WEBVTT

00:00.620 --> 00:05.920
Hi folks, welcome to Lock Bypass Village and to my talk all about physical reconnaissance.

00:05.920 --> 00:08.480
So this is going to be a fairly low-tech talk.

00:08.480 --> 00:21.380
It's all about how we can use our human senses and our eyes to walk around and tell as much information as we can about a physical facility before we ever actually step inside.

00:21.580 --> 00:27.320
So I gave a different version of this talk at HOPE a few weeks ago.

00:27.420 --> 00:34.900
That one is a little bit more formal on sort of the architectural plans and inferences there.

00:34.900 --> 00:38.360
This one will be taking a more red team perspective.

00:39.020 --> 00:43.480
It's got a lot of new examples that weren't in the other one, as well as a lot of content that was cut.

00:43.480 --> 00:57.280
So I'm going to try to be a little bit faster with this one and take advantage of the more intimate environment that a DEFCON Village gives to make this talk all about the Q&A afterwards and having some interesting discussion.

00:57.320 --> 01:01.060
So to get started with the basic information.

01:01.540 --> 01:04.420
Intelligence follows a cycle.

01:04.420 --> 01:14.680
So we collect information, we analyze it into usable intelligence, and that's going to determine if we need to then collect more to decide ultimately what our course of action is.

01:14.680 --> 01:19.400
So that's the end goal that we need to keep in mind while we're collecting this information.

01:20.860 --> 01:29.700
Reconnaissance is something that we want to do of our physical facility, of course, but we're going to start with the area of influence, both physical and political.

01:29.860 --> 01:34.700
So looking at nearby streets, nearby shops, looking at nearby utilities, etc.

01:34.700 --> 01:40.880
As well as if the organization has multiple facilities, what are those facilities like?

01:40.880 --> 01:49.320
Do they have... well, they usually will have very similar layouts and usages and security situations there.

01:49.320 --> 02:00.380
And we want to observe at a range of times, day and night, week and weekend, and normal operation and during an anomaly to get a sense of how the organization handles that.

02:00.620 --> 02:04.000
We want to look at the people as well as the facility.

02:04.000 --> 02:05.740
So when are they entering?

02:05.740 --> 02:07.660
What the general demographic is?

02:07.660 --> 02:15.020
We can keep track of how many enter and leave at each time to get a sense of the occupancy of the building at a particular time.

02:15.020 --> 02:26.920
We want to look at what entrances and exits they use, as well as any security steps that they take inside, such as keys and credentials, and if they sign in or do anything else on entry.

02:27.780 --> 02:33.920
We can then go up to the main entrance and look at all the information we can get from that.

02:33.920 --> 02:36.260
So this particular picture is very telling.

02:36.340 --> 02:39.300
We can see the fire panel off to the side.

02:39.300 --> 02:45.400
You can get a very good sense of the occupancy and layout of the building from all the different fire zones that are going to exist.

02:45.400 --> 02:49.500
We have our fire safety plan blocks here telling us that this is the main entrance.

02:49.960 --> 02:54.340
We look at all the ways that are access controlled on this building.

02:54.340 --> 03:04.860
So there are a number of keypads, a credential reader, a doorbell, a video doorbell, and a different one used at night apparently.

03:04.920 --> 03:15.860
We can see the elevators through in this lobby, so we know exactly how to get to those, and we can infer that the hallway is going to go perpendicular to that, which makes sense given the layout of this building.

03:16.060 --> 03:26.820
We can notice these magnetic contact sensors there, so that gives us an indication that we're going to see more of those throughout the building, and there might be a networked alarm or intrusion detection system.

03:27.120 --> 03:31.800
So there's a lot that we can tell just by looking at the front doors.

03:31.800 --> 03:47.300
We can zoom in a little bit on the locks, so we can see something like Medeco or Schlage Primus lets us know that they take security a little bit more seriously, as well as an electronic strike plate lets us know that there is an electronic access control system involved.

03:47.300 --> 04:01.020
We can look around back and we might see what's happening in terms of things being disposed of, so if there's a dumpster back that tells you that the area is in flux, there's construction going on or something within it.

04:01.140 --> 04:13.680
You might see something like a specialized disposal bin, so in this case it's a cooking oil bin that tells us that there is a restaurant inside, and they fairly universally look like this, even if they're not so blatantly labeled.

04:13.900 --> 04:24.400
We can find the parking garages, so we know that this one is a full underground garage rather than just a number of vehicles because it starts to slope down.

04:24.400 --> 04:33.360
And we can find the ventilation grates near that and see how deep they actually go based on seeing, in this case, the light coming out from two levels down.

04:33.940 --> 04:49.000
We can look for the loading docks, and so that'll give us a sense of both where the service entrances and service corridors are going to be within the building, as well as what type of material they actually accept at this particular facility.

04:49.220 --> 04:57.520
And then looking around the back, this is a great sign of a site that does not have any alarm system installed on it.

04:58.580 --> 05:05.920
So that starts to give us a sense of what all the entrances around the perimeter of the site are going to look like.

05:05.940 --> 05:12.440
Now we can switch gears a bit and figure out what happens inside of that building envelope.

05:12.440 --> 05:24.000
To do that, we're trying to infer the floor plan of the site, which generally is going to include assignable space, so that's going to be our offices, residences, etc., what people are actually using.

05:24.120 --> 05:28.100
Circulation space, such as halls, stairwells, and elevators.

05:28.100 --> 05:33.500
And building support space, so washrooms, custodial closets, mechanical space, etc.

05:33.500 --> 05:43.700
And by identifying where all of these elements go, we can then help to improve our red team operation with this information before we even begin it.

05:44.500 --> 05:51.140
So with that, we can get the best plan for how to get from A to B, and we can then filter that into a timeline.

05:51.140 --> 06:04.000
So if, say, we need to go faster than the response is going to be coming in after we've set off an alarm or some other trigger for the response to come, we can use this information to determine if that's going to be feasible.

06:04.120 --> 06:14.760
We can figure out where it would make sense to put the cameras and work around that space, as well as we can do a bit of auditory analysis to see where we could be heard and where we can hear other people.

06:14.980 --> 06:21.360
And, of course, if we plan to do any social engineering in the space once we enter it, it really helps to know where we're going.

06:21.840 --> 06:29.220
So you can get floor plans often from the fire safety plan box, if that happens to be available to you.

06:29.580 --> 06:35.000
If not, you can usually do a search online and sometimes get good information there.

06:35.140 --> 06:50.680
So searching for a PDF and a number of keywords that I've outlined here that tend to be found in floor plan files online and not in a whole lot else is going to really help narrow down your search to get floor plans there.

06:50.680 --> 06:56.180
And if it's a public building, there's usually a tenders website that has loads of plans for it.

06:56.240 --> 07:07.120
When we infer floor plans, we're not going to get very detailed diagrams, but we'll get a topology that's good enough for all of these purposes for a red team engagement.

07:07.160 --> 07:11.800
The first thing we'll start with to infer floor plans is the massing of the building.

07:11.800 --> 07:13.840
So what is its overall shape?

07:13.840 --> 07:22.620
We have a primary mass, which is the main shape, anything smaller sticking out of it is called a secondary mass.

07:23.540 --> 07:29.880
This then has surrounding it as a skin is the building envelopes, which envelopes the massing.

07:29.880 --> 07:34.000
It has doors, such as the doors, loading docks, etc.

07:34.000 --> 07:35.440
that we looked at before.

07:35.620 --> 07:39.560
Windows, which we'll use the architectural term of fenestration.

07:39.640 --> 07:50.540
It would have mechanical equipment, so vents and louvres coming out of it, as well as potentially equipment on the roof and external structural members, all of which are clues to the internal layout.

07:50.640 --> 07:57.040
We can get this massing information from Google Maps, often has it for many cities.

07:57.040 --> 08:02.060
Many cities also often have their open data releasing this information.

08:02.060 --> 08:09.320
We can look at satellite views, as well as local government's open data, and of course taking pictures in person.

08:09.740 --> 08:15.040
So from the exterior massing and envelope, how do we determine the floor plan?

08:15.040 --> 08:18.860
So here's an example of a very large complicated facility.

08:18.860 --> 08:28.960
Looking at it from an aerial view, we can start to see that it is very well set out as a linear layout.

08:28.960 --> 08:37.740
So it's branched, but otherwise we can infer, well there's probably going to be a hallway in the center there, with rooms branching off to either side.

08:37.740 --> 08:42.540
The size of those rooms is going to be quantized by the positioning of these windows here.

08:42.560 --> 08:44.720
And so as it turns out, that's exactly what we see.

08:44.720 --> 08:50.660
Hallway in the middle, with rooms quantized by the windows, equal depth on either side.

08:50.660 --> 08:56.800
The stairwells, we can start to guess where they are based on where it makes sense, given fire and egress requirements.

08:57.340 --> 09:09.480
And the entire facility, we see that that holds true as well, with hallways in the middle, and it very closely follows what we could infer from looking at that external massing.

09:10.060 --> 09:14.980
So sometimes we can also get the hall location directly from fenestration or massing.

09:14.980 --> 09:21.060
So in this case, we have both windows and a very thin mass element that tells us that the hall must be in the middle here.

09:21.060 --> 09:23.300
It's usually in the middle, but not always.

09:23.300 --> 09:26.920
So in this case, this bridge tells us that this hall is on the edge.

09:27.460 --> 09:34.160
An interesting case study for these long massings, long thin massings, is prisons.

09:34.200 --> 09:36.980
So cell blocks tend to be laid out that way.

09:37.040 --> 09:40.120
In terms of the inside of them, once you've seen one, you've seen them all.

09:40.120 --> 09:41.900
They all pretty much look like this.

09:41.900 --> 09:54.860
But there's one interesting aside about prison escapes, and that is that every prison needs to have a lavatory in it, and every lavatory needs to have plumbing, and that plumbing has to get out somewhere.

09:55.020 --> 10:09.920
And so that will usually be in a crawlspace, and in older prisons it will often be in a fully-fledged service tunnel that already exists, and that must therefore be connected through a wall from the cells.

10:09.920 --> 10:14.760
So when you hear about people tunneling out of prisons, you think, well that's a very daunting task.

10:14.760 --> 10:24.160
They don't actually have to go very far, just a couple inches of brick or concrete or whatever it might be, to get to the crawlspace where the plumbing gets out.

10:24.800 --> 10:33.120
We can use this, when we're not trying to break out of a prison, to determine where washrooms are in a facility before we ever set foot in it.

10:33.120 --> 10:37.660
So washrooms need plumbing, and multi-story plumbing needs pipe riser shafts.

10:37.660 --> 10:45.360
So you tend to see the washrooms are in the same place on every floor, so that the plumbing can be collinear in that regard.

10:45.520 --> 10:59.980
Pipe riser shafts usually end in mechanical equipment at the top of the building, and so by seeing this mechanical penthouse jutting out on the roof, we can infer that the pipe riser shafts are under it, as likely are the washrooms.

11:00.260 --> 11:08.660
So in this particular example, we have this t-shaped building, and we can infer that there's going to be likely a t-shaped hallway in the middle.

11:08.680 --> 11:22.120
If we did a bit more research, we determined that this was a long-term care home, and so given the dimensions of this building, that would be abnormally large for the suites to extend right the way to the center.

11:22.120 --> 11:35.380
So we might infer that there's going to be two hallways per wing, and support space in the middle, as a building or a facility of this type would need a lot of support space.

11:35.380 --> 11:43.180
We can also see this large vertical window here, indicating some sort of large common room in this area on every floor.

11:43.220 --> 11:45.660
Looking at the floor plan, that is what we find.

11:45.660 --> 11:59.220
So we have this large common room where the window was, as well as suites around the edges, and a loop of hallways in each wing, and then support space in the center, including stairs on each of the three wings.

11:59.220 --> 12:04.040
It makes sense for egress purposes that they would be located there, and central elevators.

12:04.600 --> 12:15.340
High rises are a lot easier to determine what the layout is, because they're relatively small horizontally, and there's a number of things that are often stacked.

12:15.340 --> 12:18.060
So they're the same place, floor to floor to floor.

12:18.100 --> 12:22.000
Obviously elevators, structural columns, and stairwells, that makes sense.

12:22.040 --> 12:29.160
Washrooms need their pipe space behind toilets, so in this case the pipe space is here, but it's nearby to it.

12:29.280 --> 12:39.260
Telecom closets, electrical closets, pipe shafts, mechanical rooms, and vents, all of which have vertical risers that ensure that they tend to be vertically stacked.

12:39.260 --> 12:46.240
What this gives rise to is generally you have a central core that's going to contain all of these building support elements.

12:46.240 --> 12:51.100
So your mechanical room, washrooms, stairs, elevators.

12:51.100 --> 12:58.400
Here we can see in this diagram that pipe space behind the toilets there, and that's the reason that's stacked.

12:58.400 --> 13:09.560
And that also makes sense to use this space that's very far from the windows where people like to occupy for these central core elements, and then let people occupy the outside.

13:09.580 --> 13:21.160
This indicates the column grid here, so this might be partitioned by the final user of the space, and those partitions are generally going to follow the column grid some way or another.

13:21.400 --> 13:30.800
It also makes sense for egress purposes to have the stairwells and elevators in the central core, because it's about equidistant from everything in that floor.

13:31.360 --> 13:41.380
Most high rises have entire floors dedicated to mechanical equipment, and we can locate them by noticing very clear differences in the fenestration.

13:41.380 --> 13:45.140
So instead of windows it's mechanical vent louvres.

13:45.140 --> 13:58.080
If we see the top level of fenestration is well below the roof level, that indicates that there's a mechanical penthouse at the top, and there's also often mechanical basements or partial basements that are going to house that equipment.

13:58.600 --> 14:12.400
So in this particular case we see a number of mechanical penthouses well concealed within the architecture of the building, and in this case we see loads where the fenestration doesn't extend all the way up to the roof, and that indicates that that's what's going on there.

14:12.760 --> 14:25.860
We can also do a bit of math, so we can get the height of the building either by public records, as many of them are, or we can measure it fairly simply with simple trigonometry and angle measurements.

14:26.000 --> 14:38.620
With the height of the building, counting the floors, we can then determine what the average floor height is, and that gives us a sense of both what the occupancy is, what the usage is, as well as where the mechanical equipment will go.

14:38.620 --> 14:51.560
So very very tall floors will likely have false ceilings or false floors, and that does affect our ability to bypass in certain ways, since we know we can get into places through the ceiling or the floor if that exists.

14:52.060 --> 15:02.940
And then shorter ones are then going to have mechanical corridors instead, and they'll tend to be smaller with a central core housing that mechanical equipment.

15:03.280 --> 15:07.940
In terms of high-rise residential, it's not nearly as open as an office floor plan.

15:07.940 --> 15:19.920
It's going to be set up into separate suites, but they're going to follow a central core as well, housing the stairs, elevators, and building support systems.

15:20.280 --> 15:29.100
And it will tend to have a ring-shaped or u-shaped corridor for circulation space to give access to all of those units.

15:29.440 --> 15:41.660
And so in this particular case, we see a slightly abnormally shaped building, but stairs, elevators, support space in the center with a ring-shaped corridor following that general outer perimeter.

15:42.020 --> 15:53.520
In terms of identifying where in the core each things are positioned relative to one another, and in a larger building where these elements are in general, we can sometimes look at the parking garage.

15:53.620 --> 15:58.540
So right away we can see where the structural columns are, and that's going to extend all the way up the building.

15:58.540 --> 16:01.220
We can find where the elevator banks are.

16:01.300 --> 16:11.280
We can find where the telecom riser shafts and pipe riser shafts are by the location of mechanical rooms in the basement.

16:11.280 --> 16:21.480
So in this case, security system room is very likely going to be located very close to the telecom riser shaft.

16:21.760 --> 16:27.580
And that we'll notice is right beside the elevator lobby, which makes sense in the high rise that's going to be above this.

16:27.580 --> 16:37.960
The elevator and the riser shafts and all this other building support space is going to be in the central core, so it will be close to one another in the parking garage.

16:37.960 --> 16:41.580
Of course, we can identify stairs as well.

16:42.160 --> 16:48.720
In older buildings, the stairs tend to be located on the outside of the building, and so we can identify those using a number of tricks.

16:48.720 --> 16:51.980
Sometimes you can just see the stairs very clearly.

16:53.060 --> 16:59.880
Stairs tend to have egress doors at the bottom of them, since they are provided for egress purposes as well.

16:59.920 --> 17:09.960
And when you look at the building at night, if there's one column of windows that's entirely lit up, that is usually a stairwell, because it needs to be lit for egress purposes.

17:10.180 --> 17:13.820
Here's an example of the stairwell being unfenestrated.

17:13.860 --> 17:18.200
It's this secondary mass that runs along the side of the building.

17:18.480 --> 17:25.060
A cue that it's a stairwell... well, one is its general dimensions.

17:25.060 --> 17:30.360
This makes sense for being a stairwell, as well as extends up onto the roof level of the building.

17:30.360 --> 17:36.360
So this is likely a stairwell that goes up and opens up onto the roof, indicating that that is likely what that is.

17:36.360 --> 17:39.600
And then we also have some cell towers on this building.

17:40.940 --> 17:44.480
Stairwells that are fenestrated, we can tell what they are from the fenestration.

17:44.480 --> 17:52.060
So if we see windows that are halfway between the regular floor heights, it's a very good indication that that's a landing on a stairwell.

17:52.060 --> 18:01.200
In this case, we have windows zigzagging up the building, and that's likely going to be following stairs that are zigzagging up, landing to landing.

18:01.200 --> 18:10.280
We also see that this is a secondary mass sticking out of the building, and it sticks up at the top, creating a little exit onto the roof from the top of that stairwell.

18:10.280 --> 18:15.900
And it makes perfect sense that that's located where it is, relative to how these windows are laid out.

18:15.980 --> 18:21.740
In this particular case, we have windows that are not aligned with the rest of the windows in the building.

18:21.800 --> 18:23.140
This is a residential building.

18:23.140 --> 18:28.300
You can tell based on the litness, or how lit the windows are, what that pattern is.

18:28.300 --> 18:33.420
And on this column of everything lit with the exact same intensity, that's got to be a stairwell .

18:34.260 --> 18:43.220
And here's another example of these half-height windows, indicating this is a stairwell terminating in a door at the bottom, and it's a column of lit windows.

18:43.220 --> 18:46.280
So that's very clearly what that is in this case.

18:46.420 --> 18:50.680
Where there's a fire escape, we can tell that there's likely no stairwell near it .

18:50.680 --> 18:53.980
That's about all we can tell, because they are retrofits.

18:54.380 --> 19:01.360
If there's multiple exit doors, and the exit doors are only cued as to where the stairwell is, it might also be to a hallway.

19:01.360 --> 19:05.380
We can tell which one's the primary exit door by looking at some safety features.

19:05.440 --> 19:22.120
So this light up here, to provide illumination to people exiting, as well as we have a parking lot there, so we have some vehicle ballers to protect pedestrians exiting from being rammed into by vehicles parking, indicates that this is the primary door.

19:22.120 --> 19:24.340
And these are likely mechanical doors.

19:24.660 --> 19:29.580
That's helped along by the fact that this vent loop exists there.

19:29.920 --> 19:34.760
So in this case, looking at this building, can we tell if it's an office building or residential?

19:34.760 --> 19:48.420
Based on the pattern of lighting in the windows, we can tell that it is almost certainly an office building, with the lower floors lit, the upper floors likely on timers, and not lit up.

19:49.620 --> 19:55.790
We can tell where the elevators are by looking for the associated machinery that goes with them.

19:56.070 --> 20:09.290
A hydraulic elevator, they tend to be shorter because there's a hydraulic ram that goes as deep into the ground as the elevator is tall, and so they can't go very high.

20:09.290 --> 20:14.350
And as well, they don't tend to show up in very old buildings because they're a newer technology.

20:14.850 --> 20:21.110
Every other type of elevator, and most of them are this second type, which is a traction elevator.

20:21.110 --> 20:24.710
So they're the typical ones that are hanging off of a cable.

20:24.730 --> 20:30.450
And they require a machine room at the top, with some exceptions, but they're rare.

20:30.450 --> 20:36.630
That machine room needs to be sticking out above the top level that the elevator serves.

20:36.630 --> 20:51.290
So if the windows go all the way up to the top level, all the way up to the roof, we can see that if the elevator is going to serve that top level, it's going to need an elevator penthouse extending out, excuse me, onto the roof.

20:51.290 --> 20:52.710
And that's what we see here.

20:52.710 --> 20:58.050
We see three elements, three secondary masses extending onto the roof.

20:58.050 --> 21:08.850
This central one makes sense to be the elevator, both based on the size, if we compare it to these vehicles down here, as well as the positioning relative to the main entrance to this building.

21:08.890 --> 21:15.330
And these secondary masses on the side are likely where the stairwells are coming out, exiting onto the roof.

21:16.630 --> 21:22.690
Another couple examples, we can see an elevator penthouse up here, indicating that's likely where the elevator is.

21:22.690 --> 21:27.050
In a building of this age and height, it's unlikely to be a hydraulic elevator.

21:27.050 --> 21:33.010
And here we can see the elevator directly exiting out the back, and this very likely is a hydraulic elevator.

21:33.630 --> 21:39.010
In this case, we can point out the stairwell very quickly by this column of lit windows.

21:39.010 --> 21:42.390
There's likely going to be one on the other side of the building as well.

21:42.390 --> 21:47.170
And we can infer the rest of the floor plan by noting that there are two balconies per side.

21:47.170 --> 21:52.890
Each balcony is partitioned into two, so eight units per side, or four units per side, eight per floor.

21:52.890 --> 21:55.030
So there's going to be four more on the other side.

21:55.190 --> 22:04.710
We can see this mechanical penthouse only covers part of the building's roof, so the elevator's got to be in the central core, which makes sense for circulation purposes.

22:05.470 --> 22:10.490
And we can tell that this building is likely symmetrical all around.

22:11.230 --> 22:20.730
Utilities are also very helpful for us to determine what a building's used for, what its occupancy is, and where things are within it.

22:20.730 --> 22:21.870
So here's an example.

22:21.870 --> 22:26.170
We can see this particular box coming out is a remote meter reader.

22:26.990 --> 22:34.010
It's for water, so the water meter reader can go and tap an electronic device onto this to read the meter.

22:34.150 --> 22:37.890
And that tells us that this is a mechanical room down here that it goes into.

22:37.890 --> 22:44.090
Here's another example where we have both that box as well as the gas meter leading into that.

22:44.150 --> 22:51.810
And looking into this grate, it's a bit hard to see in this picture, but there is a vent louvre there, further indicating that that is a mechanical room down there.

22:52.010 --> 22:58.530
In this case, we can spot the mech rooms by looking at what we can see, pipes directly in this room.

22:58.530 --> 23:04.230
We can see the fire stand pipe coming out of it, so it tells us something about the size of that mechanical room.

23:04.410 --> 23:08.750
On the second floor, we can tell that there is none here, because we can see in the windows.

23:08.750 --> 23:14.150
And on the third floor, there likely is a mechanical room up here, based on this louvre and the lack of windows.

23:14.470 --> 23:24.350
And of course, there's likely going to be some pipe shaft connecting this first and third floor mechanical room, recessed somewhat into the building, because we know it's on the edge.

23:24.750 --> 23:29.970
We can look at incoming telephone utilities to determine the occupancy of the building.

23:30.150 --> 23:38.450
So a cable coming up from an underground conduit, in this case, we can look at it and see that it, by its diameter, is about a 50 pair copper cable.

23:38.570 --> 23:44.590
So this building had a design maximum of 50 phone lines in the building, and that's going to estimate the occupancy.

23:45.070 --> 23:51.270
We can also look at where the phone lines split up to, if they split up into separate units, to identify what the units are.

23:51.270 --> 23:55.750
So we can see a phone line coming along here, entering the building at this point.

23:55.850 --> 24:00.250
It's a little hard to see, but there is a line swinging up there and entering at this point.

24:00.250 --> 24:04.810
And then there's one along the side here, entering at that point.

24:04.810 --> 24:10.670
So from where these phone lines are entering the building, we can identify where the units are.

24:10.670 --> 24:17.690
That, combined with the fenestration, will give us a very good sense of what the internal partitioning of the walls is going to look like.

24:17.690 --> 24:21.450
Here's an interesting case that gives us a sense of the history of the building.

24:21.450 --> 24:26.830
We see a whole rat's nest of phone lines all going to the same place.

24:26.830 --> 24:35.170
What likely happened there is this is a rental building, and it changed hands many times throughout its life.

24:35.170 --> 24:42.790
And every time it did, a new phone line was installed, and the techs were lazy and just added a new one without removing the old one.

24:42.790 --> 24:45.850
So that's likely why we see this pattern here.

24:45.850 --> 24:48.970
And so that tells us something about what happens within the building.

24:49.270 --> 24:52.490
We can also look at heating, ventilation, and air conditioning.

24:52.650 --> 25:01.890
So in older buildings, these tend to be external units, visible, and we can look at what their capacity is to get a sense of what the internal capacity of the building is.

25:02.090 --> 25:18.570
In newer buildings, we have cooling towers on the roof, and those are going to have a certain capacity, feeding chillers on the inside that are going to then cool a water ethylene glycol mixture down to what it needs to cool the rest of the building and operate the HVAC systems.

25:18.570 --> 25:21.730
We can also look for specialty HVAC equipment.

25:21.730 --> 25:35.530
So if you see something like this, kind of looking like jet engines on the top, that's for creating an extreme negative pressure, generally to drive fume hoods or other chemical exhaust disposal systems.

25:35.790 --> 25:39.110
And so if you see those, that indicates that that's going on in the building.

25:39.110 --> 25:48.430
If you see fans like this, which operate on a similar principle but lower pressure, these are highly associated with cooking spaces.

25:48.490 --> 25:50.470
So here we have an axial fan.

25:50.470 --> 25:53.790
This is common to see over restaurant spaces.

25:53.870 --> 26:02.070
And here we have a centrifugal fan that pulls up from a vent here, indicating that there is likely a restaurant in this location as well.

26:02.530 --> 26:14.070
And in this particular case, we have a large industrial dust collector system, indicating that there's a machine shop or some sort of industrial fabrication system going on in this building.

26:14.150 --> 26:16.290
We can look at the incoming power.

26:16.290 --> 26:25.430
If we have pad mount transformers on the outside, we can look up the capacity of those transformers to figure out what the power requirements are inside that building.

26:25.610 --> 26:35.090
And if it's a volt transformer, we can see if it's a double or a single, giving us a sense again of the capacity to a bit less granularity.

26:35.310 --> 26:38.550
Kind of an interesting aside about how those are actually maintained.

26:38.850 --> 26:48.330
These concrete slabs at the top of them are crane lifted up, and then we can crane lift in and out new transformers to maintain those.

26:48.330 --> 26:50.550
So that's kind of interesting how that works.

26:50.550 --> 27:02.490
These all look similar to this, with an access hatch and a vent, since transformers do need to be vented or cooled in some way, as well as these crane liftable concrete slabs.

27:02.490 --> 27:07.730
So now that you know what these look like, you will start seeing them everywhere in urban settings.

27:08.070 --> 27:18.070
Inside of them we have power coming from the underground duct bank, and it then goes in a separate conduit to the basement of the customer's building.

27:18.210 --> 27:27.850
And so that gives us a sense, based on the positioning of the hydrovolts, where that customer's basement mechanical room is going to be positioned.

27:28.070 --> 27:31.910
If they have a standby generator, they look something like this.

27:31.910 --> 27:44.670
Of course we can't see that from the outside, but that does indicate, if it's present, that it's a highly critical facility that's doing something with high importance, if it doesn't get interrupted.

27:44.830 --> 27:50.090
We can tell the presence of that by looking for these diesel fuel refilling stations.

27:50.130 --> 28:01.930
They look like this on the inside, it's just a pipe that you dump the diesel fuel into, but if you see that, it indicates not only where the diesel standby generator is, but also that one exists in that facility.

28:02.350 --> 28:08.210
Looking at the meters gives you a sense of how many separate units are being metered in that particular site.

28:08.210 --> 28:17.030
So in this case, we have a tack of the gas meters here, and we can count these, and that's exactly how many separate metered units exist within this building.

28:17.430 --> 28:32.750
If we see something like this on the ground, it's a groundwater test well, and so they're going to dig down and essentially leave a pipe, a well, and they can test whenever they need to how deep that groundwater actually is.

28:32.770 --> 28:41.990
That could be used for flood prevention, but you also see this happening anytime there is new construction planned that's going to involve excavation.

28:42.010 --> 28:49.190
So if you see this and it's not in a floodplain, that likely indicates deep construction is being planned.

28:49.190 --> 28:55.970
We can also get a sense from the security features what might be happening inside of a building.

28:55.970 --> 29:06.110
So in this particular case, we have vehicle ram bollards here, fairly beefy, as well as very bright glare lighting.

29:06.110 --> 29:12.530
These vehicle bollards are to protect from vehicle impact attacks, as well as truck-mounted bombs.

29:12.530 --> 29:20.110
If this particular facility has that in its threat model, it gives you a good sense that whatever's going on in there must be fairly serious.

29:20.110 --> 29:35.130
As a bonus here, we have these half-height windows indicating a stairwell, and this lack of fenestration here indicates that there's very likely an elevator shaft there, possibly with a little window vent in the penthouse at the top here.

29:37.670 --> 29:43.350
So looking at the fenestration in this particular case study, we see a weird pattern.

29:43.350 --> 29:53.830
We can tell immediately that there's going to be a basement suite there, so likely from this entrance door there's going to be some stairs up to a fairly tall first floor.

29:53.830 --> 30:05.930
When we have a tall floor, the rooms tend not to be partitioned very small, so it's likely either a large open event space or a number of larger rooms within that.

30:05.930 --> 30:19.210
Anytime we see a strange looking fenestration pattern, like in this case, we can infer that that's certainly because of whatever requirements the inside of this building has for its layout.

30:19.430 --> 30:21.650
Here's a really great example.

30:21.650 --> 30:28.470
So we have this L-shaped building, immediately gives us a sense of the circulation layout within it.

30:28.510 --> 30:36.850
We can see the elevator penthouse here, as well as a chimney stack indicating that the boiler house is going to be below that.

30:36.850 --> 30:56.150
We can see that the boiler house is indeed spanning floors three and four here, and the entire central core supporting this building's utilities is going to be located near there as well by looking at the roof and what exists on the roof.

30:56.150 --> 31:00.410
We can also see this framing here that used to support some heavy HVAC unit.

31:00.410 --> 31:09.790
It's going to be anchored on the columns of the building, and those columns line up with the breaks in the fenestration alongside of this building.

31:09.790 --> 31:17.210
So from this and from the fenestration, we can actually infer the entire structural diagram of this particular building.

31:17.670 --> 31:20.510
So that was sort of a whirlwind tour.

31:20.510 --> 31:31.630
If you're interested in this sort of thing and would like to see a little bit more of the details of how these things are are done, I encourage you to check out my Hope Talk as well.

31:31.830 --> 31:44.730
But this now gives us a great opportunity to have some Q&A, chat about this, chat about some interesting cases that you've seen in your life, and see what else we can infer from these types of tricks.

31:44.750 --> 31:55.390
So I'm hoping that this will make you more situationally aware in your everyday life, look at your built infrastructure differently, and when you're going to an unfamiliar building, know where you're going.

31:55.390 --> 32:05.710
I'd like to extend a huge thank you to Kara and Bobby, Josh, and Eric for their help in preparing this talk, and I'd be happy to take any questions and start the discussion on this.

32:05.710 --> 32:06.850
Thank you very much folks.

