[00:00.000 --> 00:04.160] So hello, everyone. How are you doing? I'm Nidal. I'm the head of the Data Duplication [00:04.160 --> 00:11.260] Village. We have a repeat speaker here. This is Andy Klein. He is the individual who has [00:11.260 --> 00:17.020] come to us several times, three, four times now, to the Data Duplication Village and spoken [00:17.020 --> 00:23.880] for us. He works for a company that does hundreds, if not thousands, if not tens of thousands [00:23.880 --> 00:31.400] of hard drives. More. Every year. And he's come to talk to us about those hard drives, [00:31.400 --> 00:35.400] their reliability, and how they compare with SSDs and a number of different things. But [00:35.400 --> 00:39.520] instead of giving away everything, I'm going to introduce you to Andy Klein. Andy, thank [00:39.520 --> 00:40.520] you for joining us. [00:41.560 --> 00:47.120] Hey, thank you, Scott. I appreciate it. And like you said, for the last few years, I've [00:47.120 --> 00:51.420] been coming out and talking to the folks at the Data Duplication Village about hard drives [00:51.420 --> 00:56.240] and SSDs and so on and so forth. And let me give you a little idea of what we'll talk [00:56.240 --> 01:00.760] about today. And by the way, any time you have a question, please just stick your hand [01:00.760 --> 01:06.220] up in the air and we can get that out of the way. I'm old. You don't need to know that. [01:07.200 --> 01:12.200] We're going to talk a little bit about the data we collect. It's about hard drives. It's [01:12.200 --> 01:17.360] hard drive failure data, hard drive capabilities, and so on and so forth. We'll talk about failure [01:17.360 --> 01:22.660] rates. I'm going to do SSDs for a little bit. They're kind of popular these days I've [01:22.660 --> 01:28.960] heard. And then I have a bunch of other oddball statistics that I'll just throw in there about [01:28.960 --> 01:33.280] hard drives and things that we found out. And then finally, we're going to put all of [01:33.280 --> 01:39.320] this in action. In other words, how we make use of it moving forward. So, kind of fun [01:39.320 --> 01:40.520] to do. [01:41.140 --> 01:47.560] All right. So, a little bit about the environment. All right? Right now, we're currently monitoring [01:47.560 --> 01:54.060] about 250,000 or so hard drives. So, that's not a bad day at the office, right? About [01:54.060 --> 02:00.180] three exabytes of data that we're dealing with. We've been doing this for the last ten [02:00.180 --> 02:07.300] years. Hence the title, right? So, we started back in 2013. We record the data every day. [02:07.300 --> 02:13.000] You'll see that in just a second. And then we can analyze the data and figure out what [02:13.000 --> 02:19.000] kinds of patterns we might see in the information that were there. So, I forgot to bring my [02:19.000 --> 02:26.540] hammer. We have a bunch of different data centers there. The fun one is the data center [02:26.540 --> 02:33.640] on a boat. Excuse me. A barge. So, this is actually kind of cool. I just brought this [02:33.640 --> 02:38.740] along. It's got nothing to do with the fact except it's full of hard drives. But it's [02:38.740 --> 02:45.920] actually water cooled. There's no freezers or anything like that in there. It sits on the [02:45.920 --> 02:52.840] San Joaquin River in Stockton, California, which is kind of nice. Saves us a bunch of [02:52.840 --> 03:00.720] electricity. Doesn't kill fish. And so on and so forth. Okay? Which is all cool. But this [03:00.720 --> 03:07.880] is where things need to go in general. Right? Data centers like the guys we are doing use a [03:07.880 --> 03:14.220] lot of electricity. Do a lot of interesting things to the environment. This is our first [03:14.220 --> 03:19.040] step. So, it's one of the nice things that we're doing around here. All right. So, let's get to [03:19.040 --> 03:24.620] the data. Okay? Again, I said we've been storing it since 2013. We use a package called [03:24.620 --> 03:30.820] smart run tools. It just takes something called smart stats off of every single drive. Every [03:30.820 --> 03:37.500] hard drive, every SSD out there for the last 20 some 30 some odd years produces these [03:37.500 --> 03:44.780] statistics. And then this package will read that. Okay? What we did is those statistics and [03:44.780 --> 03:51.460] I'll show you some of them a little bit later. All right? Every day we snap the statistics off [03:51.460 --> 03:56.760] of every single drive. And that's what we've been keeping. All right? And it gives us the [03:56.760 --> 04:03.080] ability to track a drive and its behavior. So, for example, one of the statistics is [04:03.080 --> 04:10.320] temperature. I can monitor the temperature of every single drive I have. All 250,000 of them. [04:10.320 --> 04:15.800] Okay? I can tell when something's getting interesting inside there. I can monitor the media [04:16.420 --> 04:22.580] inside of every single drive. And I can understand that we're having trouble failing in writing in [04:22.700 --> 04:27.400] a certain area. So, we can do all of that kind of stuff. And that's what we've been doing. All [04:27.400 --> 04:34.600] right? The data is open source. So, you can go and play with this if you choose to. All right? [04:34.600 --> 04:41.500] It's a bit to download. But you're more than welcome to do so. And people do. Interestingly [04:41.500 --> 04:49.040] enough, the drive manufacturers do. And you'll see why in a minute. So, what does it look like [04:49.040 --> 04:55.600] just to be just to kind of get everybody on the same page? You can see I lost my colors. Oh, [04:55.600 --> 05:03.300] my goodness. It's horrible. The so, here's the data. It's just laid out, right? Row, data with [05:03.300 --> 05:09.020] columns. It's no big deal. Nothing spectacular. You can see smart one normalized. You get a [05:09.020 --> 05:16.100] normalized value and a raw value for every smart statistic out there. There are potentially 255 [05:16.100 --> 05:23.860] of them. Pairs like that. No more any given drive doesn't use any more than 40. And that's a pretty [05:23.860 --> 05:29.860] high number. And we'll look at some of them a little bit later. Like smart one is a read error [05:29.860 --> 05:36.280] rate. Smart five is reallocated sectors. They'll start to be interesting. Smart nine is power on [05:36.280 --> 05:42.420] hours. How much that drive has been running. All those kinds of things. Right? Now, the data [05:42.420 --> 05:48.060] there, you can see there's a failure in one of the columns. That's how the data marks a failure. [05:48.380 --> 05:55.340] That drive failed that day. It was it's gone. It won't be there tomorrow. All right? And that's [05:55.340 --> 06:03.900] how we know. We know that that particular drive, that particular model, SD800, so on and so forth, [06:03.900 --> 06:12.460] okay, failed that day. Now, each row for each day is what we call a drive day. And that's [06:12.460 --> 06:17.440] important to understand when we start to do aggregation and we start to figure out failure [06:17.440 --> 06:26.780] rates. All right? Speaking of failure, so what is a failure? All right? Now, most people would say [06:26.780 --> 06:33.560] my drive failed when it stops running. That's a failure, right? We have two states. We have [06:33.560 --> 06:39.120] what we call a reactive failure, which is exactly that. I can't talk to it. It doesn't give me data [06:39.120 --> 06:45.580] back. It's broke. Okay? For all of that. And then we have something called a proactive failure. [06:45.580 --> 06:52.120] Okay? We're monitoring these on a regular basis. You might get what's called ATA errors coming at [06:52.120 --> 06:59.600] you, which are electrical type errors. You might fail an FS check, a file system check. Or combine [06:59.600 --> 07:04.620] that with the smart data that we were just talking about. All those various statistics. And you go, [07:04.620 --> 07:10.960] no, that drive is on its way to failure. And I think I need to get it out of there. Now, why [07:10.960 --> 07:17.820] would we do that? Why would we care? Right? The reason we care, one of the primary reasons is if [07:17.820 --> 07:25.360] I can take a drive out before it rolls over and dies, I can clone it. Cloning works really well [07:25.360 --> 07:32.660] right about here. You get about a 95% success rate to clone a drive. And why is cloning important? [07:32.940 --> 07:38.860] Because you know how long it takes to rebuild the drive when you put it in? Like a rate array. And [07:38.860 --> 07:47.240] you pull one out. Not bad with a 1 terabyte drive. Maybe it's a day or two. Gets kind of, okay. With [07:47.340 --> 07:53.180] a 4 terabyte drive, because that certainly gets to be 4 or 5 days or 6 days. We're dealing with [07:53.180 --> 08:01.500] 116 terabyte drives right now. And that can take weeks. So, I don't want weeks. I can clone it in [08:01.640 --> 08:06.700] a day and a half and have it back in the array and running and keep up what's called durability [08:06.700 --> 08:13.980] on the whole system. Right? So, you can start to see the data we collect and the decisions we make. [08:13.980 --> 08:20.200] But either one of those will produce that little one in that column and that drive is gone. Okay? [08:22.140 --> 08:28.900] Now, how do we compute this thing called annualized failure rate? Which is what we publish. [08:28.900 --> 08:35.020] You'll see that number as we go through the thing. Right? We take a group of drives. A cohort of [08:35.020 --> 08:41.360] drives. In this case, all of the models that were active as of 6-30-2023. Okay? All of the [08:41.360 --> 08:48.600] different drive models. And we give it a period. Q2. And then we just obtain the numbers for those [08:48.600 --> 08:56.040] things and we do some math. Drive days. Number of drives running each day over that period. [08:56.100 --> 09:00.660] Failures. How many failures. These are real numbers, by the way. I'm not making these up. [09:00.760 --> 09:07.920] Okay? And at the end of Q3, Q2, excuse me, we had 240,000 drives we were looking at. Right? [09:08.400 --> 09:12.080] And then we do a little math there and we come up with a number and it says, [09:12.080 --> 09:17.720] that's our annualized failure rate. And then we publish that number and we hand people the data. [09:18.600 --> 09:26.020] Right? And say, here. Now, sometimes people say, hey, why don't you use drive count? Because [09:26.020 --> 09:31.820] that's what I would do. I had ten drives, one failed. I have a ten percent failure rate. We [09:31.820 --> 09:37.760] can't do that. Because that makes the assumption that you had ten drives over the entire period [09:37.760 --> 09:44.140] you were looking at. We don't. We're constantly adding drives in and taking drives out. You know? [09:44.140 --> 09:51.860] So, we have to use drive days instead of drive count. I tried publishing the reports one time [09:51.860 --> 09:58.020] without drive count and everybody yelled at me because they really want that number. Okay? But [09:58.020 --> 10:06.780] it's irrelevant. So, what do we do with the data? We put it in some quarterly reports. Some of you [10:06.780 --> 10:11.620] may have seen it. We do it for hard drives. We do it for SSDs, which we'll talk about in just a [10:11.620 --> 10:17.660] minute. We give you the data for the most recent quarter. We give you the data on an annual basis [10:17.660 --> 10:22.020] and a lifetime basis for all of the different drives that are out there. It's kind of useful. [10:22.020 --> 10:26.620] If you want to go there, go to the blog, type search for drive stats, you'll get effectively [10:26.620 --> 10:33.360] eight years' worth of reports. And you can see what the heck this is all about. It's free. We [10:33.360 --> 10:38.720] don't charge you. We don't track you or any of that silliness. If you would like to get a [10:38.720 --> 10:44.340] newsletter, you can join in. Sorry, that's what the marketing people do. But that's about it. [10:44.760 --> 10:52.320] Okay? So, a report kind of looks like this. Okay? It's a table. We write some fancy words around [10:52.320 --> 10:57.500] it and make it look pretty. I pulled out a couple of things in here. Because as people start to [10:57.500 --> 11:03.200] look at this, I want you to understand what you're looking at. Right? One of them, the first one [11:03.200 --> 11:10.680] there, the HGST one, right? It's got a 13% failure rate. And people go, that's terrible. I would [11:10.680 --> 11:17.960] never want one of them. Okay? And that's not a good conclusion. Because there's only a total of [11:17.960 --> 11:25.400] 8,000 drive days. Right? That's not a lot over a quarter. You really want 50,000, 60, 70,000, [11:25.400 --> 11:32.480] start to get a number that feels good. All right? So, not much there. I highlighted the Seagate [11:32.480 --> 11:39.900] one. Because it's our old timer. And the data duplication village guys have been using the 6 [11:39.900 --> 11:46.980] terabyte drives for the last few years. Or asking you to bring them in. As the case may be. And [11:46.980 --> 11:55.120] that happens to be look how old that is. 98 months. That's not bad. Right? 8 times 12, 96. [11:55.120 --> 12:04.040] Little over 8 years on average in a data center. Okay? Being beaten every day. All right? A good [12:04.040 --> 12:09.260] little drive. It does bring up one point. And I want to point this out. If you ever do look at [12:09.260 --> 12:18.840] these reports, okay? And you see that model number, that ST6000DX000, right? And you can go, [12:18.840 --> 12:24.400] wow, that sounds pretty good. I'm going to go get me one of them. Right? And you go to the store [12:24.400 --> 12:35.940] and it's a ST6000DX005. They're not the same. Okay? Different model. Okay? They may look the [12:35.940 --> 12:41.700] same. They may have the same specs and everything like that. There's a reason that Seagate and all [12:41.700 --> 12:49.180] of the other manufacturers change the model numbers. And they don't tell us. So, if it's [12:49.180 --> 12:55.480] on there and it's a certain number, you like it, great. Okay? But if you can't find it, [12:55.480 --> 13:04.220] the next model over, okay? Your call on that. In other words, the models don't transfer. It [13:04.220 --> 13:10.480] doesn't go from one to the other. So, in the most recent quarter, we had a total of 31 different [13:10.480 --> 13:15.740] models. These are the ones we're using in our data center. These are active. They are drives [13:15.740 --> 13:23.500] that we are storing customer data on. Okay? So, they are in use. And they're treated all the [13:23.500 --> 13:28.700] same. They're all given air conditioning every day. Right? There's a guy who comes out and [13:28.700 --> 13:36.560] dusts every once in a while. No. Another chart you'll see is what's called lifetime. That [13:36.560 --> 13:42.060] previous one was quarterly. This is lifetime. This is a whole lot more accurate for the whole [13:42.060 --> 13:50.060] drive, for the picture of the whole drive, right? A couple of fun ones there. There's that HGST one. [13:50.320 --> 13:54.880] There you can begin to see this thing called a confidence interval, all the way in that last [13:54.880 --> 14:01.220] two columns there. That is the it's a statistical thing. You don't have to care what it is. All you [14:01.220 --> 14:10.320] have to care about is the delta between those two numbers, .5 or less. Maybe .6 or less. Okay? If it [14:10.320 --> 14:17.280] is, you got a pretty solid number in that AFR column, annualized failure rate column. If it's [14:17.280 --> 14:25.200] not, you don't. And it's that simple. So, the first one, the HGST, that difference is ten. [14:25.440 --> 14:34.360] Not .5, ten. Okay? Which means that AFR 656 is, eh. Okay? We just did some math. That's all. All [14:34.360 --> 14:39.960] we did. Okay? Statistically, that's not a valid number. We publish it, but it's not. The one right [14:39.960 --> 14:49.720] below it, .2. Okay. All right. That failure rate of .59% for that drive is pretty solid. All right? [14:49.720 --> 14:56.000] You can probably look at that and go, that fails at less than 1%. That's a cool drive. I like that. [14:56.040 --> 15:02.680] Right? You can look at the one, the last one there for Seagate. Oh, my goodness, look, no drive [15:02.680 --> 15:10.020] failures. That's great. Yeah, it's great. But, again, a pretty wide number there. So, it doesn't [15:10.020 --> 15:15.040] have enough history. And I tell you this because people look at these numbers all the time and then [15:15.040 --> 15:21.740] they go, you know, I want you to, you know, they complain. And the confidence interval is there for [15:21.920 --> 15:28.240] a purpose. So, take a look at it. Use it. Make it part of it. Now, one of the things that people [15:28.240 --> 15:36.280] talk about is, you know, what can I use this for? All right? The data itself. Okay? That we [15:36.280 --> 15:42.100] published. And I always tell them, it's entirely up to you, obviously, what you want to do with it. [15:42.180 --> 15:49.540] But there's nothing out there like this. The only other data you get is manufacturer's data. And [15:49.540 --> 15:56.420] every manufacturer I've ever seen either has an annualized failure rate of .9 or 1%, depending [15:56.420 --> 16:04.340] on how they feel. Okay? And it's never higher and it's never lower. All right? So, this is a [16:04.340 --> 16:09.320] little bit helpful in trying to talk to you. Now, you can make all of the arguments about, hey, [16:09.320 --> 16:15.020] different environment, all of that kind of cool stuff, right? Right? We do treat these things [16:15.020 --> 16:21.120] nice. We don't put them in an external case and stuff them under the bed. Okay? You know, so, [16:21.120 --> 16:28.740] but they do a lot of work for us. All right. Just to make your life a little easier, I put together [16:28.980 --> 16:36.660] a list of things that we call, you know, gold medal winners. And I'm going to actually start [16:36.660 --> 16:42.020] from the bottom of the list just to kind of show you some things here. The bottom three, the ones [16:42.020 --> 16:49.300] with the little three there are friends. Those drives are those are really great numbers. Okay? [16:49.740 --> 17:06.080] Excuse me. Those are really great numbers. But you can't buy them. You can't buy them new. You [17:06.080 --> 17:14.780] can buy rehabs. Rehabs all bets are off. Okay? So, and if somebody's trying to sell you one of [17:14.780 --> 17:22.000] those as new, they must have had them in a warehouse somewhere for the last eight years. You [17:22.000 --> 17:29.060] go up a little bit to the 12 terabyte drives. You can kind of see the numbers there. You can still [17:29.060 --> 17:45.170] buy all of those. But two of them are from HGSTs. The two from HGST are actually rebranded as [17:45.170 --> 17:54.710] Western Digital now. Okay? Western Digital bought a chunk of the HGST business five or six years [17:54.710 --> 18:03.810] ago. Seven or eight years ago. The top ones are all pretty legit. Fourteens and sixteens. I [18:03.810 --> 18:10.530] haven't seen that very top one available for sale in the US. So, maybe you want to go down to the [18:10.530 --> 18:17.510] second one. Okay? But, those are solid drives. They've been performing for us. They got more [18:17.510 --> 18:24.630] than two million drive days. So, they've been working. Um, you know, make sure, whatever [18:24.630 --> 18:30.570] choice, use the data however you want to help make decisions. Alright. Uh, a little bit about [18:30.570 --> 18:41.930] SSDs. So, last year I talked about this with, um, at the group. And, um, we, we had this question [18:41.930 --> 18:50.790] about SSDs and reliability versus HDDs. Right? Everybody said SSDs are much better. But [18:50.790 --> 18:58.270] nobody had any proof. Right? So, so we went and we started to take a look and see what we could [18:58.270 --> 19:05.830] do. But you always want to compare apples to apples. So, the only place we had SSDs were as boot [19:05.830 --> 19:14.950] drives. But we also had HDDs, hard drives, as boot drives. Right? So, we wanted to compare them. Now, [19:14.950 --> 19:20.950] boot drives you might think of as turn on the machine, spins about 30 seconds or whatever, and then [19:20.950 --> 19:26.090] it just sits there and does nothing. Ours don't do that. Ours are actually used for daily, for [19:26.090 --> 19:32.670] temporary storage. Um, the drive stacks actually get downloaded onto them and then get offloaded [19:32.670 --> 19:39.730] about once a week. Um, so these are drives that are working. Right? Um, they, they are reading and [19:39.730 --> 19:44.250] writing on a regular basis and deleting files and all of that kind of stuff. And you can see the [19:44.250 --> 19:52.530] counts aren't spectacular, um, but it's about 4,000 drives we did the analysis with. And last [19:52.530 --> 19:59.970] year I presented this chart. And I asked the question, I says, well, what are we gonna do? So, [19:59.970 --> 20:05.130] what we had done here, let me give you a little background, is we tracked the failure rates over [20:05.130 --> 20:13.550] time for the red, which was the hard drives, remember, the boot drives, um, and the SSDs in the [20:13.550 --> 20:19.070] first year they were in existence, the second year, and so on and so forth, as they aged. Okay? And [20:19.070 --> 20:23.050] we got to year four and we didn't have any more data for the SSDs because they had only been [20:23.050 --> 20:27.630] around about four years. So we said, well, what do you think's gonna happen? Because they [20:27.630 --> 20:33.810] kinda tracked pretty closely together there, right? We said, do you think it's gonna go up? Follow [20:33.810 --> 20:40.050] it up? Do you think it's gonna be, meh, in the middle? Or maybe it's gonna level out. Right? And [20:40.050 --> 20:44.830] the answer, you know, and we had people guessing and everything like that. And the actual [20:44.830 --> 20:53.670] answer is, they were all wrong, they went down. Okay? Um, the SSDs, and I will tell you, I'm [20:53.670 --> 21:01.870] getting ready to do the next report, uh, for SSDs, and the number continues to be that low. So, [21:02.610 --> 21:09.370] SSDs do in fact seem to be more reliable than HDDs. Which everybody said it would, but at [21:09.370 --> 21:14.650] least we have a little bit of math now, uh, in a practical environment, um, to, to put it [21:14.650 --> 21:20.130] to rest. Now, at some point, we'll put SSDs in the data center, we'll start using them, we'll [21:20.130 --> 21:24.230] compare them and all of that, but that's, right now it doesn't make it sense from a cost [21:24.230 --> 21:31.470] perspective to do that. So, SSD is pretty solid though. Yeah. Okay? So you can see the numbers [21:31.470 --> 21:39.330] right there. The other thing we looked at over the last few months is the smart stats, remember? [21:39.330 --> 21:45.690] The statistics we catch for each, we capture for each of the hard drives. Tell us things like [21:45.690 --> 21:52.390] media, temperature, and so on. Well, SSDs do the same thing. They report that data. Okay? And [21:52.390 --> 21:58.170] we can record it. And nobody was making any sense of that. That we could find out. People [21:58.170 --> 22:06.570] tried, um, and we tried to say, well, what are we gonna do? So, we took three of them. Three [22:06.570 --> 22:13.670] SSD models. Alright? And I listed them there. Uh, the Seagate, the WDC one, and the Crucial one. [22:13.670 --> 22:20.270] They were all 250 gig SSD drives. Okay? So they're all identical from that perspective. Um, and we [22:20.910 --> 22:27.190] analyzed the smart stats. And we said, what the heck do we have? Alright? What are we looking at when [22:27.190 --> 22:31.790] we look at it? Is it any good? Okay? They've been doing, the hard drives have been using smart [22:31.790 --> 22:40.390] stats for, oh, I don't know, you know, 25 years. Um, is, uh, you know, so what about SSDs? And we [22:40.390 --> 22:47.490] found some things that were common between all three models. Right? Power on hours. Yay. Uh, [22:47.490 --> 22:54.810] power cycle count on and off. Uh, temperature. That was good. And then a couple of them. SDD, [22:54.810 --> 23:01.050] SSD wear leveling and unexpected power loss. Those were the only five attributes that were [23:01.050 --> 23:11.170] common between those three SSDs. And so for example, the Seagate has 20 pairs. Only five are [23:11.170 --> 23:21.950] common with the other one. That means 15 are unique to the Seagate. Why? Okay? So we tried to [23:21.950 --> 23:28.010] figure out what were interesting ones. Um, and I want to talk about a few of those today just so [23:28.010 --> 23:35.430] you can see. It's a little bit of a wild west right now as it relates to SSDs and smart stats. [23:36.290 --> 23:42.970] Right? Here's a good one. Lifetime percentage. Now, and most of us would say, oh, that's, I get [23:42.970 --> 23:50.570] that. Okay? That means how long do I expect this thing to live? Where is it perhaps in its life [23:50.570 --> 23:57.990] cycle? Okay? That's a really, really cool thing. And they calculate that. All three of the [23:58.010 --> 24:07.810] vendors, the three different vendors, use a different smart stat. Okay? The WDC one and the [24:07.810 --> 24:14.090] Seagate both basically compute it the same way. Okay? Something called program erase cycles, [24:14.090 --> 24:20.770] available blocks, math. Okay? And then they get a number, an SSD, a number that starts at a [24:20.770 --> 24:27.090] hundred and comes down. Okay? So a hundred is new, new, new, new. Ninety-nine, still pretty [24:27.090 --> 24:35.650] new. Ninety, really good. Okay? In the case of the Western Digital one, when it gets to zero, [24:35.650 --> 24:42.090] you got to, it's over. It's past its life percentage time. You really should yank that drive. In [24:42.090 --> 24:48.370] the case of the Seagate, it's ten. That's their threshold value. And the number zero, that [24:48.370 --> 24:56.530] means the drive's in read-only mode. Right? Now, okay, so that's, it's close enough. The folks [24:56.530 --> 25:02.950] at Crucial decided that they weren't going to count down. They were going to count up. Okay? [25:03.130 --> 25:10.570] Okay? So it's lifetime used. So the number comes up as zero when you buy it, and it goes up as [25:10.570 --> 25:19.230] you use it. All right? So I don't know. You know? So one of the things that points out, by the [25:19.230 --> 25:25.150] way, is that tools like smart CTL, which is what we use to do this, right, now have to pull [25:25.150 --> 25:31.930] out, I have to pull out three sets of numbers and do my analysis if I want to compare things. And [25:31.930 --> 25:36.310] then I have to remember, in the case of the Crucial one, to flip. Right? And that's kind of cool. [25:37.210 --> 25:41.990] The other thing we saw is that all three vendors, and they're not the only ones, it's not, [25:41.990 --> 25:47.950] Micron does the same thing, Dell seems to do the same thing, all, all of the different vendors [25:47.950 --> 25:54.870] seem to have their own tool that you're going to get. Now, by the way, that's really cool if you [25:54.870 --> 25:59.710] buy a Crucial drive and a Crucial SSD, you got three or four of them, you really like it, it's a [25:59.710 --> 26:04.490] great brand, you go, and you use that tool to do your analysis and see the health of that drive [26:05.010 --> 26:11.250] and excellent, right? Right? But when you're in a business that has actually more than one type [26:11.250 --> 26:16.950] of SSD, it starts to get to be a pain. And when you're in a business that has 20 different types [26:16.950 --> 26:24.450] of SSDs, it's a pain in the neck. So one of these days I hope they kind of get their act together [26:24.870 --> 26:31.170] and maybe make these a little more consistent. Another one, some interesting ones that I found [26:31.170 --> 26:39.070] as I was digging through these, right? WDC has something called drive life protection status. [26:39.890 --> 26:46.910] Right? And this is amazing because it, it has this thing like, it's like a trajectory, it says, [26:46.910 --> 26:53.410] okay, this implies that they have, they can calculate their drive life, and then it implies [26:53.410 --> 26:59.570] that there's some curve that they've come up with, okay, and embedded into that so that they [26:59.570 --> 27:08.630] can do this projection. Okay? But nowhere have I been able to find what that curve is. So is it [27:08.630 --> 27:15.370] tied to, for example, the warranty period? Or is it, whatever, right? Is it tied to load? So you [27:15.370 --> 27:19.690] are, you, they have a curve like this, and if you're using your SSD too much, it could be above [27:19.690 --> 27:31.010] it, but, okay, what's too much? Alright? Endurance remaining, okay, that's kind of, kind of fun. [27:32.170 --> 27:38.830] The, with SSDs and stuff like that, it's a twisted way of looking at the protection status, [27:38.830 --> 27:47.750] but there's no curve. The last one is actually really cool. Okay? This is, the folks at Crucial [27:47.750 --> 27:53.250] have this built in. It's a little thing called RAIN, which is kind of like RAID, except on their [27:53.250 --> 28:03.310] SSD. Okay? And what they do is they hash out your data, and they store the parity off. And so if you [28:03.310 --> 28:11.230] as a customer suddenly start to use your SSD, and the data can't be found, okay, in a normal read, [28:11.230 --> 28:18.290] they can use the hash to recover it, and that's all completely invisible to you. Right? Really, [28:18.290 --> 28:23.750] really awesome. Okay? They didn't say whether that parity was actually part of that 250 [28:23.750 --> 28:32.150] gigabits, or it's added and you don't see it. Okay? But the overheads for something like that, [28:32.150 --> 28:38.910] it's got to be 10, 15% of storage to pull it off. But it's a really cool feature because, again, [28:38.910 --> 28:44.190] as a user, you wouldn't even know it. Okay? They go read something, they couldn't read it, [28:44.190 --> 28:54.430] they use the hash and recover it. Man. Really enjoyed that one. One of the questions that came [28:54.430 --> 29:01.350] up while I was doing a bunch of research was this one. How long can you store an SSD without [29:01.350 --> 29:07.330] power? You take it, put it in the closet. Right? We all do this. We do it with hard drives. We [29:07.330 --> 29:12.630] expect them to last forever. Okay? We expect to pull that hard drive out after five years. Plug [29:12.630 --> 29:19.090] it in and spin that puppy right out. And, I don't know, sometimes that doesn't happen. Sometimes [29:19.090 --> 29:26.810] you got to get out the hammer and hit the top. Sometimes you got to get a new hard drive. So, [29:26.810 --> 29:33.430] SSDs. Okay? The number, the number's been all over the place, but I'll just say the current [29:33.430 --> 29:45.490] thinking is about a year. Okay? Is the maximum. Now, that seems to be tied to how long the drive, [29:45.490 --> 29:51.610] busy the drive is. How tired it is. How much it's been used before. Crucial actually documents [29:51.610 --> 29:58.970] that. Okay? And has a little number. So, all the way over on the, that side. I get my left and [29:58.970 --> 30:06.070] right screwed up all the time. You can see, if you look at smart value 202 and it's a zero, once [30:06.070 --> 30:14.070] again, they like to count down and count up. Zero, the maximum storage period, a year. Okay? And [30:14.070 --> 30:21.330] as that number goes up, they continue to reduce it. So, if that number's 50, six months. If it's [30:21.330 --> 30:30.310] 100, a month and you're stretching it. Okay? The other two vendors, okay, don't have similar [30:30.310 --> 30:35.450] attributes that they use for the same kind of thing, but I can't find any documentation which [30:35.450 --> 30:43.890] says that's the way it works. All right? So, I can't trust it, but it seems to be that those two [30:43.890 --> 30:51.090] pieces are built that way for it. So, if you're thinking of taking a hard, an SSD and putting it [30:51.090 --> 30:56.490] in archive for a little bit of time, you may want to take a look at that number for the SSD and [30:56.490 --> 31:02.630] see how long you think you're going to put it there for. If it's been used a lot, you may not be [31:02.630 --> 31:11.710] able to get away with putting it in there for a year. Right? All right. So, a little bit more [31:11.710 --> 31:20.990] about, oops, okay. No more about SSDs. Apparently it's, hey, computer's pissed off. Um, so we'll [31:20.990 --> 31:27.970] get back to hard drives. Just some fun stuff about hard drives. A few months ago, there was an [31:27.970 --> 31:34.030] article published by Secure Data Recovery. It's another company in the business. And they came up [31:34.030 --> 31:39.570] with this number which said, hey, we looked at 2007 failed drives and the average age of a failed [31:39.570 --> 31:46.730] drive was two years and ten months. And that, I looked at that and said, oh my, that seems really [31:46.730 --> 31:55.390] low. I was thinking, it's got to be higher than that, right? So, I took more data. Okay? And over [31:55.390 --> 32:00.250] the years, we've had about 17,000 or so failures and I said, what's the average age they failed [32:00.250 --> 32:08.230] at? And it came up to two years and six months. And I went, you just look at something and it just [32:08.230 --> 32:13.270] doesn't seem right, right? So, then I said, well, wait a minute. I have a bunch of models that [32:13.270 --> 32:19.270] haven't finished failing yet. Okay? In other words, they're still in production. So, they could [32:19.270 --> 32:25.250] fail tomorrow. So, I took out all of their drives. I only had to use the drives that we didn't have [32:25.250 --> 32:30.630] in production anymore. So, our data set, those numbers weren't going to change. And it rose all [32:30.630 --> 32:38.350] the way up to two years and seven months, right? Which still feels low. It just doesn't feel right. [32:38.350 --> 32:47.610] And so, just to kind of give you an idea of what we're trying to look at here, the ones in pink [32:47.610 --> 32:52.950] that aren't pink, okay, that have zero drives remaining, those are the ones that I used for that [32:52.950 --> 33:00.010] data set that got me two years and seven months, right? The other drives still have plenty, we [33:00.010 --> 33:06.490] still have plenty of drives in service. So, we can't really use those as a calculation. And if [33:06.490 --> 33:11.750] you look at them, for example, the four terabyte drives, the average age of those is seven years [33:11.750 --> 33:17.530] and one month. So, anything that fails out of that set is certainly going to be older than two [33:18.430 --> 33:27.110] years and six months. So, what I'm saying is, as those drives start to come out, I expect that two [33:27.110 --> 33:31.990] years and six months or two years and seven months to go up to some other number. And we'll [33:31.990 --> 33:37.650] track it over time and see what it looks like, okay? This is just one of these things that you [33:37.650 --> 33:45.170] look at the data, you get an answer, you go, I just don't believe the answer. And then you go [33:45.170 --> 33:51.770] from there. All right. A couple of little fun things that we like to do. Failure rates by, in [33:51.770 --> 33:59.430] this case, drive size. So, we take all of the drives of a given size. Our ten terabyte drives [33:59.430 --> 34:07.730] are doing terrible. Okay. It happens. They get old, they hit the wall. You know, we obviously [34:07.730 --> 34:13.050] had a lot of strategies in place to deal with all of this. It's not an issue. We've been [34:13.050 --> 34:18.810] dealing, you know, we've been around for 16 years. So, we've seen all kinds of different [34:18.810 --> 34:24.550] interesting patterns. But I bring this up because this is what we publish and this is what we [34:24.550 --> 34:30.350] show. And this is the data that's out there. It also gives us an interesting idea to see what's [34:30.350 --> 34:36.530] happening. So, the one that was the surprise was the eight terabyte drives. So, the last couple [34:36.530 --> 34:43.890] of quarters, they suddenly started to jump up. And so, then we had to go in and dig in and see [34:43.890 --> 34:49.930] if it was a particular drive model. It wasn't. It was all of the drives. And we had to go dig in [34:49.930 --> 34:55.590] and see if it had to do something with software changes that we made or location they are. We [34:55.590 --> 34:59.650] had to get all of that out. No. What's just happening is they're just getting to the end of [34:59.650 --> 35:04.770] their life and the failure rate is starting to rise. Right? But we publish this kind of stuff [35:04.770 --> 35:12.570] on a regular basis. We also do this by manufacturer. Okay? And I always put this up and [35:12.570 --> 35:19.850] everybody looks at it and goes, Seagate sucks. Okay? And no, they don't suck. They're a nice [35:19.850 --> 35:24.850] guys, too. They're all nice guys. We have a good relationship with all of them. Right? But you [35:24.850 --> 35:31.670] can see the numbers are rising and they've always been a little high. And so, I wanted to do a [35:31.670 --> 35:38.770] little bit of math for you. Just to show you that sometimes it isn't just the failure rate that [35:38.770 --> 35:44.790] matters. All right? And we publish this model. It's a simplified version of what we do [35:44.790 --> 35:52.290] internally to figure out who we should buy drives from and how much we're going to pay. Right? [35:52.510 --> 35:57.230] And I'm actually going to apply real data to it. But that's the model. You can kind of walk [35:57.230 --> 36:02.730] through it. We pay so much for a drive. Model 1, model 2, model 3. Three different prices. [36:02.770 --> 36:08.310] Right? We buy so many drives. They have three different failure rates. The cheapest one has the [36:08.310 --> 36:13.990] highest failure rate and so on. And you can see the number of failed drives. To replace a drive, [36:13.990 --> 36:18.630] that's 300 bucks for labor. We assume all of them are under warranty. Five-year warranty [36:18.630 --> 36:23.350] because it's a five-year period. So, we're not going to pay and buy any more drives. But if we [36:23.350 --> 36:28.770] did, it would be the same for everybody. And then there's at the bottom, there's a total replacement [36:28.770 --> 36:34.970] total cost. So, the drives plus the maintenance. Again, a little bit simplified, but it'll work [36:34.970 --> 36:43.970] for us. And you can see model 1. Oh, my goodness. I saved almost $200,000 by buying those drives. [36:44.530 --> 36:51.010] Over the lifetime of those drives. That's really, really cool. Right? So, let's use real data. [36:53.070 --> 37:01.890] And so, I put Seagate, Toshiba, and WDC. These are 14 terabyte drives. Right? This is in our [37:01.890 --> 37:08.970] data center, real numbers. And I wanted to break it down. So, the first thing I did is I started [37:08.970 --> 37:15.150] down here and I said, I'm going to make, I'm going to do this math backwards. I'm going to [37:15.150 --> 37:20.690] make the answer the same and let all of the other factors start to change going back up to the top. [37:20.690 --> 37:26.910] In other words, I want to get a number at the top. Right? So, it's going to cost me almost $2.6 [37:26.910 --> 37:35.500] million to buy 10,000 drives and maintain them for five years. And then I put in the failure [37:35.500 --> 37:42.160] rates, the actual failure rates for the lifetime for those drives. Okay? And I put them in. And [37:42.160 --> 37:50.480] those are real. I didn't make them up at all. Right? And what I come up with is the price [37:50.480 --> 38:05.480] I'd be willing to pay to buy those drives. Right? So, I'd be willing to give Seagate $230 and I'd [38:05.480 --> 38:12.600] but there are other factors which come into that. Like I said 10,000 drives. So, if I go to WDC and [38:12.600 --> 38:17.780] I say, hey, I need 10,000 drives, what number can you give me? And they go, I don't have 10,000 of [38:17.780 --> 38:26.200] those. I have 12,000. Okay? And then you go to Toshiba and Toshiba says, well, I have 8,000 but [38:26.200 --> 38:33.220] I can't get them to you until a month from now. Okay? But I'll cut the price down. And so, you [38:33.220 --> 38:39.720] have all of these other factors which make it in. But the point is, okay, this is why we have [38:40.220 --> 38:45.000] drives from different vendors. Okay? When you do all of that kind of math to figure it all out. [38:46.200 --> 38:54.400] All right. So, again, we publish this data on a regular basis. We have all this smart stats. We [38:54.400 --> 38:59.840] have more data coming. Okay? Which will give us the opportunity to share more with the community [38:59.840 --> 39:05.140] because that's what it's all about. We have something called the vault ID. I didn't talk [39:05.140 --> 39:11.980] much about what a vault is. A vault is just an organizational unit for us. 1,200 drives in 20 [39:11.980 --> 39:17.340] servers. Each drive on each server is a tome and so on and so forth. I'm not going to spend any [39:17.340 --> 39:23.580] time with that. But what we get is we can isolate problems then down to a vault, which is, again, [39:24.240 --> 39:30.040] a logical unit or a pod, which is a storage server. And start to see and do the analysis. [39:30.040 --> 39:35.140] Now, our ops guys have been doing this for years. Okay? I just didn't have the data to share with [39:35.140 --> 39:41.760] you. So, we'll be able to share that. We'll also have data center. So, you know that boat that I [39:41.760 --> 39:46.820] showed you earlier? We'll be able to say, is the failure rate any better or worse out in the boat? [39:47.180 --> 39:52.140] Versus our other data center in Phoenix because it's kind of warm down there. Or our other data [39:52.140 --> 39:57.700] center in Sacramento. Or the one in Amsterdam. Is there a problem because the electricity is [39:57.700 --> 40:03.340] different? Who knows, right? And then we'll be able to look at things like failure rates by [40:03.340 --> 40:12.620] server type and data center. And even things like temperature. Right? So, on that boat. Okay? [40:12.620 --> 40:18.000] That's using water cooling instead of air conditioning. What kinds of things are going [40:18.000 --> 40:23.140] on out there? So, those are the kinds of things coming. All right? Lots of fun stuff that we look [40:23.140 --> 40:28.440] at. We've been doing it for years. The data is free. It's out there. You guys can play with it [40:28.900 --> 40:34.940] if you want. You can read the reports if you want. Okay? You can also do analysis for us and [40:34.940 --> 40:41.000] send it to us. Because I'd love to share that with folks. That's what this is all about. So, [40:41.000 --> 40:46.300] all right. If there's any questions, I'll gladly take them now. Or I'll be here for a few minutes. [40:46.300 --> 40:57.640] And we can take it from there. So, any questions in the audience? [40:57.640 --> 40:59.600] Any questions in the audience? [40:59.600 --> 41:02.540] Thanks, Andy. If you have any questions, just come on up to this mic. That way we can hear you [41:02.540 --> 41:10.540] and they can hear you on the DEF CON TV as well. I have one quick question. What drive do you use [41:10.540 --> 41:14.620] at home for backups? I have a Seagate drive. [41:15.160 --> 41:17.420] So, those are HTDs, I assume? [41:17.580 --> 41:20.740] Yeah. Well, yes. They're all HTD Seagates, yeah. [41:20.740 --> 41:21.840] Okay. What size? [41:24.480 --> 41:26.520] I think it's a six terabyte. [41:26.520 --> 41:28.300] Okay. Thank you. [41:30.520 --> 41:38.240] My question is about the SSD and its storage of data. Was that based on power to the chip [41:38.240 --> 41:41.660] or the bit being written to the year of life? [41:43.040 --> 41:44.720] I'm not sure I understand the question. [41:44.720 --> 41:51.800] So, your chart showed that if the SSD wasn't used for a year, it could start to lose data. [41:52.180 --> 41:59.520] Was that meaning that the bit was written to or power applied to the chip? [41:59.520 --> 42:00.560] Power applied. [42:00.560 --> 42:00.920] Okay. [42:00.920 --> 42:01.120] Yeah. [42:01.120 --> 42:01.680] Thank you. [42:01.680 --> 42:02.400] Yeah. [42:04.700 --> 42:11.890] Great. Have you done any special analysis on how vibration maybe influences lifetime of drives? [42:12.880 --> 42:17.240] Yeah. So, that's a good question. Vibration is a tough thing to measure. Technically, [42:17.240 --> 42:23.980] there's a smart stat for that, but it doesn't seem to be populated very well for it. And so, [42:23.980 --> 42:29.020] what you end up doing is, in our case, that's part of what we'll see with the server type. [42:29.540 --> 42:33.940] Because we use different mechanisms in the different servers to lock the drives down [42:33.940 --> 42:39.360] or hold them in place. And that may be one of the things we see. The other thing I have [42:39.360 --> 42:45.080] is anecdotal information from our maintenance records. All of this data, by the way, that I [42:45.080 --> 42:49.780] produce off the drives gets validated against maintenance records before we publish it. [42:49.960 --> 42:57.160] And the maintenance records sometimes have that as a reason, drive vibration. And because [42:57.160 --> 43:01.420] drive vibration actually not only bothers the current drive, it usually bothers the neighbors [43:02.160 --> 43:08.440] as well. So, it's a hard one to say because we should have a stat that gives us that, [43:08.440 --> 43:14.420] but the stat seems to be garbage. And so, we have to rely on just other things. [43:14.900 --> 43:19.060] When we built, when we were building storage servers, the storage pots, [43:19.060 --> 43:23.420] okay, we built multiple versions of them. We had like four different ways that we tried to [43:24.360 --> 43:27.880] minimize vibration. That's one of the things we're going to take a look at now that we have [43:27.880 --> 43:33.120] the storage ID. So, it'll be fun. So, good question. I don't have a really good answer, [43:33.120 --> 43:45.690] sorry. Good to know. Thank you. Kind of in that same vein, have you looked at other correlations, [43:45.690 --> 43:54.170] not just with things happening in the building, but things happening to employees, [43:54.170 --> 43:58.930] to personnel, kind of looking for other explanations for drive failure over time? [43:58.930 --> 44:04.650] Yeah. So, that's a really good thing outside of the technology, the human element a little bit. [44:05.590 --> 44:11.230] Interestingly enough, the maintenance records show that the most because they're all trained [44:11.230 --> 44:15.430] to do the maintenance records a certain way, and they actually have a script that they have [44:15.430 --> 44:22.930] to follow and things of that nature. And when they don't, you can see it. And so, Larry, who's [44:22.930 --> 44:26.990] the guy who runs our global data centers, him and I have that conversation from time to time. [44:27.070 --> 44:32.570] I'll be reading through it and I'll go, you know, Barney doesn't seem to be doing real good on [44:32.570 --> 44:38.790] that stuff. He says, yeah, Barney's no longer with us. So, they do have a process that they're [44:38.790 --> 44:45.850] supposed to follow. It's relatively consistent, but the reality is that sometimes things just [44:45.850 --> 44:52.690] don't go in a straight line, you know. And so, it's an interesting point, but no, we don't. [44:52.690 --> 44:54.030] That's the best we can do. [44:54.030 --> 44:54.670] Gotcha. [44:55.290 --> 45:01.190] All right. Any other questions? If there's not, I will gladly, like I said, I'll be down here if [45:01.190 --> 45:06.450] you have anything else you want to ask and I'll gladly share anything we want. Check it out. [45:06.450 --> 45:12.110] It's fun data, okay. There's no harm, no foul. You can use it, you can don't use it, whatever. [45:13.530 --> 45:14.490] Thank you, Andy. [45:14.790 --> 45:18.290] Thank you, Andy. And the Data Duplication Village is on the other side of that wall, [45:18.290 --> 45:19.570] if you haven't been there before. [45:19.570 --> 45:20.350] Thanks, everyone.