosion.

22:42.360 --> 22:52.520
Another design power plant that would be vulnerable is the CANDU or the PHWR which is that depressurized heavy water which uses deuterium.

22:52.840 --> 22:54.840
And those are used in Canada and India.

22:54.840 --> 23:01.140
They're more stable than the RBMKs, but they're still less stable than the light water reactors we use in the U.S.

23:01.140 --> 23:07.520
Because they use unenriched uranium as fuel, the fission reactivity can increase and have a runaway fission reaction.

23:09.940 --> 23:13.780
And then the last case that we have to talk about is in the U.S.

23:14.080 --> 23:22.540
So while these power plants are much more stable, you can't have this runaway fission reaction where you can have some crazy fission explosion inside the core.

23:22.540 --> 23:24.180
But you can still melt them down.

23:24.200 --> 23:29.900
So Fukushima and Three Mile Island, those were both light water reactors.

23:30.040 --> 23:33.760
And the only reason they melted down was because the cooling stopped.

23:35.760 --> 23:43.240
They use light water as a moderator and so they're designed to make it impossible to create a circumstance where the fission reaction would grow uncontrolled.

23:43.820 --> 23:48.440
And as the conditions of fission increase, reactivity always decreases.

23:48.520 --> 23:52.580
As water pressure goes up, the fission reaction slows down.

23:52.580 --> 23:53.500
That's how they're designed.

23:53.500 --> 23:59.220
They're kind of like something, you know, they're not designed to be, they're designed for stability first and cost later.

24:03.450 --> 24:13.330
So ending the talk, I guess I'll just say that, you know, the talk is kind of based on fear, uncertainty, but, you know, as I studied and looked through this, you know, I found nuclear power is good.

24:13.750 --> 24:16.030
It's clean energy.

24:16.050 --> 24:18.910
Almost one-fifth of all of the power in the U.S.

24:18.910 --> 24:20.230
is created through nuclear.

24:20.230 --> 24:22.390
So, you know, I just have to throw that in there.

24:22.390 --> 24:29.190
And I should also say that this type of attack, you know, using our vulnerabilities could have been used on, you know, our simulator.

24:29.190 --> 24:34.150
I could have chose any industry and we could have a similar kind of crazy disastrous effect.

24:34.310 --> 24:37.450
So it's not necessarily nuclear power that's bad, right?

24:37.450 --> 24:44.410
It's kind of like the vulnerabilities and keeping a reminder on these critical systems to say that basically everything is vulnerable.

24:44.950 --> 24:47.430
All right, so remember to check out our GitHub.

24:47.430 --> 24:49.810
We have all the POCs for these exploits on there.

24:49.810 --> 24:51.970
And you can ask me any questions you want.

24:51.970 --> 24:53.650
I'll be on Twitter, available on there.

24:53.710 --> 24:55.350
And thank you guys very much.
