start	end	text
1600	7200	Hello, everyone, and welcome to my talk, Breathless, A Tall Tale of a CPAP Machine.
7200	14220	For those that don't know me, I am Vee, but a little bit more about myself.
14220	19320	I'm an assistant professor in Norway, specifically in digital forensics and incident response.
19320	23880	I'm a very proud cyborg with a long-standing implant since 19.
24200	29080	I did digital forensics and incident response for a long time, still doing it.
29080	30760	I do cyber threat intelligence.
30760	36720	I also like to do some OSINT and find information specifically about medical devices that I'm looking at.
36720	39160	There is a wealth of information out there.
39160	49240	I'm also very passionate about patient rights, specifically being a patient myself, advocating for those that don't have a voice or feel they don't have a voice.
49640	54280	That's currently what I'm doing a lot of in Norway is physician education.
54280	67700	Now, I'm also a proud mom of two little girls, albeit not that little girl, no, that little anymore, but they are absolutely kick-ass, and they will soon be presenting one day similar work that mom does.
68400	71640	Now, what exactly are we going to be talking about today?
71640	81340	Well, the foundation of how I look at medical devices is looking at it by using my scientific process, which is medical device forensics.
81900	85520	This is made up and visualized in a triangle.
85520	90060	A triangle is one of the strongest engineering shapes there is.
90360	94400	I realized that looking at a medical device, I couldn't just look with one lens.
94400	99440	I had to look through multiple lenses to get a holistic picture of what was happening on the device.
99700	108320	Firstly, I wanted to know how it worked mechanically, how it functioned, and that I had to go through a process of debugging.
108320	118860	I had to understand and learn how it works, and that kind of falls into the components of medical device engineering, which every manufacturer will be very familiar with.
118860	127720	Now, also, digital forensic scientific process is one that I've used, and that is kind of, I preserve the information on there.
127720	128580	I examine it.
128580	129440	I analyze it.
129440	131880	I reconstruct a sequence of events.
131880	137200	But I also match that up with, you know, knowing how the device works.
137200	146740	If I know how the device works, and what underlying file systems it has, and how the data is organized, I can anticipate where I will find my forensic evidence.
147400	149760	Now, I also look at the clinical data.
149760	154660	Can I visualize the clinical data as the physician or the doctor would see it?
154660	157160	How does that correlate with the timeline that I had?
157160	159820	How does it correlate with the functioning of the device?
159840	167660	So, kind of bringing it all together to have that whole holistic view of what exactly took place on the device.
171000	180900	Now, I, you know, when I teach this to my students, and when we do the whole medical device forensic class, they're like, but why a CPAP machine?
180900	193140	Now, I'll tell you shortly, but it comes down to the fact that there's about 50 to 70 million people around the world that's been diagnosed with obstructive sleep apnea, or otherwise OSA.
193940	204760	So, it's quite a lot of people that have potentially got a device like a CPAP or a BiPAP that they use every night, every time they go lie down to have a nap.
204760	211420	Now, the sleep economy is 432 million US dollars the last time I looked.
211420	215040	The global market share is 81 billion US dollars.
215120	218800	But those things aside is not the most important thing for me.
218800	223760	My dad has been using his device for a few years now.
223920	228500	And I wanted to know when he initially got the device, how was it functioning?
228500	230080	What was it recording?
230420	232360	You know, how do I know it's working?
232360	236240	How do I trust implicitly in this device?
236340	241400	And he kindly let me look at his device in a non-destructive manner.
241660	253020	So, this whole analysis was done using digital forensic mechanisms that doesn't need to open the device at all.
253920	263720	Now, once you have preserved the evidence or looked at the evidence on the CPAP machine, you'll see that it makes use of a standard EDF file.
263720	268840	Now, EDF files are generally used to record medical signals.
268840	277360	So, they are used in sleep studies largely to see, you know, to record brain signals and how was the patient sleeping?
277360	278660	Was his eyes open?
278660	280100	Was it closed?
280320	283440	Was there any, you know, events where he stopped breathing?
283440	287440	So, this is quite a very standard medical format.
287440	289980	And it's also very well documented.
290040	296120	But the best thing about EDF files is that it's actually in printable US ASCII.
296280	302760	So, you can actually read some of the data with just something like a hex editor, plain and simple.
303180	309860	Now, a signal in an EDF data record is a series of two-byte samples.
310100	318800	These subsequent samples represent integer values of the signals which have been sampled with an equal time interval.
319140	326280	So, these signals are kind of what helps us visualize was the patient breathing?
326400	328520	Was the machine responding?
328640	329800	Was there any events?
329800	335560	But I'll get into the kind of signals and annotations you find on these files a little later.
335840	338380	An EDF file is also super flexible.
338580	341540	It allows for exchange and storage.
341620	345120	It's very simple to use and simple to write to.
345620	353020	Some fun trivia about the EDF file is it was developed at a sleep congress in 1987.
353020	355620	So, it is as old as I am.
355680	361220	EDF+, which was slightly better, was developed in 2002.
361900	364120	Now, let's look at some of the specifications.
364120	365700	And this is not all of them.
365700	368540	This is just the highlight of some of the interesting ones.
368540	377480	Now, the start date and start time fields in the header will only contain characters from 0 to 9 separated by a period value.
377480	385520	So, you could use regex to actually search through the files to find these relevant samples or relevant values.
385560	388740	There's also a local patient identification.
388740	394840	However, this is not always there because this is set up by the technician.
394840	397960	So, it depends on how the machine has been set up.
397960	403260	Now, I know it depends is pretty much a forensic term that we use because there's so many variables.
403260	410200	It's not guaranteed that you'll have all the information that I present today in an EDF file on your machine.
410280	416500	Now, it also includes the birth date of the patient in a day, day, month, month, year, year format.
416660	419720	This machine was a South African machine.
419720	425260	So, quite possibly this could change depending on your region the machine was bought from.
425260	427760	I'm thinking specifically in the US.
429900	439840	So, these are kinds of very important because this is how we correlate evidence and timelines is using these specific values.
440100	450120	Now, if we look at this, this is an ASCII translation table to give you an idea of how you can actually parse out the header file.
451280	454240	As you can see, there is a start date.
454240	457020	There's a local recording identification.
457760	459700	This table is freely available.
459700	461660	There are resources to it.
461660	478660	But this was just to give you an idea of actually, you know, how looking into data-driven analytics processes, because this is how I came to this information, allowed me to actually look at the files in the raw format and identify quite quickly if there was any,
478660	485180	you know, sequences that were out according to the local recording times because those are supposed to flow.
485180	490260	Now, if a patient didn't use it for one evening, there would be a gap in the date and time.
492480	499000	Now, I looked at two devices because my dad had one device and then ultimately upgraded.
499140	502200	This is not a reflection on the manufacturer at all.
502360	505200	This, it wasn't looking at vulnerabilities.
505200	508040	I was simply looking at can I do forensics on the device?
508040	510260	Can I actually learn from the data?
510260	517140	Can I marry the engineering with the forensics with the clinical side of things?
517140	519080	Now, more about the device.
519080	525900	The ResMed AirSense 10 machine collects quite a lot of statistics and quite a lot of interesting statistics.
525900	530140	It has an AHI index, pressure and leak usage.
530140	541780	Now, the machine allows a patient to sleep more comfortably because it keeps the airways open, positive airway, by actually high pressure air that goes in.
541800	552060	Now, how they monitor whether a patient is using the device is that they actually record specific statistics that get sent away to the doctor.
552060	561880	So, this device has the capabilities to actually send data out and be connected to a network.
562320	564980	It depends on the geographical location.
564980	570460	In South Africa, this is not very much used where the data doesn't get sent to the doctor.
571520	578080	Now, let's look a little bit at the different kind of signals or the different kinds of things that the CPAP machine records.
578080	581920	Now, the first one we're going to look at is AHI signals.
581920	590900	Now, these are recordings of the number of hypopneas or times you stopped breathing has been recorded.
590900	594380	And these are done by an hour-by-hour basis.
594460	603580	Now, the AHI index is one of those that I quite frequently used in the CPAP scenarios to actually determine the overall sleeping health of the patient.
603580	612880	This is a severity rating of how bad the patient's sleep is, how many events they have, how well treatment is working.
612880	620400	It's also an indication whether there is more clinical need for an adjustment to the machine.
620600	644820	Now, the AHI signals has got forensic clinical value because it indicates the overall sleep health of the person, specifically looking at hour-by-hour basis, how many times the patient stopped breathing, overall using the mathematical equation to determine what the index is about how bad your overall sleep health is.
644820	653440	So this is quite an important signal that I looked at to determine whether or not my dad was actually improving or not improving.
654000	658360	Now, the CPAP pressure setting, this is a fixed pressure setting.
658360	667100	Now, it's also very important to know that there is a maximum pressure that a human being can take.
667100	671080	So there are recommendations for the devices not to go over that.
671080	679740	Now, if you go look at the machine itself, you will see that it's a very patient-specific setting.
679740	685240	There will be a high and there will be a low setting, meaning that they may be different from day to night.
685240	691200	You might have a higher requirement for pressure in the night versus during the day.
691280	697020	Now, this is recorded in a file that's called a .brp file.
697400	701500	This is also known as the high-resolution graph data.
701500	710100	And this value will change as the device is used because it basically is alternated.
712100	715480	Now, for example, if we look at this, this is from my dad.
715480	718680	And yes, I have permission to show you this data.
719040	721000	Also, this is very old data.
721000	722220	It's not his latest one.
722220	727800	If we looked at these two kind of things, we have the statistics on the left and we have the device settings.
727800	733280	Now, the minimum pressure rate is 6.4 versus the maximum that is 14.
733280	739220	Now, that is well within the range of what a human being can safely use.
740000	745240	However, if you look at on the left-hand side, you see the values fluctuate a little bit.
745240	748560	And this is how the device is responding to his different needs.
748600	752260	So, the one value, the statistics, is how the device has been used.
752260	754180	And then you have the device settings.
754580	756660	Now, why does this match to us in forensics?
756660	762720	Well, if we know what the clinical setting is supposed to be, we can correlate that the device is set to that.
762800	767780	Any deviation from that would need to be further investigated as to why it was changed.
767780	774360	Also, with the statistics, you can correlate that the device is responding within those parameters and not exceeding them.
774400	790520	If you look at the FDA's database about where a patient complains specifically about medical devices, where physicians also can complain, there were other manufacturers that had problems with pressure being far exceeding what was safe.
790520	792980	And patients had adverse reactions.
792980	796320	So, adverse reactions do occur in these devices.
796700	799620	I'm not aware of any in this specific one.
799620	808060	And I could correlate with my dad's data that he was receiving what was programmed and what was appropriate for his needs.
808060	811080	Now, it also has a leak.
811080	814220	Now, everyone will say, well, it's not supposed to be leaking.
814220	820640	But there is some normal leak, you know, air leak expected with these devices.
820640	825880	Now, the ResMed AirSense 10 has a built-in leak differential within the mask.
825880	834140	It also has the ability to actually indicate whether, you know, the mask is properly used or not.
834180	840700	Now, if this value is exceedingly high, there could be two potential issues.
840700	847680	One could be there is a device fault, that there is such a big leak, or it's just an improper mask fitting.
847820	856680	And these are things that you would investigate if a patient came to you and said, well, you know, I'm not getting adequate treatment.
856680	873120	If you looked at a CPAP leak and you see that it's far exceeding what the manufacturer states in their manuals, you would firstly look into how the mask is fitted, and see if the patient's got it right, if the mask needs to be replaced, or whether it's actually a device fault.
873360	881320	Now, as I said, some leak is normal, and every device on the market has their own threshold, and this is contained in their manuals.
881780	890340	Now, this is also used to calculate by, you know, how long the mask was worn, and normally measured in litres per minute.
890560	894480	And this you will also find in the clinical representation a little bit later.
896040	910420	Now, this is also how they use it, they use measurements for compliance purposes, to send it away to the physician to see whether or not the device is used adequately, properly, and correctly.
910840	916580	So this is kind of how they monitor patients' usage of the device.
917040	931860	Now, once we have done understanding around what the device records, what the data is like, I like to look at the partitioning schema and file system, because this is actually where it becomes known to us, this is where we recognize things a little bit more.
932080	939940	A little secret that I've learned is medical devices are nothing weirder than what we are used to in digital forensics and incident response.
939940	949700	They are slightly different, but at a fundamental level, there are similarities between systems we know versus medical devices.
949700	956720	Now, this specific one had a master boot record with a single partition on, which was a FAB32.
957520	962320	There was no volume label set for this specific one, but there was a serial number.
962980	975140	The recordings of the data was in Big Endian, so I can already anticipate kind of what kind of hardware it is, because there's specific hardware that works with, and systems that work with Big Endian.
975240	985800	But it's important to know that, you know, the Big Endian is what is used, because that, when it comes to your date and time formats, it depends on how you will read the hexadecimal values.
985980	987720	Little Endian versus Big Endian.
987720	992560	So this was kind of an important thing, because I didn't fully anticipate that it would be Big Endian.
992560	996560	I kind of thought it would be little, but this was quite a surprise for me.
997320	1005140	And now, if we looked at the folder structure, and like I said, this was a non-destructive way of looking at the data recorded on the SD card of the machine.
1005240	1016380	I haven't opened the machine yet, because at that time, it was under warranty, and it was actively used by my dad, so I didn't really want to go mess with things to a large extent.
1016380	1028680	Now, if we looked at, logically, at the SD card after we've imaged and mounted it, to understand what was on it, there was some files and folders, and these are kind of uniform across the ResMed range.
1028680	1040720	Now we have a data log folder, we have an identification.crc, identification.tgt, journal.dat, sdr.crc, sdr.edf.
1040720	1046260	Now, the crc values are that of its associated file.
1046480	1048540	I'm not going to go into all of them.
1048540	1050700	I'm only going to highlight the most important.
1050700	1059520	If you want to know more about the in-depth analysis of each of these components, feel free to reach out to me, and we can have a discussion about it.
1059520	1061380	But I'm a little bit short on time.
1061500	1070480	Now, the data log folder contains high-resolution graph data records, and it's information about the airflow of the device.
1070540	1076100	It also contains annotations and notes, whether or not events have taken place.
1076100	1082660	Now, if an event has taken place, it is recorded in a .eve file, which is the events file.
1082720	1093420	Now, this is an annotation that is used to determine whether the patient suffered any attacks like hypopnea, apnea, obstructive apnea, or central apnea.
1093420	1101080	So it kind of is about, you know, is there any adverse events that was noted and that the machine responded to.
1101080	1107520	Each session is split across four .edf files, and these are different files that contain different annotations.
1107520	1114320	The file names are generated by date, type, and type of recording, and then followed by the .edf extension.
1114600	1122160	So you would have .eve files, you will have .bpd files, because they contain different information.
1122160	1127320	There is also a CRC checksum generated for each of the files.
1128140	1139740	Now, this is an example of a high-resolution graph data, and it tells us more about the airflow, as well as events that have taken place.
1139940	1146800	But this doesn't tell us much in terms of just looking at it like this, but I will show you how to visualize it better.
1147320	1150320	Now, str.edf was another one that was very interesting.
1150320	1153640	This is the file that contains the values for the HI index.
1154980	1162240	And as I said earlier, this is a very important thing, because we want to know what the overall sleep health of a patient potentially is.
1162360	1166240	And the way that we know that is by looking at the str.edf file.
1166300	1174520	It's updated at the end of every session, but most records only contain one entry per day, because it's at the end of the session.
1174520	1180760	And theoretically, most patients generally use this during the night, because they're not sleeping during the day.
1181300	1185600	This file can also be used as a summary of the recorded sessions for the day.
1185920	1195320	But it's important to know that there will only be mostly one, and it would be an overall HI index of how the patient is at the end of the sessions.
1196140	1202660	Now, another interesting thing that I wanted to look at is, well, what happens if I actually factory reset the device?
1202660	1206120	What happens, you know, how's the data retained?
1206820	1217560	And the SN10 has multiple processes that it goes through to erase all data, and it has some data retention policies or things in place.
1217560	1221660	It kind of looks like it is just a high level format.
1221660	1233680	So what I did was actually, you know, backup my dad's data, factory reset the device, and then look at whether or not I can actually retain, you know, recover some data.
1233820	1240700	But the overall data retention rules are your BRP data is continuously erased every seven days.
1240700	1245620	And this is important in digital forensics to understand what data is erased.
1245620	1253740	And when I say erased, I mean that it is made unallocated so that the file system can overwrite that value.
1253740	1258840	So there is still the potential to recover files if it hasn't been overwritten yet.
1258840	1265380	So the quicker you do a forensic acquisition of a potential device, the better off you are to recover data.
1265380	1269880	Obviously, the longer time goes past, the more difficult it gets.
1269880	1273620	Now, PLD data is continuously deleted every 30 minutes.
1273620	1278040	So this will be much harder to recover versus that of seven days.
1278080	1282160	Now, SAD and EVE files are retained for 365 days.
1282160	1284280	Now, these are your events and airflow files.
1284280	1289620	So these are, in my opinion, the most important ones to look at.
1289620	1292240	And luckily for us, they don't get deleted.
1292460	1298740	Obviously, this is on an SD card, so it runs the risk of actually filling up.
1298740	1301760	But it takes quite long because these files are quite small.
1302660	1310820	Now, when I looked at the manual for the Essence 10 device about how to factory reset it, it is simply a quick format.
1310820	1313000	It formats the SD card.
1314320	1321480	And if you've done digital forensics, you know that there's a large chance on FAT32 that you'll be able to recover the files.
1323080	1330540	When examining the unallocated space for one thing, you can actually look for EDA file signatures, which you can see below.
1330540	1333360	And you can go search and recover for those files.
1333460	1351640	Now, because this is a FAT32 file system, it allows for us to use normal digital forensic techniques we would have used to retrain a FAT or to go look for files that have been marked with hexadecimal 0XE5, which is how directory entries are marked as deleted.
1351840	1355260	Now, those can be reversed if the data is intact.
1355260	1361300	So you can do data recovery on these devices just because of the file system that's on there.
1361300	1371560	And I think this is one of the things people don't expect with medical devices is that it actually follows rules of data storage of file systems we know.
1372600	1376240	Now, I did note that there were some inconsistencies.
1376240	1391240	The deleted file directory entries, when I examined them to determine the information that could be, you know, distinguished or I could understand, there were some inconsistencies with regards to dates and times which were recorded in the directory entries.
1391240	1397060	This was anticipated just because of it being a medical device.
1397100	1400460	Sometimes it throws in a loop or it throws in a surprise.
1400460	1413880	Now, the creation date for the deleted files is no longer reflected, but it is rather overwritten with a set value of hexadecimal 0X00, 0X32.
1414020	1419520	And this is recorded at the offset hexadecimal 0X10 in the directory entry.
1419620	1421560	However, the timestamp remains intact.
1421560	1423340	So the creation date is overwritten.
1423340	1435840	Now, the last access date in the offset hexadecimal 0X12 is overwritten with the value 0X00, 0X31.
1436520	1439360	But the timestamp remains intact.
1439360	1441620	And so it carries on.
1442680	1449040	It seems that the dates are rather overwritten versus the timestamps that are still in the files.
1449040	1458560	Now, the creation date and time corresponds to the file name, as the file name is made up of year, year, month, month, date, date, and so forth.
1458560	1473200	So you can still identify the creation time, but it becomes a little bit harder with the last date access, which could be a very crucial piece of information to see whether something has been tampered with or not.
1473360	1477640	However, just looking at the file name, you can find the creation date and time again.
1478000	1487560	I am not entirely sure yet why it overrides the information in directory entries, or whether this is an accidental override, or whether this is intentional.
1488340	1495140	This could be potentially an undocumented side effect of the methods that are used to delete data from the SD card.
1495960	1503140	I am still investigating this and trying to examine different hypotheses as to why this is happening.
1503160	1509540	The modified date and times are noted and accurate based upon the last time the machine recorded and accessed that file during therapy.
1509540	1520000	So it's very hard at this point to understand why that has happened, but it is something that I'm currently testing further.
1520200	1526400	Now, EDF files you can look with Hex Editor, or you can actually use some Python.
1526460	1536720	Now, the way that I found this was quite accidental because I found EDF files in big, large data analytic studies, specifically about sleep studies.
1536720	1540540	And I found that they were using Python to actually parse this information.
1540540	1545760	So I thought, well, surely I can use this to look at the EDF files of my dad.
1546420	1556420	And one of the libraries that I used was pyedflib, which allowed me to actually read or actually write to files if I wanted to.
1557420	1564420	And it gave me information about who the patient was, the start date, time of the file, and what signal labels was recorded.
1564420	1567840	So not quite a lot in terms of what I wanted to have.
1567840	1574120	So I further researched and I found EDF-RD, which was the one that we used in my course.
1574520	1581900	And this is something that was designed in 2000, that was specifically to read and write EDF files.
1581980	1585100	It's a very low-level library and it's very easy to use.
1585100	1587480	I mean, after all, I used it and so did others.
1587480	1590880	It's very easy to extract the information.
1590880	1600940	I could get the patient name, the start date, start time, and number of data records that was recorded, which allowed me to anticipate, you know, what kind of files was on the SD card.
1601080	1603800	These are some examples just of the code.
1603800	1612360	As you can see, it's very simple and it allowed me to get quick and dirty information about the EDF files recorded on the ResNet machine.
1613020	1616720	But I wanted to find out how do I visualize the technical aspect.
1616720	1620840	I've now looked at the engineering side of things, how the device functions.
1620840	1624700	I have looked at what's contained in the EDF files.
1624700	1628560	I've looked at the file system, but I wanted to visualize the sleep data.
1629120	1643120	Now, in comes OSCQR, which is an open source CPAP program that is used by this, you know, the community that does have CPAP.
1643120	1646960	And it's quite amazing what you find in the information that they're willing to share.
1647800	1652700	Now, OSCQR stands for the Open Source CPAP Analysis Reporting.
1652760	1667660	Now, I had a forensic image, a DD file containing all the information from the SD card, but how this device functions is that you need to plug in the SD card and then it will automatically import the files.
1668000	1686000	So how I got around this little thing is I actually mounted the forensic image as a removable drive and then import the information into OSCQR to determine whether what I found in the raw data and the digital forensic side of things was actually matching up visually with what was happening.
1686660	1693000	Now, if you look at this on the left-hand side, we see an AHI index of 0.26.
1693000	1697560	We see more about the kind of events that were suffered.
1697560	1700580	We see statistics and we see the machine settings.
1700920	1704240	Now, on the right-hand side, these are visualized in a graph .
1704340	1709940	But at this point, you know, it doesn't make quite a lot of sense, but you can actually correlate data.
1709940	1716380	Now, if we look at where the orange square is, you will see that there was an event that was noted.
1716800	1721040	The flow rate was increased for the device.
1721040	1728400	The pressure was constant, but the leak rate was quite high, which could indicate the therapy was applied, as well as the flow limit.
1728400	1740480	So you can actually correlate across whether the device, whether one, events taken place, whether the machine appropriately responded, and whether the patient received treatment.
1740560	1752640	Now, you'll also see that if we look at this, there was an obstructive event where my dad struggled to breathe.
1752640	1759260	And we can see that it's recorded and that he received constant treatment or positive airway.
1759260	1761840	So you can correlate the information.
1761840	1764900	Now, we see that there was large leaks here that was happening.
1764900	1767220	This is not due to machine failure.
1767220	1769820	This was due to him not having his mask on correctly.
1769820	1774880	But knowing that this was occurring, we were actually able to get the mask fitted properly.
1774880	1778000	We have some obstructive events that have taken place.
1778160	1783560	So this quite tells you when something has happened, whether the machine has responded appropriately.
1784220	1787320	And you can correlate these things around the device.
1787320	1790500	So it's a very nice way of visualizing the information.
1790500	1802420	And as a patient, understanding your treatment and understanding whether or not you are improving and taking, you know, and being clinically supported as you should.
1802680	1807340	Now, the statistics on the device contains quite a lot of information.
1807340	1812740	It contains machine information when it was last used, when it was first used.
1813060	1819740	And this is kind of important information to just understand the overall view of the device.
1819900	1821840	Now, future work.
1821900	1827000	My dad has obtained a secondhand CPAP machine for me because he's amazing and awesome.
1827000	1829220	He doesn't think that I'm completely weird.
1829360	1838030	I will be taking apart this machine to forensically acquire the machine as well and then correlate the final piece of the puzzle.
1838250	1844490	My first attempt was just to look at the data from a non-destructive way.
1844950	1851290	So stay tuned for future talks on looking at the device versus just the information that's recorded.
1851530	1855830	A special thanks specifically to the Biohack Village, my home away from home.
1855830	1858150	I am missing you all dearly this year.
1858150	1861730	Nina, looking at you for all the support you've given me through the years.
1861730	1862970	You've been amazing.
1862970	1872570	Jay Radcliffe that actually piqued my interest into CPAP machines by giving me a image a few years ago that has led me down this path to want to look at this more.
1872570	1878250	And then my dad for not, you know, thinking that I'm completely crazy and weird and supporting the research.
1878250	1879510	I hope you enjoyed it.
1879510	1889310	If you have any questions, feel free to reach out to me and I will happily have a conversation with you and point you in the right direction.
1889370	1895710	If you want to know more about the resources, you can look here and find them.
1895710	1898790	Thank you again for having me and I hope you enjoyed it.