Hi, welcome to our talk, Powerline Truck Hacking, Two Tools for PLC for Trucks.

00:07.140 --> 00:24.380
We're going to talk to you today for about an hour, you know, who are we, what is PLC, how do you interface with PLC, what are these two tools, PLC for Trucks, GR2497, how can you adapt what you got onto the PLC connection.

00:24.400 --> 00:29.980
We discovered an issue, we're going to discuss that issue and the impacts, and then we'll show you some future work.

00:30.640 --> 00:46.560
So first up about us, I'm Ben Gardner, I'm a researcher with the National Motor Freight Traffic Association, previously done embedded systems development, reverse engineering, I've been an instructor at the Cybertruck Challenge and plan to, when it ever comes back,

00:46.560 --> 00:50.120
I also volunteer at DEF CON and SAE.

00:50.420 --> 00:59.740
Hi, I'm Chris Poore, an electrical engineer who has been hacking things and helping people get away with it for more years than I can count on these blood-stained hands.

01:00.060 --> 01:06.080
I work at Assured Information Security, headquartered in Rome, New York, with locations all over the U.S.

01:06.400 --> 01:17.520
AIS strives to be a driving force for technology and national security and has the combined professional experience that I believe is rivaled only by the space program.

01:17.860 --> 01:20.100
Contact AIS today.

01:20.960 --> 01:22.520
Next slide, please.

01:24.320 --> 01:38.840
It's not just a two-person effort, we're part of a much larger team, a great team that we've been privileged to be a part of, comprised of Dan Salone, Christopher Poore, who you now know, Eric Thayer, all of AIS, and myself from the NMFTA.

01:39.660 --> 01:49.820
Also, this research would not have been possible without the support of the Motor Freight Carrier members of the NMFTA, who sponsored us with access to their facilities and to their equipment, and thank you for that.

01:50.520 --> 01:53.500
First up, what is power line communications?

01:53.600 --> 02:01.900
Generally speaking, any time you're putting data onto lines that are intended for power, you're doing power line communications.

02:01.900 --> 02:06.360
You might know some technologies that fall into this class, such as Green PHY and Home Plug.

02:06.360 --> 02:10.780
There's an entire interoperable family of technologies in IEEE 1901.

02:11.020 --> 02:29.700
The technology is found in automotive, most commonly under SAEJ 1772, which is for plug-in electric vehicle charging, and there was some really interesting work by Baker and Martinovic at USENIX 19, where they showed that they could remotely read traffic between the plug-in electric connection of a vehicle and the charger.

02:29.700 --> 02:34.040
But today, we're not talking about plug-in electric vehicles, we're talking about trucks.

02:34.740 --> 02:41.100
So let's rewind the clock a little bit, maybe a couple decades, and look at what trucks looked like around 1997.

02:41.100 --> 02:53.580
There were anti-lock braking, ABS systems, on trailers and on tractors, and these ABS systems are quite important to prevent rolls and reduce braking distance.

02:53.580 --> 02:55.580
It's really important for safety.

02:55.980 --> 03:02.420
So at the time, there was only a warning on the side of the trailer that showed you if the ABS was malfunctioning.

03:02.440 --> 03:11.220
There are regulators and fleet safety managers that really wanted to have some kind of a dash display that would show the driver if there was a problem with the trailer ABS.

03:11.220 --> 03:16.640
And this, of course, would help make sure that ABS is functioning and everyone would stay safe.

03:18.660 --> 03:21.880
Now let's look at how these trailers and tractors were connected.

03:21.920 --> 03:27.860
So back then, and actually as it is today, trailers and tractors are connected with a J560 connector.

03:27.860 --> 03:34.400
Here you can see that green pigtailed cable plugging into a bulkhead jack there.

03:34.780 --> 03:36.560
And that's a seven-way connector.

03:36.560 --> 03:41.360
You can also see a red and a blue cable behind the bulkhead here.

03:41.360 --> 03:46.660
Those are actually pressurized air, whereas the green cable here, this is electrical.

03:48.520 --> 03:52.880
So back then, they had this tractor-trailer connector.

03:52.880 --> 03:55.100
You can see a breakout here of the J560.

03:55.100 --> 04:04.300
It's got tail lights, right turn, left turn, brake lights, a ground connector, and then this power for ABS and auxiliary power.

04:04.300 --> 04:07.020
So it's a fully populated connector.

04:07.020 --> 04:15.860
There's no room for anything else, but still, regulators and safety managers really wanted to have a way to show the driver when something was failing.

04:15.860 --> 04:25.620
Now an obvious option is to add another connector, but unfortunately, you know, for fleets, the lifetime of trailer equipment is very long and the cost of retrofitting is very high.

04:25.620 --> 04:36.980
So the industry took it upon themselves to design a technology that would let them send this ABS fault data up into the tractor without adding a new connector.

04:36.980 --> 04:50.860
And at the same time, there was a lot of other technologies that people wanted to get data from the trailer into the tractor, and there was things like axle weight, door latch, yaw sensors, and things like that.

04:51.080 --> 04:58.600
So it was hoped that this technology could carry all sorts of information up from the trailer to the tractor, not just the ABS fault info.

04:58.680 --> 05:03.300
Around June 1998, ATATMC actually approved PLC for trucks.

05:03.300 --> 05:06.740
This is the American Trucking Association's Technical Maintenance Council.

05:06.740 --> 05:11.320
They are responsible for making recommended practices in the commercial vehicle space.

05:11.440 --> 05:17.220
And eventually, SAE published J2497 in 2002.

05:17.260 --> 05:25.800
And what they did was add high-frequency signals onto these power lines that run the length of the truck.

05:25.800 --> 05:35.020
So they would couple them onto their either transformer or capacitor, just AC-coupled, and send these high-frequency signals with enough of a voltage that they would propagate.

05:36.180 --> 05:42.000
Now, there was an issue with PLC for trucks that was patent.

05:42.000 --> 05:43.540
It was actually patent incumbent.

05:43.840 --> 05:47.260
And at the time that they started the work on this, they didn't know.

05:47.480 --> 05:54.360
Eventually, it became known, and SAE actually, at one point, just canceled the working group to create J2497.

05:54.840 --> 05:56.800
And eventually, it was resolved.

05:56.800 --> 06:04.580
The technology was patented for a long time, and there were royalties that had to be paid, but the standard did go forward.

06:04.780 --> 06:13.680
Now, if you go to SAA meetings or ATATMC meetings like I do, you've probably seen these patent disclosure and IP statements at the beginning of the meetings.

06:13.680 --> 06:26.440
I've been told that for ATATMC, those passages actually exist because of what happened with PLC for trucks, whereas with SAE, those statements actually predated the PLC for trucks issue.

06:27.060 --> 06:29.780
So it took the industry a while to get it done.

06:29.780 --> 06:30.860
It was quite complicated.

06:30.860 --> 06:34.200
There was a lot of tests that happened over the winter and otherwise.

06:34.240 --> 06:42.460
And as I mentioned, there was other technologies that wanted to get like axle weighing and door sensors and things like that up from the trailer into the tractor.

06:42.460 --> 06:44.520
So they had interoperability tests.

06:45.100 --> 06:50.720
And it ended up being... eventually, it was deployed, but it was quite complicated to get it to that point.

06:50.720 --> 06:57.720
So the news media has been seen to call this technology expensive or complicated.

06:57.720 --> 07:02.140
There's a funny quote right here where someone's saying the most expensive light bulb in history.

07:02.540 --> 07:04.720
So it is funny to look at the technology that way.

07:04.720 --> 07:19.200
But it's also important to recognize that the calculus that the fleets were looking at was whether they would have to retrofit all their trailers, which typically have, you know, 30 year service lifetimes, just to get another light up into the cab.

07:19.200 --> 07:27.720
So creating this technology, even though it seems like it was an expensive light bulb, still, from their point of view, what they wanted was cheaper.

07:27.860 --> 07:31.360
And that's going to be true today as it was back then.

07:31.460 --> 07:33.900
The trailers last for a very long time.

07:33.900 --> 07:36.340
The connectors are still the J560 connector.

07:36.520 --> 07:42.020
And trying to change any of that might prove to be more expensive than anyone would want to spend.

07:42.920 --> 07:49.740
So now you know a lot of the history about J2497 and why it came about and why are we sending these high frequency signals on power lines.

07:49.740 --> 07:52.900
Let's talk more about what it is, how it's put together.

07:53.200 --> 07:59.680
You can think of J2497 like an alternate physical layer for J1708.

07:59.680 --> 08:05.240
And we're not going to go into J17 a lot because there's another talk that will give you lots of details on it.

08:05.240 --> 08:10.340
Suffice it to say that it's a heavy vehicle network that predates J1939.

08:11.660 --> 08:18.260
J2497 has its own arbitration scheme that it employs around J1708.

08:18.260 --> 08:22.580
The PLC for trucks 2497 is always 9600 bauds.

08:22.580 --> 08:28.620
And the way it takes these 1708 signals is it'll actually encode them into spread spectrum chirps.

08:29.180 --> 08:33.440
So another way to think about 2497 is by an analogy.

08:33.740 --> 08:36.680
You can see a couple analogies that I'm making here.

08:36.680 --> 08:41.580
You know J1939 is a lot like J1587.

08:41.880 --> 08:49.180
And J1939 can sit on top of high speed or low speed canned buses, twisted or unshielded.

08:49.620 --> 08:57.120
So similarly can J1587 sit on top of either J2497 or just J1708.

08:57.120 --> 09:01.220
And you'll probably have diagnostics or some other applications on top of those.

09:01.320 --> 09:07.860
Which if you're not an automotive person you can think of it by an analogy to DNS which is built on top of UDP.

09:07.920 --> 09:16.080
And UDP IP can run either like ethernet or 802.11 infrared for example.

09:16.860 --> 09:20.240
So let's talk a little bit more about these spread spectrum chirps.

09:20.240 --> 09:26.220
The specification of J2497 by SAE actually includes a definition of the chirp.

09:26.240 --> 09:33.880
And they have to sweep from 200 to 400 kilohertz, then from 400 to 100 kilohertz, and then from 100 to 2 or 3 kilohertz.

09:33.880 --> 09:38.120
You can see a picture here of a rendering of a couple possible chirps.

09:38.120 --> 09:42.280
Different possibilities result by how you treat these discontinuities here.

09:42.420 --> 09:46.360
The chirps themselves are about 100 microseconds total.

09:46.380 --> 09:50.880
They start and end at value zero so that they can be concatenated.

09:51.260 --> 09:57.500
And when they're transmitted they should be transmitted in amplitude between 2.5 to 7 volts peak-to-peak according to the spec.

09:57.500 --> 10:09.780
Now in practice the transmitters on trailer equipment tend to send them even higher than 7 volts peak-to-peak just to make sure that they'll make it from one end of the tractor trailer to the other.

10:11.420 --> 10:18.060
The chirps are put together into frame encodings that will let them actually send J1708 frames.

10:18.140 --> 10:21.740
And the way the frames are encoded is broken up into a preamble and a body.

10:21.760 --> 10:35.200
The purpose of the preamble is there to realize that alternate arbitration method so that if two PLC devices are trying to talk at the same time there's a way to determine who has the highest priority and which one should back off.

10:35.200 --> 10:36.860
It's very similar to CAN.

10:36.860 --> 10:43.460
It involves that very first byte being sent and the lower byte is the higher priority.

10:43.620 --> 10:47.980
So here you can see two renderings of frames.

10:47.980 --> 10:51.880
The first being OA00, the second being OBFF.

10:51.880 --> 11:01.200
The OA00 frame and the OBFF frame are the ADS fault information that we talked about, the impetus for J2497.

11:01.680 --> 11:07.260
So in the preamble you can see that the messages, the actual chirps have delays in between them.

11:07.260 --> 11:15.540
And this is because the chirps are 100 microseconds but the time for the symbols is 104 microseconds, these little gaps.

11:15.560 --> 11:22.040
In the preamble the presence of the chirp indicates, you know, the logic value.

11:22.040 --> 11:25.620
So logic 0 means chirp present, logic 1 is chirp absent.

11:25.860 --> 11:37.080
But then when you get into the body it's actually 100 microseconds with no gaps and the encoding is actually determined by phase.

11:37.220 --> 11:39.860
So this is phase shift keying in the body.

11:40.140 --> 11:48.540
The phase of logic 0 is arbitrary per device and it's actually given by the phase that's transmitted here in the amplitude shift keying section.

11:49.680 --> 11:55.940
There's a checksum at the end and then there's all these sync bits you can see in orange and in green.

11:56.440 --> 12:04.720
And some of these sizes are variable so there could be one to two initial symbols and there could be zero to four gap symbols.

12:07.240 --> 12:08.800
So why is it like that?

12:08.800 --> 12:14.080
Well J2497 was designed for J1708.

12:14.420 --> 12:23.100
This whole PLC for trucks scheme was actually accomplished by a particular piece of silicon, the Intelon SSC P485.

12:23.300 --> 12:34.220
And this particular chip was designed to take J1708 frames and wrap them around with some extra information and re-encode them into these spread spectrum chirps.

12:34.220 --> 12:43.140
So the Intelon P485 actually adds, you know, these sync bits and adds all the preamble highlighted here in orange.

12:43.140 --> 12:52.580
It will then send, you know, the actual encoded information in chirps as the body which matches exactly what you would see on the J1708 line.

12:52.580 --> 12:57.520
And then it adds these terminators with the gaps and the sync bits.

12:57.760 --> 13:04.040
So the checksum is actually part of J1708 and part of J2497.

13:04.780 --> 13:09.160
And you can see there's a duplication of MIDs.

13:09.260 --> 13:12.200
You can think of MIDs like arbitration IDs in CAN.

13:12.200 --> 13:13.320
It's that first byte.

13:13.320 --> 13:19.780
It determines arbitration on the bus and the data is duplicated twice.

13:20.000 --> 13:28.240
It turns out that this information here in the preamble is used for arbitration of the PLC bus only.

13:28.240 --> 13:36.760
And what gets sent on J1708 is this byte that's put right here, which means that you can send things where those two don't equal each other.

13:36.760 --> 13:39.520
And you can override priority.

13:39.520 --> 13:48.840
So you could send a very low priority MID with an all zero PLC MID and it would margin on top of anyone else that was talking on PLC.

13:50.140 --> 13:52.320
So a little bit about J1587.

13:52.320 --> 13:54.660
This is that next layer above.

13:54.660 --> 13:57.380
You can think of it akin to J1939.

13:58.000 --> 14:02.560
If you look at the J1587 spec, there's a lot of really interesting highlights.

14:02.840 --> 14:07.640
They say that you shouldn't send more than 21 bytes at a time unless the vehicle is stationary.

14:07.640 --> 14:09.400
I wonder what happens if you don't.

14:09.720 --> 14:14.400
There's a factory test MID that should never be sent by any vehicle system.

14:14.460 --> 14:18.580
There are bridging and forwarding schemes defined in the spec.

14:18.580 --> 14:20.920
There's a dynamic address claim.

14:21.220 --> 14:31.640
There are cold and warm reset commands and lots of support for interesting kind of peripherals on commercial vehicles like toll systems and display signage and climate control .

14:31.880 --> 14:44.740
Now for some more details on how to decode J1587 automatically, please see our team's presentation, which should be up today, or look at the pretty J1587 repository.

14:46.140 --> 14:59.700
Even though J1587 defines a lot of interesting things that could be in there, all we've seen in our testing for the most part is the ABS fault lamp on and off messages and manufactured diagnostic messages.

14:59.780 --> 15:15.060
There was a report by the FMCSA that suggested that there should also be axleway yaw sensor and door latch sensor traffic on the PLC bus, but we haven't run into it yet.

15:16.460 --> 15:20.600
So how do you connect to PLC?

15:20.760 --> 15:23.580
There are some great options out there.

15:23.580 --> 15:28.280
The DG Technologies PLC TESCON is very rugged and reliable.

15:28.280 --> 15:29.760
I love mine.

15:30.220 --> 15:40.000
There is also a NEXIC PLC adapter, which has the advantage of being able to go in line on a cable, so you can you can test it in place.

15:40.280 --> 15:45.640
The problem with these sort of classic diagnostic adapters is that they aren't cheap.

15:46.260 --> 15:50.740
You will need them for running manufactured diagnostic tools though.

15:51.100 --> 15:57.500
And also the Intelon P485, I'm told, is becoming harder to source, which is not going to help with the cost of these tools.

15:57.980 --> 16:11.340
Finally, the limitation of these tools is that you can't do anything strange to PLC with these tools, because they just have an Intelon P485 chip in them, and so you can't make arbitrary PLC waveforms.

16:11.340 --> 16:18.140
For example, you can't do different PLC MID from a J1708 MID on the bus.

16:19.220 --> 16:24.860
So how do you interface with J1708 so that you can interface with PLC?

16:25.180 --> 16:34.480
The first one up is another one of those RP-1210 adapters, such as the Digitech DPA4, DPA5, or an EXIC USB link.

16:34.480 --> 16:39.080
And these things are necessary for the manufacturer diagnostics.

16:39.320 --> 16:50.540
An option that I really like, that's really cool, that was presented here at DEF CON 24 is the TruckDuck, which is a beaglebone cape by 6V and Haystack.

16:50.540 --> 16:55.340
There's been some revisions to this board since the DEF CON 24 presentation.

16:55.340 --> 16:59.320
There's the 1.5 EET version and the Mega version.

16:59.520 --> 17:11.400
These beaglebone capes enable communication with both J1939, or any Canon network actually, and J1708 networks through the PiHV networks module that Haystack authored.

17:11.600 --> 17:17.120
And we are going to talk about some ways to use these to write PLC.

17:17.380 --> 17:21.920
So our PLC writing tool, what we wanted was something to be low cost.

17:21.920 --> 17:23.460
We wanted it to be open.

17:23.600 --> 17:26.820
We wanted it to be capable of doing weird things.

17:26.820 --> 17:29.380
We weren't so concerned about arbitration.

17:29.380 --> 17:41.620
The J1708 stack that Haystack put together for the TruckDuck originally didn't have any arbitration, just had frame detect, and it works fairly well on systems that aren't highly loaded.

17:42.920 --> 17:51.500
And we didn't want to worry about getting read in right now, and the reason for that you'll see will be clear later.

17:51.780 --> 18:09.700
So our approach that we elected, mostly because we're biased and we like the TruckDuck, is let's make some small mods to the TruckDuck and push them upstream and try to stick with very small BOM changes, and hopefully 6V can integrate those into the next Mega Mega EET version of the TruckDuck.

18:11.300 --> 18:14.800
So, Bitbanging PWM on the PRU.

18:14.800 --> 18:20.920
Bitbanging is the process of toggling a GPIO in order to create whatever protocol you're after.

18:20.940 --> 18:29.240
GPIOs are general purpose input output pins, of which there are many on the BeagleBOM, and the PRU is a programmable real-time unit on the BeagleBOM.

18:29.240 --> 18:41.300
It runs jitter-free, like deterministic code with no interrupts stopping execution at 200 megahertz, which is plenty for the 400 kilohertz-ish signal of PLC.

18:41.880 --> 18:52.520
And also the PRU was used originally on the TruckDuck for the J1708 stack itself, so there's already a precedent there for using the PRU in this system.

18:53.180 --> 19:09.360
It turns out that the TruckDuck J1708 channel 2 has pretty much been broken since release, which is actually good for us because it lets us reuse, repurpose, one of the PRU cores for the PLC application instead.

19:10.680 --> 19:20.480
And in trying to find pins, we needed to find one that we knew we could bitbang from the PRU, which is a certain class of pins.

19:20.480 --> 19:30.360
But we also wanted to eventually maybe get rid of the PRU, if possible, and use the integrated PWM unit in the BeagleBOM, although that hasn't been done yet.

19:30.360 --> 19:34.980
So trying to find the pin that would work was, you know, one of these fun processes.

19:34.980 --> 19:37.480
I found it best to just do it with markers.

19:37.640 --> 19:40.580
We wanted to make sure that it could be accessed from the PRU.

19:40.580 --> 19:42.500
It could migrate to PWM.

19:42.600 --> 19:46.140
We wanted to make sure it didn't conflict with any other TruckDuck pins.

19:46.720 --> 19:50.320
So for synthesizing PLC, we settled eventually on P928.

19:50.320 --> 19:51.400
We had a backup .

19:51.420 --> 19:59.720
And then we also planned for doing frame detect and PLC read via an ADC, but we haven't implement that.

19:59.720 --> 20:02.200
That's just kind of allocated for later.

20:02.660 --> 20:06.360
So in creating PLC signals, there's two main parts.

20:06.360 --> 20:13.260
You have to synthesize this PLC with PWM, and then you have to couple this signal that you've created onto the PLC network.

20:13.260 --> 20:16.200
So there's these two clouds that we're going to reveal.

20:17.920 --> 20:21.060
I don't often do this, but I thought I would this time.

20:21.060 --> 20:27.380
I would try the dumbest thing first, and my friends will tell you that I'm not very good at doing that, but I did it this time.

20:27.520 --> 20:30.660
The first thing we tried was the dumbest PWM possible.

20:30.660 --> 20:38.400
You just turn it on when the signal that you're trying to realize is above zero, and turn it off when the signal you're trying to realize is below zero.

20:38.500 --> 20:39.800
So you can see that picture here.

20:39.800 --> 20:44.260
The orange waveform is the dumb PWM, and the blue waveform is the true CHIRP.

20:44.340 --> 20:46.180
And it turns out that actually worked.

20:46.180 --> 20:49.220
So we said yay and moved on.

20:49.560 --> 20:51.440
The next part was coupling.

20:51.540 --> 20:57.680
And you can see here in the DGTech PLC test con, the coupling network they created is just gorgeous.

20:58.060 --> 21:08.020
And compared to what we were using, it is amazing because we found out that 100 nanofarad capacitor was enough, and that was our filtering as well.

21:08.020 --> 21:12.760
So the dumbest filtering and the dumbest PWM got us what we needed, and we moved on.

21:13.220 --> 21:16.200
The results were pretty good, actually.

21:16.200 --> 21:26.420
We did run into one issue with undocumented cycle counts for some of the instructions that we we had to use in assembly, but the results were fine.

21:26.420 --> 21:36.900
You can see down here the orange signal is a recording on an oscilloscope of the PLC signal that we synthesized after filtering on a receiver.

21:36.900 --> 21:37.980
Same with the purple.

21:37.980 --> 21:41.000
This is just a larger zoomed out trace.

21:41.260 --> 21:45.340
So this is post-filtering of the signal that we realized.

21:45.340 --> 21:50.560
The signal that we realized is much more like these square waves up here in the tuning edge delays diagram.

21:50.560 --> 22:03.520
And this is just a representation of how we had to tune some of the assembly instructions to make sure that the signal would line up, you know, all the way into the realization like bit 54 of the PLC chirp train that we had to create.

22:03.820 --> 22:05.560
So it worked pretty well.

22:06.940 --> 22:07.860
The code.

22:07.860 --> 22:09.220
You can get this tool.

22:09.220 --> 22:11.220
It's MIT licensed.

22:11.660 --> 22:15.520
It's available on GitHub as of today.

22:15.920 --> 22:19.560
What it does is it adds a new J1708 server.

22:19.560 --> 22:30.380
That's the way that the 1708 was set up on the truck ducks is they receive and send UDP frames and will send or receive those onto J1708.

22:30.380 --> 22:38.020
What we did was create a whole new one that's completely compatible, but what it does is send PLC signals instead.

22:38.140 --> 22:41.360
We also created some command line utilities.

22:41.760 --> 22:52.480
The network, the Pi HV networks that Haystack created has a really nice programming interface for Python, but I just like to have really simple command line tools like dump and send.

22:52.520 --> 22:57.820
So we drafted those and they're compatible with the existing stack as well.

22:58.720 --> 23:09.440
And so to get your truck ducks to connect to PLC, you actually do need to do some PCB changes to your truck duck for now until 6V rolls us into the next revision.

23:10.180 --> 23:19.280
And this led to probably one of my favorite kind of bodge jobs because I love to do rework of PCBs and I also really like it when things have to be MacGyvered.

23:19.420 --> 23:32.000
When we were connecting this up to PLC, we discovered that it would work when there was a really long length of cable in between the power supply of the truck duck and the point where we were coupling to the network.

23:32.000 --> 23:50.420
And if we didn't have that long piece of cable, the truck duck power supply just seemed to attenuate the PLC signals to almost nothing, which led me to this great bodge job right here where I wrapped 40 inches of wire and soldered that down to the board in between the input to the power supply and the connector.

23:50.420 --> 23:53.920
And that actually solved the problem, which is fun.

23:55.360 --> 24:01.260
Okay, so next up we're going to show you how you can use some adapters to connect your truck duck up to the power lines.

24:01.260 --> 24:02.800
There's a lot of different options.

24:02.800 --> 24:07.580
The first is this J560 to DB15 in Deutsch 2-pin.

24:07.980 --> 24:12.720
So these DB15 connectors, you can find them in a lot of different diagnostics adapters.

24:12.720 --> 24:15.140
The DPA4 and the truck duck both have them.

24:15.140 --> 24:19.720
This is a 560 connector here, which is useful to be plugged into the back of your tractor.

24:19.720 --> 24:29.220
You can also plug into the back of your trailer if you have an adapter to connect to the batteries up here on the Deutsch 2-pin, and the whole set is in the DG Tech PLC Tescon.

24:29.560 --> 24:37.640
Next up is these battery clip, the DB15 adapters, and these ones can be found in the Nexic adapter sets on the internet.

24:38.020 --> 24:51.460
There's also these Y adapters for J560, where they give you a Deutsch 9-pin connector in line with two J560 connectors, so these can be used in line with a tractor and trailer that are connected.

24:51.500 --> 25:06.200
You've got to watch out that some of these actually do contain an Intelon P485, and what they're doing is converting PLC to J1708 and routing that to the J1708 pins instead of PLC onto the power pins.

25:07.580 --> 25:13.000
Another one that's useful is one of these inline jack and plug, which is very similar to the previous one.

25:13.000 --> 25:17.620
None of these have the Intelon P485 inside them.

25:18.920 --> 25:28.720
You can also build your own umbilical, so these J560 plugs, you can take them apart by removing the set screw, and you can wire any kind of a pigtail you like.

25:28.720 --> 25:39.160
I like to use these Deutsch 2 pins because they work with the DG Tech sets, and then you can close it all back up and you can have a connector that can be used with a tractor and trailer connected.

25:40.600 --> 25:49.060
So we also created a PLC reading tool, and Chris Poore is going to tell you some more details about that.

25:49.100 --> 25:49.820
Chris?

25:50.120 --> 25:51.220
Thanks, Ben.

25:51.360 --> 26:00.260
One of our goals was to develop a low-cost tool for reading J2497 messages with SDRs and open source software.

26:00.260 --> 26:06.880
We wanted a solution to let just about anybody tap into a line and see messages all for little cost.

26:07.620 --> 26:09.560
Next slide, please.

26:11.960 --> 26:28.880
Again, the J2497 signals primarily consist of a series of 100 microsecond chirps that start at 203 kilohertz, ramp up to 400 kilohertz, quickly drop down to 100 kilohertz, and back to 203 kilohertz.

26:29.100 --> 26:35.940
The 100 to 400 kilohertz frequency range is lower than most SDRs can handle.

26:35.940 --> 26:48.720
For example, the starting frequency of the RTL2832U dongles vary depending on the model, but they can range from 500 kilohertz to around 50 megahertz.

26:50.060 --> 26:51.800
Next slide, please.

26:54.720 --> 26:58.340
To get around this problem, we used up converters.

26:58.540 --> 27:05.860
The Hammett up up converter will take our signal and mix it with an intermediate frequency of 125 megahertz.

27:06.120 --> 27:10.420
I believe the SPIverter uses 120 megahertz.

27:11.020 --> 27:19.020
Once it's near 125 megahertz, we can receive it with radios and begin to condition the signal in software.

27:19.260 --> 27:28.560
We improved the quality of the signal if we didn't tune our radio directly on 125 megahertz, but instead at 126.

27:28.820 --> 27:35.620
This allowed us to use a bandpass filter to get rid of a lot of the DC noise associated with the Hammett up.

27:36.460 --> 27:38.240
Next slide, please.

27:40.240 --> 27:50.060
We achieved most of our success with an RTL and a Hammett up, but there are solutions out there that could be promising that don't use up converters.

27:50.060 --> 27:59.300
We tried the Lime SDR, which starts at 100 kilohertz, but the gain and performance down at those frequencies was too low for us.

27:59.460 --> 28:06.060
You can find schematics online for modifying RTL SDRs to get a lower starting frequency.

28:06.060 --> 28:16.720
They also make some that have a direct receive mode that can tune down to 500 kilohertz, but they say the performance is reduced when operating them there.

28:17.740 --> 28:28.440
The AirSpy HF Plus is supposed to start at 9 kilohertz, but it might not have the bandwidth to support the J2497 chirps.

28:29.520 --> 28:34.580
You might have some luck with oscilloscopes, but then the price starts to go up.

28:34.580 --> 28:39.780
The ADOM2000 is a cheaper option you might want to consider.

28:41.280 --> 28:43.140
Next slide, please.

28:44.420 --> 28:46.260
Back to our setup.

28:46.260 --> 28:54.240
When tapped to the line, we used a coupling adapter to remove the 12-volt DC offset that exists.

28:54.520 --> 28:59.820
This was to be on the safe side and avoid any chance of damaging our upconverter.

29:00.220 --> 29:13.490
Next, the output of the upconverter went to the RTL SDR and was sampled and filtered in GNU Radio, producing a J1708-looking message like you see in the bottom right.

29:14.540 --> 29:23.760
Note how the preamble has visible silent periods, and the body is the continuous section at the end of the message.

29:25.360 --> 29:27.240
Next slide, please.

29:29.240 --> 29:34.440
We developed three methods for demodulating those signals into bits.

29:34.440 --> 29:38.020
One method examines the instantaneous frequency.

29:38.020 --> 29:43.060
The other two rely on correlating the signal with specific sequences.

29:43.100 --> 29:45.740
I'll go over them in the next few slides.

29:46.640 --> 29:48.480
Next slide, please.

29:50.400 --> 29:58.320
Our first attempts took advantage of GNU Radio's quadrature demod block to produce the plot you see in the bottom right.

29:58.580 --> 30:05.960
The sawtooth pattern you see down there represents the frequency over time for chirps in the body of the message.

30:05.960 --> 30:12.240
The circled spikes indicate sudden changes in phase at the start of a new chirp.

30:12.620 --> 30:16.420
This is what we use to distinguish the ones and zeros.

30:17.160 --> 30:25.760
No change in phase means keeps the value of the previous bit, while phase change means flip the bit.

30:25.800 --> 30:38.340
We framed the start and stop of each message based on the amplitude and tried to ignore the preamble sections of each message since the body contains the whole J1708 message anyway.

30:39.700 --> 30:41.400
Next slide, please.

30:43.560 --> 30:53.480
We started developing alternative methods because the previous one did not work well with noise and relied heavily on a consistent signal amplitude.

30:53.480 --> 30:58.440
So to get around that, we correlated the signal with a 203 kilohertz reference.

30:59.600 --> 31:04.800
Now, 203 kilohertz is the precise frequency where each chirp begins.

31:04.920 --> 31:12.960
If there's no phase change, there's a smooth 203 kilohertz signal, which are the higher peaks you see in the output down there.

31:13.680 --> 31:19.820
However, when there's a phase change present, the frequency gets disrupted for a short period of time.

31:19.860 --> 31:24.580
It results in a value close to zero when correlated with the reference.

31:25.320 --> 31:34.860
That's why you kind of see those mini spikes where it's ramping up and down as it approaches the location where 203 kilohertz should be in the chirp.

31:35.820 --> 31:43.740
Likewise, anything outside the message, like the noise, is going to be reduced to a value close to zero.

31:44.200 --> 31:52.220
We use a moving average filter on the correlation output to frame the message and ignore the preamble part of it.

31:52.540 --> 31:54.540
Next slide, please.

31:57.300 --> 32:05.280
Now, for situations where the signal is completely buried in the noise, the previous two methods are not very effective.

32:05.280 --> 32:14.360
Instead, we tried a new method, which begins by correlating the signal with a Python-generated chirp designed to mimic a real one.

32:14.460 --> 32:21.600
The result produces much larger peaks, like you see down there, which helps distinguish it from the noise.

32:21.740 --> 32:31.520
We use this technique to frame the message and reuse the 203 kilohertz reference in the previous method to distinguish the ones and zeros.

32:32.680 --> 32:34.500
Next slide, please.

32:35.800 --> 32:36.420
Next slide, please.

32:36.420 --> 32:40.540
We call it all GRJ2497.

32:40.920 --> 32:47.220
It contains the blocks and flow graphs that will read the traffic and print out messages like what you see on the right.

32:47.540 --> 32:53.060
The values for the MID, data, and checksum are pulled right from the messages.

32:53.820 --> 33:03.940
Additionally, there is an option built into the blocks to send the messages in hex over to a UDP port for other potential tools to use.

33:04.420 --> 33:07.140
Now, back to Ben to continue on.

33:08.120 --> 33:09.000
Thanks, Chris.

33:09.000 --> 33:19.660
So, you've got GENIE radio, and you can now read your PLC signals, but how do you connect your Hammet up or some direct receive receiver onto PLC?

33:20.280 --> 33:24.740
Turns out, once again, just 100 nanofarad capacitor is going to do the trick.

33:24.880 --> 33:33.060
I have used and like to use the 100 volt ones just to be safe, because we don't really want to get battery currents connected to our receivers.

33:33.600 --> 33:38.880
And then you just need a way to connect those PLC wires onto this coupling network.

33:38.880 --> 33:45.980
So, all of those previous adapters that we talked about all apply in this case, but then how do you connect the wires up?

33:45.980 --> 33:51.440
And I think one of the nice solutions we came up with is modifying these Balan19 adapters.

33:51.460 --> 34:12.420
So, you can actually take the transformer off of the board and cut the trace right here at the back, replace that transformer with a surface mount capacitor, bridge the ground here, and then cover it all with solder resist to avoid ever touching 12 volt at back battery currents for trucks.

34:13.440 --> 34:16.780
Another one that's an adapter that works is an antenna.

34:16.780 --> 34:20.580
You actually can read these signals wirelessly.

34:20.580 --> 34:31.680
We experimented with a whole bunch of different antennas, but we found that this form of active antenna, pictured here, works pretty good and is pretty darn cheap.

34:31.680 --> 34:39.700
The power supply that's here is fine, but it works well as well if you connect a 9 volt battery to it instead.

34:39.760 --> 34:49.100
And we believe that there's a lot more options out there because really anything that's made for 2200 meters or low FER is in the right band.

34:49.480 --> 34:58.860
But we stuck with portable options because a lot of low FER and 2200 meter stuff is giant masts and you're not going to move that around with you, but there are loops and whips and mini whips.

34:59.620 --> 35:05.380
But really if you just want to do quick and dirty, these mini whips work really great for the price.

35:05.400 --> 35:17.240
Over here you can actually see, you know, we're receiving a pretty clear PLC signal on top of the background noise using just this mini whip taped to the side of a box next to a truck.

35:18.380 --> 35:22.560
So we're able to read these signals wirelessly, but how far?

35:22.560 --> 35:30.880
In our testing we can reliably receive six feet away from a position next to the gap between the tractor and the trailer.

35:31.180 --> 35:40.900
Now this was using our first version of the GNU radio receiver, the one that does the phase measurements and not the new cool stuff that Chris talked about with correlation.

35:41.060 --> 35:44.000
So we feel pretty confident this can be extended.

35:44.000 --> 35:50.260
We don't know how far and, you more testing, we're going to find out.

35:51.500 --> 35:53.380
Why do we think this works?

35:53.840 --> 36:00.660
It's a bit strange because, you know, these trailers, or maybe the long ones that we were testing on, were 40 feet.

36:01.060 --> 36:12.880
And a half wave, you know, resonator at 40 feet is really only 12 megahertz, which is way, way above the 400 kilohertz top end of PLC for trucks.

36:12.880 --> 36:16.500
So it really shouldn't be a good radiator.

36:16.500 --> 36:20.980
But when we tested it, it certainly is good enough at this point.

36:20.980 --> 36:36.120
And we think that may be a combination of factors, but possibly primarily due to that very large voltage that they transmit, that these devices transmit at, to make sure they can make it across the whole range of the tractor and the trailer.

36:38.220 --> 36:48.840
So yeah, the long wires, the high transmit voltages, I think also contributing this is maybe PLC transmitters are actually left alone to be noisy.

36:48.840 --> 36:56.860
The spec for J2497 allows any conducted noise to be beyond any other restrictions.

36:56.880 --> 37:11.100
And then also FCC's regulations on unintentional radiators actually exempt vehicles, any digital device utilized exclusively in any transportation vehicle from the unintended radiator status.

37:11.100 --> 37:20.880
Now they do still have to, you know, turn off if they're found to be in violation, but it's hard to understand how that could be enforced with a large moving vehicle.

37:21.000 --> 37:31.840
So it seems like maybe these are radiators that are beyond spec and no one's been testing for them because they're exempt or because it's in spec.

37:33.400 --> 37:37.500
There are some impacts to this, but the good news is the impacts aren't very large.

37:37.500 --> 37:39.180
It's really a minor impact.

37:39.340 --> 37:44.980
On trailers, as we mentioned, really the main traffic is just the ABS fault information.

37:45.440 --> 37:56.280
And if that's the only information that's being disclosed by these radiators on a remote read, then you're not really losing confidentiality much.

37:56.420 --> 38:10.820
Now if you are a fleet that's deploying other technologies like, you know, way axles or maybe even your door sensors, any canvassing technology in the trailer, this kind of stuff might be more confidential.

38:10.820 --> 38:12.760
You wouldn't want to have it disclosed.

38:12.960 --> 38:19.820
In terms of the impact in other technologies, other applications of the Intel on P485, we don't really know.

38:20.040 --> 38:26.320
Now one of the reasons we wanted to do this talk is that there are future impacts that really matter.

38:26.320 --> 38:38.100
The ATATMC is working on putting together a new next generation tractor-trailer interface, and one of the propositions include exchanging keys over PLC.

38:38.100 --> 38:53.300
Not that, you know, you can't do key exchange without guarantees of confidentiality, but we just want everyone designing those systems to be aware of the fact that you can't assume that what you exchange over these buses will be confidential.

38:53.620 --> 38:56.540
So it could be a problem if it's not implemented correctly.

38:56.760 --> 39:01.740
And then as we mentioned at the beginning of the presentation, this is not unique to PLC for trucks.

39:01.740 --> 39:11.980
This behavior is present in other powerline technologies, and we encourage you to look at the work of Baker and Martinovic, who showed that this happens in plug-in electric vehicle chargers.

39:12.840 --> 39:14.780
Now what can we do about it?

39:15.320 --> 39:24.080
Presently, there's not a whole lot you could do on existing trailers, because we think that really it's these long wires and the high voltage levels that are contributing to this.

39:24.220 --> 39:28.400
But for the future, there is something you could do.

39:28.680 --> 39:33.760
You also should, if you're a fleet, consider what kind of information is flowing on your trailers.

39:33.760 --> 39:45.760
If you are using airway, if you are using door sensors or canvassing systems, you might want to be aware that that kind of information can't be considered confidential when your trucks are rolling down the road.

39:46.540 --> 40:01.440
You also should be aware if your maintenance departments configure your trailer ECUs to do any streaming of readings, which is possible on several of the manufacturers, where you can configure them to continuously stream wheel speed readings or temperature or voltage readings.

40:01.440 --> 40:04.900
Those wouldn't be considered confidential anymore on those buses.

40:05.040 --> 40:14.700
But for the future, when they're designing the next tractor-trailer interface, I think the main mitigation that needs to be taken into place is reducing those emissions.

40:14.820 --> 40:24.860
And that should be able to be achieved by using PLC on power lines only between the connections where those J560 connectors are.

40:24.860 --> 40:28.280
We recognize that the J560 connector is not going anywhere.

40:28.280 --> 40:32.680
It's going to be too expensive to try to get fleets to move off of it.

40:32.680 --> 40:39.720
So if we only use PLC in between the J560 connectors, that should reduce the radiated emissions.

40:39.740 --> 40:57.760
If we only use it in between those J560 connectors, it also affords designers the opportunity to use lower transmit voltages because the signals don't have to reach across the entire tractor-trailer or multiple, especially multiple trailers in tandem.

40:59.240 --> 41:07.260
So this issue has, throughout the process, has been disclosed to various parties over the past eight months or so.

41:07.260 --> 41:11.220
We've been in contact with trailer equipment manufacturers, all three of the major ones.

41:11.220 --> 41:14.120
We have reached out to all the trailer builders.

41:14.120 --> 41:16.400
Only one of them responded to us.

41:16.660 --> 41:21.200
We have coordinated the disclosure with NMFDA members and our sponsors.

41:21.400 --> 41:29.140
We've also done it with what was previously ICS CERT, who now wants to be called the CISA Vulnerability Disclosure Program.

41:29.600 --> 41:34.400
And they themselves also reached out to the trailer builders that didn't respond to us.

41:35.160 --> 41:49.500
At this time, CISA BDP has assigned CVE-2020-14514, and there is a advisory on this issue of trailer powerline communications to raise awareness forthcoming.

41:49.820 --> 41:54.340
So in terms of future work, it's kind of got two different directions.

41:54.340 --> 42:07.140
I know our AIS friends here do a lot of industrial control systems work, and they're very interested in looking at applications of the same method to various other powerline communication technologies, some of them listed here.

42:07.360 --> 42:18.060
On the transportation side, very much would like to improve those truck tuck features, you know, get some PLC read going, maybe use the PWM unit instead.

42:18.740 --> 42:26.820
I recognize that those DC blocks could be implemented differently, maybe capacitive coupling on one side of the transformer instead of removing the transformer.

42:27.040 --> 42:34.100
Also, the new Balin-19s have really great screw terminals, so you could have a much more rugged connection to the powerline.

42:34.520 --> 42:47.600
We also would like to take Chris's receiver code and figure out just how far the reception can be done reasonably using one of these cheap active antennas, and maybe some of the other more fancy active antennas that we've bought since then.

42:47.920 --> 42:52.180
And then there's also looking at the other places where you find PLC.

42:52.180 --> 43:04.040
We're told that PLC is also used in intramodal, which is where people take containers and put those on top of flat cars or put them on top of trailers on the road as well.

43:04.040 --> 43:07.020
So we'd like to have a look at how PLC integrates in that space.

43:07.840 --> 43:17.880
And there's also this thing, which should be really fun to look at, that someone took a trailer brake controller and of course added Wi-Fi to it, because that's a great idea.

43:18.220 --> 43:23.470
If anyone wants to have fun with a trailer brake controller, check this one out.

43:24.870 --> 43:30.830
But also at the Car Hacking Village, we have two brake controllers hooked up to pressured air.

43:30.830 --> 43:32.650
I'll tell you about that a little more in a minute.

43:33.370 --> 43:38.410
So yeah, in summary, in conclusion, we got you two tools.

43:38.410 --> 43:46.070
There's PLC for TruckDuck, which enables you to write to PLC using 1-bit PLC chirps that we did with bit banging.

43:46.070 --> 43:52.390
You can make an arbitrary waveform, you know, you can have different PLC MIDs than you do for the J1708 payloads.

43:52.390 --> 43:57.090
Everything we put together is compatible with Haystack's PyHV Networks modules.

43:57.470 --> 44:08.890
There's also the ability to read PLC traffic remotely, and this is tracked also internally as ICSVU-227452, and I gave you the CVE earlier.

44:08.950 --> 44:18.470
And the GR-J2497 tool that Chris told you all about is capable of receiving this traffic at a distance of six feet.

44:18.470 --> 44:26.170
And also that GR-2497 tool is itself compatible with the PyHV Networks modules from Haystack.

44:26.170 --> 44:28.290
So this is what I was trying to tell you about.

44:28.330 --> 44:47.610
We actually have a couple trailer brake controllers turned upside down, and we've connected Nerf dart firing cactuses to the exhaust ports on the bottom, and we're running pressurized air on them so that if you can figure out how to do a valve test or do an ECU reset on one of these things,

44:47.610 --> 44:52.050
it should push air through that exhaust port and you should fire those Nerf darts.

44:52.110 --> 44:58.650
And they're connected up on the Virtual Car Hacking Builder system, so there's a Twitch stream and remote logins to the shells.

44:58.990 --> 45:07.050
We do hope that you log in and have a try, and maybe if you get familiar with them, have a try at that Wi-Fi trailer unit.

45:07.050 --> 45:08.970
I know I'd like to someday too.

45:11.410 --> 45:22.170
What we did here was, you know, not the result of just Chris and I's effort, but really the result of a lot of people committing a lot of resources and assistance over the past few months.

45:22.230 --> 45:26.170
And I really want to take an opportunity to put all their names up here and thank them.

45:26.730 --> 45:35.130
Really, this wouldn't be possible without, you know, support of a team and a community, and I feel really lucky to be a part of both.

45:35.210 --> 45:37.370
So thank you very much for your time.

45:37.670 --> 45:45.530
I'll be over in chat with Chris, hopefully answering any questions you have, and I'll see you at the Virtual Car Hacking Village later.

45:45.570 --> 45:46.450