1 00:00:00,000 --> 00:00:00,600 All right. 2 00:00:00,600 --> 00:00:01,240 Hello. 3 00:00:01,240 --> 00:00:02,460 Wow, that's loud. 4 00:00:02,640 --> 00:00:05,620 Hi, this is access control done right the first time. 5 00:00:05,620 --> 00:00:07,540 My name is Tim Clevenger. 6 00:00:07,540 --> 00:00:08,760 A little bit about me. 7 00:00:08,760 --> 00:00:11,620 I'm a network cybersecurity engineer by day. 8 00:00:11,620 --> 00:00:15,720 By night, I'm a low-voltage hardware junkie, vintage computing enthusiast. 9 00:00:15,740 --> 00:00:20,080 In a previous life, I was certified with Linnell and S2 access and video. 10 00:00:20,260 --> 00:00:27,460 And I got to drive around in a truck and look at other systems available in Southern California. 11 00:00:27,780 --> 00:00:29,920 I'm on the Physical Security Village Discord. 12 00:00:29,920 --> 00:00:31,200 My handle is NSFW. 13 00:00:31,200 --> 00:00:33,760 No, I will not tell you why it's my handle. 14 00:00:34,660 --> 00:00:36,300 A little bit about this talk. 15 00:00:36,400 --> 00:00:38,760 You know, we have a lot of talks about bypasses. 16 00:00:38,760 --> 00:00:41,940 My talk is more about the installation of a system. 17 00:00:42,280 --> 00:00:48,340 I'm looking to give some tips and tricks based on the kind of systems that I had seen and had to work on. 18 00:00:48,520 --> 00:00:53,780 A lot of vendors out there, you know, it's a low-bid situation and you get a minimal viable product. 19 00:00:53,880 --> 00:00:59,380 You know, it kind of does the job, but it's not particularly maintainable, reliable, or even secure. 20 00:00:59,480 --> 00:01:02,060 I'm focusing more on large facilities. 21 00:01:02,060 --> 00:01:08,040 You know, if you're a small gym with a single door, some of this will apply to you, but maybe not quite as much. 22 00:01:09,180 --> 00:01:14,480 Just starting off, I have an RFP based on this talk and some other stuff that I've learned. 23 00:01:14,560 --> 00:01:18,520 I'll put this QR code up again at the end in case you can't catch it right now. 24 00:01:19,200 --> 00:01:20,760 So, choosing a system. 25 00:01:20,760 --> 00:01:26,260 Most of the larger vendors use equipment created by a company called Mercury Security. 26 00:01:26,260 --> 00:01:27,620 They're kind of the big gorilla. 27 00:01:27,980 --> 00:01:38,340 They have local storage and independent processing, so you don't have to worry about having to pry open your server room door if your DNS goes down Facebook. 28 00:01:38,640 --> 00:01:42,340 They have multiple vendor support and they are reflashable. 29 00:01:42,340 --> 00:01:54,720 The cool thing about that is if you decide you're tired of Linnell and you want to go with Genentech or Honeywell, they can reflash the firmware on most of your existing equipment and it reduces the amount of hardware that you have to buy to switch vendors. 30 00:01:55,720 --> 00:01:59,160 So, a little bit about system layout considerations. 31 00:01:59,160 --> 00:02:06,220 So, depending on where you're going to do this installation, you'll have a couple of different installation options. 32 00:02:06,240 --> 00:02:09,680 I'll start here with kind of a basic four-door layout. 33 00:02:09,680 --> 00:02:11,900 So, this is a typical enclosure right here. 34 00:02:11,900 --> 00:02:22,800 The top board is your access panel that has all the brains of the operation and makes all of the decisions about whether to let somebody in based on their card number and access rights. 35 00:02:22,800 --> 00:02:26,120 The board below it is an additional door controller that's connected. 36 00:02:26,120 --> 00:02:29,680 That additional controller doesn't have a lot of brains on its own. 37 00:02:29,680 --> 00:02:35,620 It will communicate with that main panel board and that's where the decision happens. 38 00:02:35,620 --> 00:02:43,780 What that means is if you lose communication between those two boards, any of those dumber, cheaper door controller boards become suddenly very dumb. 39 00:02:43,780 --> 00:02:52,780 They will either lock down, lock open, or they'll just use a facility code to grant access, which isn't always the best as far as security goes. 40 00:02:53,920 --> 00:02:57,180 There's an enclosure here, obviously, that houses all of this. 41 00:02:57,480 --> 00:03:00,100 There's a power supply, and then there are batteries. 42 00:03:01,220 --> 00:03:06,680 So, when you go to place this enclosure with your panels in it, there are a couple things to consider. 43 00:03:06,680 --> 00:03:14,320 You know, kind of the obvious stuff like, you know, environment, heat, humidity, power, physical security. 44 00:03:14,320 --> 00:03:19,100 Is this going to be on a wall that people can walk by and pry the, you know, pry the door open on it? 45 00:03:20,080 --> 00:03:28,840 Accessibility, you know, is this going to be up on a ceiling somewhere where maybe your batteries aren't going to get changed regularly because you have to get out a long, you know, step ladder or something? 46 00:03:29,000 --> 00:03:32,580 And then the future, and I'll talk about that here in just a second. 47 00:03:33,180 --> 00:03:42,080 So, for wiring considerations, so the main access panel connects to your server computer that runs the software with Ethernet, typically. 48 00:03:42,620 --> 00:03:46,980 Ethernet, as we know, is kind of a shorter range communications medium. 49 00:03:47,580 --> 00:03:54,920 So, what they have between your access panel and your individual door controllers is called RS-485. 50 00:03:54,920 --> 00:03:59,060 It's an older four-wire communications protocol. 51 00:03:59,700 --> 00:04:02,260 Theoretically, it's good to 4,000 feet. 52 00:04:02,260 --> 00:04:10,420 However, it's much more sensitive to interference than, you know, Ethernet or some of the newer communications technologies. 53 00:04:10,440 --> 00:04:14,100 There's also, there's a foil shield in the wire that you have to deal with. 54 00:04:14,100 --> 00:04:16,760 There's termination at the end of a string of devices. 55 00:04:16,960 --> 00:04:27,200 So, what that means is that RS-485 is substantially, in my opinion, as somebody who's had to go and crawl into spaces and replace wire, it's less reliable over long distances. 56 00:04:27,260 --> 00:04:31,580 But we will see in a minute, there are some places that you just really don't have a choice. 57 00:04:32,020 --> 00:04:35,640 So, next up, we think about our distances to doors. 58 00:04:35,640 --> 00:04:46,900 So, for something like a magnetic lock or a motorized crash bar, that's going to take a lot more amperage than just, you know, a kind of a simple relay-based door opener. 59 00:04:46,900 --> 00:05:04,640 And if that door also happens to be a long way from where you want to place your panel, then you end up with a voltage drop, which causes the locks to either not unlock when you want them to, or in the case of a magnetic lock , the magnet becomes so weak from low voltage that you could just pull the door open anyway. 60 00:05:04,640 --> 00:05:17,000 And what will happen is, when you go to do your installation, the vendor will figure this out after they've already installed the door and installed the panel and run all the wire, and they'll go, okay, well, we're going to need to do a remote power supply. 61 00:05:17,120 --> 00:05:28,260 And what they'll do is they'll find a place up in the ceiling nearest to the door and put the cheapest power supply they possibly can, not having any consideration for the environment it's going to be in. 62 00:05:28,260 --> 00:05:29,760 It's not going to have batteries. 63 00:05:29,760 --> 00:05:31,540 They're not going to tell you where it is. 64 00:05:31,540 --> 00:05:38,760 It's going to be up in a where when you do need to get to it, you're like ripping out drywall or something even more expensive. 65 00:05:39,020 --> 00:05:46,260 So part of your system layout considerations with your project manager is to say, okay, this door is way over here. 66 00:05:46,260 --> 00:05:48,080 Are we going to need a remote power supply? 67 00:05:48,080 --> 00:05:50,080 If so, let's get this going now. 68 00:05:52,260 --> 00:05:55,660 In addition, you know, again, hard lid. 69 00:05:55,660 --> 00:06:02,920 So if you've got that drywall above your closet where you're going to be doing your installation, that's going to affect your installation. 70 00:06:03,160 --> 00:06:11,420 Block walls or concrete walls, like maybe don't put this in a hallway where you're going to have to tunnel through concrete to get all your wiring to your doors. 71 00:06:12,800 --> 00:06:29,100 Integrity and security, you know, I'm going to make sure that if I'm going to have wiring run from my suite over here through a public hallway to this suite over here above a drop ceiling, maybe I'll put that in conduit so it's not easy to get in either tamper with or cut or, 72 00:06:29,100 --> 00:06:30,680 you know, other shenanigans. 73 00:06:31,860 --> 00:06:35,880 So here's one of the two kind of situations that I'm going to talk about. 74 00:06:35,880 --> 00:06:37,580 This is, you know, a warehouse. 75 00:06:37,820 --> 00:06:42,580 We have, you know, 65, 70 doors for trucks to back into. 76 00:06:42,620 --> 00:06:47,600 And then every few doors you have a person door so that somebody can get in and out of the warehouse. 77 00:06:48,060 --> 00:06:50,440 And you want to do access control on these. 78 00:06:50,440 --> 00:07:01,680 Well, you know, we're talking 700 or 800 feet here or maybe more to go from where your access panel might be at the far end across to each one of these drops to these doors. 79 00:07:01,720 --> 00:07:05,560 So what you might do is you might go ahead and use that RS-485. 80 00:07:05,560 --> 00:07:09,000 You know, it's not in a harsh environment so it's probably safe to use. 81 00:07:09,000 --> 00:07:12,700 It's going to be exposed there so if something happens you can get to it. 82 00:07:12,700 --> 00:07:24,760 But it allows you to do this without having to run multiple Ethernet drops or fiber with media converters or whatever it takes to get Ethernet 700 feet down that doorway. 83 00:07:26,700 --> 00:07:28,080 Excuse me. 84 00:07:29,900 --> 00:07:32,840 Here's a kind of a typical Class A office space. 85 00:07:32,840 --> 00:07:36,800 You know, this is a floor in pretty much any Class A building that you'd be into. 86 00:07:36,820 --> 00:07:40,580 So this right here, you know, it's a relatively small space here. 87 00:07:40,580 --> 00:07:50,900 What you probably want to do is a centralized panel somewhere near the elevators where you kind of fan out to all of the doors that you need access to from there. 88 00:07:51,840 --> 00:08:03,480 But something to consider for the future, you know, there might be, oh I don't know, a pandemic and suddenly companies are trying to get rid of excess space because people are working from home. 89 00:08:03,480 --> 00:08:11,320 So if you plan this out ahead of time when you're first moving into the space you can say, you know what, these are pretty much, you know, they're two half offices essentially. 90 00:08:11,320 --> 00:08:13,900 They each have their own elevators, have their own entrance doors. 91 00:08:14,040 --> 00:08:22,620 Maybe I'll go ahead and put a panel on each side and then RS-485 to my doors from there. 92 00:08:22,620 --> 00:08:32,820 And that way if for some reason we need to get rid of half of this floor, it's real easy to just put up some drywall, cut access to that half of the system, and whoever moves in can handle that. 93 00:08:32,880 --> 00:08:35,920 So again, it's just something to consider if you're looking at a space. 94 00:08:36,000 --> 00:08:39,620 Look at how you need to do it today, but also maybe look at the future. 95 00:08:41,340 --> 00:08:43,680 This is a larger installation. 96 00:08:43,680 --> 00:08:45,400 I'm just showing this here for you. 97 00:08:45,400 --> 00:08:47,280 Again, power supply, batteries. 98 00:08:47,280 --> 00:08:53,200 Here we have the access panel at the top with the ethernet drop, and then two door controller boards that are below this. 99 00:08:53,300 --> 00:08:57,780 This is kind of, when you're talking about these centralized panel situations, this is what you typically do. 100 00:08:57,780 --> 00:08:58,920 Use an enclosure. 101 00:08:59,200 --> 00:09:02,220 You have six or eight door controllers. 102 00:09:02,220 --> 00:09:04,000 Each one can control two doors. 103 00:09:04,060 --> 00:09:07,740 And you kind of keep them in one enclosure or two enclosures right next to each other. 104 00:09:07,800 --> 00:09:10,240 The RS-485 runs are really short. 105 00:09:10,240 --> 00:09:13,560 In this case it's a pre-wired panel, so you don't even have to mess with it. 106 00:09:13,560 --> 00:09:22,140 And it just gives you that kind of extra security to have that there instead of saying, I'm going to run a door controller way over on the other side of the building. 107 00:09:22,140 --> 00:09:27,520 And that means that all of that wire from here to there can be a problem in the future. 108 00:09:28,980 --> 00:09:31,500 Now let's talk a little bit about wiring to the doors. 109 00:09:31,620 --> 00:09:42,480 Some of this is a repeat if you've seen some of the bypass stuff already, but I'll try to warp through that part because I think we know how to bypass some of this stuff. 110 00:09:42,480 --> 00:09:48,360 So when you're wiring from your panels to the doors themselves, so some of your wiring considerations. 111 00:09:48,360 --> 00:09:53,700 So you're going to need a power, some heavier gauge wires to the door hardware, whatever unlocks the door. 112 00:09:53,700 --> 00:09:58,100 Motion sensors are going to need a power in addition to their contacts. 113 00:09:58,360 --> 00:10:01,180 You're going to need some kind of shielded cable to the badge reader. 114 00:10:01,180 --> 00:10:04,080 That could be RS-485 or it could be Wigan cable. 115 00:10:04,320 --> 00:10:09,320 You're going to have your door contact and your request to exit wiring is going to need to go on there. 116 00:10:09,320 --> 00:10:17,400 And then it's a good idea to have extra cables, extra conductors there for tamper switches, auxiliary inputs and outputs and that type of thing. 117 00:10:18,220 --> 00:10:25,180 The wrong way to do this is to let your vendors just decide because what they will do is they will find the cheapest wire. 118 00:10:25,260 --> 00:10:31,240 Often it's what they have on the truck and they will run undersized power connectors to doors they think don't need it. 119 00:10:31,320 --> 00:10:36,260 You know, that could be a fire hazard in addition to just, you know, having door opening problems. 120 00:10:36,260 --> 00:10:39,480 They could use unshielded splice cable. 121 00:10:39,480 --> 00:10:47,140 They could use Ethernet or Cat 3 telephone wire if that's what they have access to and that causes communications issues. 122 00:10:47,220 --> 00:11:00,760 And then if they don't have those extra conductors in there, that means that in the future if your receptionist needs a push button to be able to open the door without getting up, I mean, that could involve tunneling under the concrete or up into the ceiling or, 123 00:11:00,760 --> 00:11:07,300 you know, it's a lot of extra work that you could have avoided if you had that already pre-wired with those additional conductors. 124 00:11:07,300 --> 00:11:12,680 So the right way to do this is to specify composite access control cable. 125 00:11:12,840 --> 00:11:16,660 So this is all together in one cable. 126 00:11:16,660 --> 00:11:19,580 It's produced by manufacturers who specialize in this. 127 00:11:19,700 --> 00:11:25,060 It comes in multiple options depending on how many extra conductors you want, how, you know, what kind of locks you're using. 128 00:11:25,200 --> 00:11:34,620 It comes with the right card reader communications cable that's shielded properly, has all the spare conductors, and then it has that thick extra jacket on the outside. 129 00:11:34,640 --> 00:11:43,900 So if they're pulling it through a drop ceiling and they just grind, you know, the cable against a sharp piece of metal, it's less likely to cause damage to the conductors inside. 130 00:11:44,000 --> 00:11:45,040 It's also unique. 131 00:11:45,040 --> 00:11:53,880 You know, a thick yellow cable, they're not going to just go cutting through that, you know, with, you know, willy-nilly like they might a bunch of thin white cables. 132 00:11:55,280 --> 00:11:57,360 A little bit about power supplies and enclosure. 133 00:11:57,360 --> 00:12:05,720 So the way the power works in this situation is typically AC or DC, 12 volts or 24 volts or accommodation of 12 and 24 volts. 134 00:12:05,720 --> 00:12:10,880 Your project manager can help you pick the right system as far as voltage goes. 135 00:12:10,920 --> 00:12:15,440 You want to make sure that they specify one that has a power supply with a charger. 136 00:12:15,780 --> 00:12:17,400 Batteries are extremely important. 137 00:12:17,400 --> 00:12:23,740 The last thing you want is to get locked out of your building when the power goes out because you didn't have batteries on this and all your doors are locked. 138 00:12:24,380 --> 00:12:28,080 Verify the amperage and the temperature range. 139 00:12:28,080 --> 00:12:32,440 This is particularly important if you're going to be putting that enclosure in a hot room. 140 00:12:33,040 --> 00:12:50,000 And then also AC fail and battery fail outputs on the power supply that you can run back to your system and it'll alert you if your batteries are dead or if you're about to, or if you have an AC fail and it's running on batteries, it's good to catch that stuff before your batteries die. 141 00:12:51,820 --> 00:12:56,920 The enclosure, you know, there are different sizes, single or multiple panels in a single enclosure. 142 00:12:56,920 --> 00:13:02,000 You can also chain them together so that you can run multiple stuff in, you know, multiple enclosures. 143 00:13:02,100 --> 00:13:04,980 They're typically sold as a kit with the power supply. 144 00:13:04,980 --> 00:13:09,080 So again, make sure that you get that specified to what you need. 145 00:13:09,320 --> 00:13:14,840 You can get them pre-wired like the one that we saw a couple slides ago, or you can DIY if you want to wire your own. 146 00:13:15,820 --> 00:13:23,040 Make sure you get one that has a tamper switch like you can see in the picture here and a key lock so that you can lock that enclosure. 147 00:13:23,040 --> 00:13:29,080 If it's going to be in a because all these enclosures have the same key. 148 00:13:29,200 --> 00:13:35,640 And then optionally weatherproof if you've got a parking lot with a gate on it way out in the, you know, at the other end of the property. 149 00:13:35,960 --> 00:13:42,460 Maybe put it in the weatherproof enclosure if you don't have a guard shack or someplace to install the panel out there. 150 00:13:43,040 --> 00:13:44,700 And then a little bit about batteries. 151 00:13:44,700 --> 00:13:53,200 I cannot tell you how many times I've seen either no batteries or dead batteries because they hadn't been changed since the system was installed. 152 00:13:53,460 --> 00:13:57,180 They're right in the enclosure, so they're hard to remember sometimes. 153 00:13:57,900 --> 00:14:00,940 Again, you have to have a power supply with charging capability. 154 00:14:01,060 --> 00:14:03,880 What I like to do is write that install date on the battery. 155 00:14:03,880 --> 00:14:10,300 So if you're ever in that enclosure in the future, you can look at and see, you know, how far ahead those batteries are going to need to be replaced. 156 00:14:10,420 --> 00:14:12,280 Typically, I do it every three to five years. 157 00:14:12,280 --> 00:14:16,180 If it's in a nice air conditioned server room, then I'll replace them every five years. 158 00:14:16,280 --> 00:14:22,040 If they're out in a hot, you know, garage or something, then I'll replace them every three years. 159 00:14:22,040 --> 00:14:28,460 You can usually tell because when you pick up the battery and shake it, you'll hear rattling because the electrolytes drying up when the batteries are going dead. 160 00:14:28,600 --> 00:14:30,940 And again, use those battery fail outputs. 161 00:14:30,940 --> 00:14:33,720 I grabbed this out of a hardware guide. 162 00:14:34,040 --> 00:14:47,100 Connect that and run it back to your panels so that you can see when either the batteries are no longer chargeable or if the AC has failed, maybe a breaker has tripped somewhere and you need to go take care of that. 163 00:14:48,660 --> 00:14:50,740 A little bit about those remote power supplies. 164 00:14:50,740 --> 00:14:57,340 Again, for those power hungry locks, make sure that you get those specified out ahead of time during the planning phase. 165 00:14:57,400 --> 00:14:59,660 That way, you know where those are going to go. 166 00:14:59,660 --> 00:15:04,140 You know they're going to be in a place that you can get to and not have to cut through drywall. 167 00:15:04,140 --> 00:15:08,500 You're going to make sure then that it still has the power supply, the charger and the batteries. 168 00:15:08,620 --> 00:15:18,340 You know, having that exterior door on its own power supply with no batteries in it does you no good because that's the door you want to get in when the power goes out. 169 00:15:19,360 --> 00:15:21,420 A little bit about fire safety. 170 00:15:21,740 --> 00:15:27,840 Your doors, the locking mechanism on your door can be either fail safe or fail secure. 171 00:15:27,840 --> 00:15:35,700 What that means is if your access system crashes and it does happen, you want to know whether you can actually get out of the building or not. 172 00:15:35,700 --> 00:15:39,860 If it fails secure, then that door is not going to open when the software is crashed. 173 00:15:39,880 --> 00:15:43,240 If it's fail safe, then the door is going to go unlocked. 174 00:15:43,300 --> 00:15:48,720 Now there's different reasons that people would choose a fail safe versus a fail secure depending on what you're protecting. 175 00:15:48,720 --> 00:15:59,220 I would just say that if you choose to do something that is a fail secure, make sure that people who are in that room can get out in the case of a fire, a power outage, a software crash. 176 00:15:59,440 --> 00:16:03,620 It's not worth life safety to protect assets. 177 00:16:03,620 --> 00:16:05,240 Find another way to do it. 178 00:16:05,460 --> 00:16:12,720 Make sure that your system is going to comply with the local fire code and the authority having jurisdiction. 179 00:16:12,720 --> 00:16:17,400 That's sometimes a fire marshal, sometimes it's a building inspector, depends on your jurisdiction. 180 00:16:17,620 --> 00:16:33,320 And also if you're particularly in a class A building, you may be required by your lease to tie your system into a building fire alarm using a relay like one of these that opens the door or unlocks the lock when the fire alarm goes off. 181 00:16:33,320 --> 00:16:36,100 Again, make sure that you take care of that. 182 00:16:36,100 --> 00:16:38,340 And then finally, there's a box in the U.S. 183 00:16:38,340 --> 00:16:41,000 at least on the outside of most of these buildings. 184 00:16:41,000 --> 00:16:42,280 It's called a Knox box. 185 00:16:42,280 --> 00:16:48,080 It's a little hardened metal box that the fire department can open up to get a key into the building. 186 00:16:48,080 --> 00:16:51,740 I typically will put a badge in there because I don't have keys. 187 00:16:51,740 --> 00:16:52,820 We don't do keys. 188 00:16:52,820 --> 00:16:54,680 But if you do, make sure that's in there. 189 00:16:54,680 --> 00:17:06,700 I strongly recommend that you put a tamper switch in that so that if somebody uses the probably well-known Knox box common keys out there, that you know that that's been tampered with. 190 00:17:07,480 --> 00:17:09,540 A little bit about door hardware. 191 00:17:10,080 --> 00:17:11,460 I'm not going to go through these. 192 00:17:11,460 --> 00:17:13,180 These are, you know, pretty standard. 193 00:17:13,260 --> 00:17:15,940 The electrified strike is the one that you see here. 194 00:17:15,940 --> 00:17:20,120 That's the one that makes the nasty buzzing sound and the door never closes quite right. 195 00:17:20,740 --> 00:17:25,240 Solenoids are the more common ones that you see on office doors. 196 00:17:25,240 --> 00:17:33,900 The only thing with those is if your door is set to stay open 8 to 10 or 12 hours a day, that solenoid is staying engaged that entire time. 197 00:17:33,940 --> 00:17:36,900 And those things can fail prematurely and then you can't open the door. 198 00:17:36,900 --> 00:17:38,640 So it's just something to keep an eye on. 199 00:17:39,140 --> 00:17:49,240 Magnetic locks typically need more power than standard locks because the electromagnet requires that voltage in order to have the holding power. 200 00:17:49,480 --> 00:17:51,300 And those will always fail safe. 201 00:17:51,300 --> 00:17:56,780 So maybe don't use those for your front doors because if the power goes out, they're going to open. 202 00:17:57,140 --> 00:18:03,240 And then finally, motorized crash bars, which I've only seen in one place, but they're expensive, but they're pretty good. 203 00:18:04,620 --> 00:18:07,740 So quick thing about door hardware. 204 00:18:07,740 --> 00:18:09,560 So you have two sensors on a door. 205 00:18:09,560 --> 00:18:14,000 Typically, you have the door contact that tells you whether the door is open or closed. 206 00:18:14,000 --> 00:18:17,800 That can be a reed switch up in the door frame. 207 00:18:17,800 --> 00:18:21,000 It can be integrated into the lock set itself. 208 00:18:21,200 --> 00:18:32,680 And then the request to exit, that's what tells the access control system that this door is being opened legitimately from the inside by the correct person and not being jimmied open from the outside. 209 00:18:32,720 --> 00:18:39,460 So it detects if that door is being forced or bypassed and it still allows the door to open from the secure side. 210 00:18:39,900 --> 00:18:47,940 There's also in cases where you have, for instance, a mag lock, that request to exit switch will actually unlock the door because there's not really any other way to do it. 211 00:18:48,440 --> 00:18:56,660 And then typically, your other options are a button, a buzzer, a motion detector, or a switch integrated into the handle for your Rex. 212 00:18:56,740 --> 00:19:01,040 The reason I mention these is because we need to talk a little bit about supervision. 213 00:19:01,160 --> 00:19:08,540 Supervision is a set of resistors in series or parallel that need to be as close to the door contact or Rex contact as possible. 214 00:19:08,540 --> 00:19:24,620 And what they do is they change your situation from either these wires are open or closed, circuit is open or closed, it gives you now four different readings depending on whether the door is open, the door is closed, or if the wires are cut or the wires are shorted. 215 00:19:24,620 --> 00:19:31,960 And that's very important because the last thing you need is the door contact falling off and then people can just open the door and go in and out. 216 00:19:31,960 --> 00:19:33,300 You don't know what's happened. 217 00:19:35,320 --> 00:19:39,840 Motion detectors, again, there's attack examples here. 218 00:19:39,840 --> 00:19:41,100 We've talked about this quite a bit. 219 00:19:41,100 --> 00:19:44,580 You can come to Physical Security Village and we'll talk you through it. 220 00:19:45,180 --> 00:19:52,640 They're often used to trigger and unlock, again, on motion, I'm sorry, on mag lock doors and some other types. 221 00:19:52,680 --> 00:19:58,700 So not only are they a security risk, but they can actually open the door if you can bypass them. 222 00:19:59,320 --> 00:20:03,580 And then door handle attacks, I know that we just had a presentation on this. 223 00:20:03,580 --> 00:20:13,640 Some of those mitigations, you know, dual Rex, so you have to have something where they pull the door handle on the inside and there's a motion detector or a second badge reader or a push button. 224 00:20:13,700 --> 00:20:17,940 Again, if you're going to use a badge reader to exit, make sure you have a way to get out. 225 00:20:18,160 --> 00:20:24,720 Typically, you get one of those plastic covers that you rip off and pull the handle and they'll let you out while also setting off an alarm. 226 00:20:24,820 --> 00:20:30,560 That's what that's for is so that you can get out in case of a fire and you don't happen to have your badge. 227 00:20:31,580 --> 00:20:33,440 A little bit about badges and readers. 228 00:20:33,440 --> 00:20:36,260 So, you know, badges come in multiple sizes and shapes. 229 00:20:36,260 --> 00:20:38,680 You know, you've got the fobs, you've got the smart card readers. 230 00:20:38,820 --> 00:20:42,040 If you're from the 80s, you've got mag stripe cards, like there's all kinds. 231 00:20:42,440 --> 00:20:45,140 Additional factors, biometrics and pin entry. 232 00:20:45,260 --> 00:20:46,980 This thing here is called a scramble pad. 233 00:20:46,980 --> 00:20:53,080 It's cool every time you hit the button, all the numbers are in a different order so people watch you put your pin in and they still can't figure out what it is. 234 00:20:53,760 --> 00:21:00,540 The badges, the most common types of badges, 125 kilohertz prox, that's what your gym gives you. 235 00:21:01,060 --> 00:21:05,140 1356 megahertz iClass are what you typically get in an office situation. 236 00:21:05,140 --> 00:21:08,800 They're pretty trivially broken and clonable. 237 00:21:08,980 --> 00:21:15,920 The MyFairDes fire and the COs are not broken directly but there are downgrade attacks on those. 238 00:21:17,500 --> 00:21:23,480 Prox and iClass, they have a facility code and a badge ID in a 26-bit format. 239 00:21:23,480 --> 00:21:35,100 The facility code is 0 to 255 and you can buy any badges from eBay or any other vendor with whatever facility code that you want. 240 00:21:35,340 --> 00:21:45,420 So, for instance, most of the places that I've worked, for whatever reason, and this is Texas, California, Utah, the code 132 is the most common facility code. 241 00:21:45,420 --> 00:21:57,680 I have no idea why, but if you bought a batch of 132 codes or cards from eBay and just walked up to a random building, you have a fair chance of getting in. 242 00:21:58,560 --> 00:22:01,780 The, again, the 26-bit Prox and iClass is pretty trivial. 243 00:22:01,780 --> 00:22:13,260 Any compatible reader can read it, so you can just go buy an HID reader off of eBay, attach it to an ESP32, touch your badge to it, it'll give you the facility code and the badge number. 244 00:22:13,640 --> 00:22:15,620 You can also do portable readers. 245 00:22:15,620 --> 00:22:25,160 I know we've had talks about, you know, the clipboard thing where you put a badge reader in your clipboard and you just read people's badges with it. 246 00:22:25,780 --> 00:22:28,020 So the solution is custom badges. 247 00:22:28,180 --> 00:22:31,220 Like I said, there are, there's the MyFair ones. 248 00:22:31,220 --> 00:22:32,140 I've never used those. 249 00:22:32,140 --> 00:22:33,740 I've only used the HIDs. 250 00:22:33,740 --> 00:22:39,780 So they have a format, excuse me, a format called HID Corporate 1000. 251 00:22:39,920 --> 00:22:43,040 It's COs protected, so it's more secure. 252 00:22:43,060 --> 00:22:44,680 It has a dedicated facility code. 253 00:22:44,680 --> 00:22:49,520 When you sign up, your company gets its own facility code because there's millions of possibilities. 254 00:22:49,720 --> 00:22:53,380 And then only you can order more cards with that particular facility code. 255 00:22:53,380 --> 00:22:55,340 These are 48-bit formats. 256 00:22:55,340 --> 00:23:09,920 So for each facility code, you can have 8.3 million badge numbers, which is cool because you can pick a number in the high range and not worry about if you acquire another company, those badge numbers coinciding with somebody else's. 257 00:23:10,340 --> 00:23:13,280 I'm going to warp through this real quick because my time's out. 258 00:23:13,340 --> 00:23:15,880 Make sure you disable older formats on your readers. 259 00:23:15,880 --> 00:23:17,860 That's downgraded. 260 00:23:18,040 --> 00:23:19,980 Badge reader communications, Wigan. 261 00:23:19,980 --> 00:23:22,640 It's a low-speed protocol from 1975. 262 00:23:23,360 --> 00:23:25,880 The mitigation is called OSDP. 263 00:23:25,880 --> 00:23:29,780 OSDP has very few compromises. 264 00:23:29,780 --> 00:23:32,100 They're pretty easy to avoid. 265 00:23:32,100 --> 00:23:38,740 The biggest problem with OSDP is that 84% of installers never or seldom use it. 266 00:23:38,740 --> 00:23:40,300 So it's almost never used these. 267 00:23:40,300 --> 00:23:42,120 And this is from 2015. 268 00:23:42,480 --> 00:23:45,140 So what else should I do? 269 00:23:45,140 --> 00:23:48,660 Test your readers regularly. 270 00:23:49,060 --> 00:23:51,020 Set up alerts in your software. 271 00:23:51,160 --> 00:23:54,580 Again, so many people have software and they've never set up alerts in it. 272 00:23:54,720 --> 00:23:55,720 Document everything. 273 00:23:55,720 --> 00:23:58,460 I put a sticker on the bottom of every reader that has a number. 274 00:23:58,460 --> 00:24:00,920 And I match that number to my access control system. 275 00:24:00,920 --> 00:24:04,860 So when they say reader number 24 is not working, I can just go fix it. 276 00:24:05,080 --> 00:24:06,360 Check your batteries. 277 00:24:06,660 --> 00:24:07,500 Batteries die. 278 00:24:07,500 --> 00:24:09,240 They don't do you any good. 279 00:24:09,380 --> 00:24:11,040 Audit your user list regularly. 280 00:24:11,040 --> 00:24:13,820 And then come visit us in the physical security village. 281 00:24:13,820 --> 00:24:17,260 I'm actually going to be volunteering over there right after this if you have any questions for me. 282 00:24:17,840 --> 00:24:18,980 Thank you very much.