[00:00.000 --> 00:05.820] All right. Hello. Wow, that's loud. Hi, this is access control done right the first time. My name [00:05.820 --> 00:12.140] is Tim Clevenger. A little bit about me. I'm a network cybersecurity engineer by day. By night, [00:12.140 --> 00:16.580] I'm a low-voltage hardware junkie, vintage computing enthusiast. In a previous life, [00:16.580 --> 00:22.060] I was certified with Linnell and S2 access and video. And I got to drive around in a truck and [00:22.060 --> 00:29.060] look at other systems available in Southern California. I'm on the Physical Security [00:29.060 --> 00:33.760] Village Discord. My handle is NSFW. No, I will not tell you why it's my handle. [00:34.660 --> 00:38.760] A little bit about this talk. You know, we have a lot of talks about bypasses. [00:38.760 --> 00:44.620] My talk is more about the installation of a system. I'm looking to give some tips and tricks [00:44.620 --> 00:50.060] based on the kind of systems that I had seen and had to work on. A lot of vendors out there, [00:50.060 --> 00:54.100] you know, it's a low-bid situation and you get a minimal viable product. You know, [00:54.100 --> 00:57.460] it kind of does the job, but it's not particularly maintainable, reliable, [00:57.460 --> 01:03.300] or even secure. I'm focusing more on large facilities. You know, if you're a small gym [01:03.300 --> 01:08.040] with a single door, some of this will apply to you, but maybe not quite as much. [01:09.180 --> 01:14.480] Just starting off, I have an RFP based on this talk and some other stuff that I've learned. [01:14.560 --> 01:18.520] I'll put this QR code up again at the end in case you can't catch it right now. [01:19.200 --> 01:25.600] So, choosing a system. Most of the larger vendors use equipment created by a company called Mercury [01:25.600 --> 01:30.800] Security. They're kind of the big gorilla. They have local storage and independent processing, [01:30.800 --> 01:36.760] so you don't have to worry about having to pry open your server room door if your DNS goes down [01:37.380 --> 01:43.320] Facebook. They have multiple vendor support and they are reflashable. The cool thing about that [01:43.320 --> 01:47.460] is if you decide you're tired of Linnell and you want to go with Genentech or Honeywell, [01:47.460 --> 01:50.660] they can reflash the firmware on most of your existing equipment [01:50.660 --> 01:54.720] and it reduces the amount of hardware that you have to buy to switch vendors. [01:55.720 --> 02:02.340] So, a little bit about system layout considerations. So, depending on where you're [02:02.340 --> 02:06.220] going to do this installation, you'll have a couple of different installation options. [02:06.240 --> 02:11.580] I'll start here with kind of a basic four-door layout. So, this is a typical enclosure right [02:11.580 --> 02:16.840] here. The top board is your access panel that has all the brains of the operation and makes all of [02:16.840 --> 02:22.800] the decisions about whether to let somebody in based on their card number and access rights. [02:22.800 --> 02:26.120] The board below it is an additional door controller that's connected. [02:26.120 --> 02:32.160] That additional controller doesn't have a lot of brains on its own. It will communicate with [02:32.160 --> 02:36.680] that main panel board and that's where the decision happens. What that means is if you [02:36.680 --> 02:41.620] lose communication between those two boards, any of those dumber, cheaper door controller [02:41.620 --> 02:47.260] boards become suddenly very dumb. They will either lock down, lock open, or they'll just [02:47.260 --> 02:52.780] use a facility code to grant access, which isn't always the best as far as security goes. [02:53.920 --> 02:58.760] There's an enclosure here, obviously, that houses all of this. There's a power supply, [02:58.760 --> 03:05.240] and then there are batteries. So, when you go to place this enclosure with your panels in it, [03:05.240 --> 03:09.560] there are a couple things to consider. You know, kind of the obvious stuff like, you know, [03:09.560 --> 03:15.480] environment, heat, humidity, power, physical security. Is this going to be on a wall that [03:15.480 --> 03:20.840] people can walk by and pry the, you know, pry the door open on it? Accessibility, you know, [03:20.840 --> 03:24.680] is this going to be up on a ceiling somewhere where maybe your batteries aren't going to get [03:24.680 --> 03:28.840] changed regularly because you have to get out a long, you know, step ladder or something? [03:29.000 --> 03:32.580] And then the future, and I'll talk about that here in just a second. [03:33.180 --> 03:39.960] So, for wiring considerations, so the main access panel connects to your server computer that runs [03:39.960 --> 03:45.620] the software with Ethernet, typically. Ethernet, as we know, is kind of a shorter range communications [03:45.620 --> 03:53.180] medium. So, what they have between your access panel and your individual door controllers is [03:53.180 --> 04:00.360] called RS-485. It's an older four-wire communications protocol. Theoretically, [04:00.360 --> 04:06.300] it's good to 4,000 feet. However, it's much more sensitive to interference than, you know, [04:06.300 --> 04:11.780] Ethernet or some of the newer communications technologies. There's also, there's a foil [04:11.780 --> 04:15.900] shield in the wire that you have to deal with. There's termination at the end of a string of [04:15.900 --> 04:21.360] devices. So, what that means is that RS-485 is substantially, in my opinion, as somebody who's [04:21.360 --> 04:27.880] had to go and crawl into spaces and replace wire, it's less reliable over long distances. But we [04:27.880 --> 04:31.580] will see in a minute, there are some places that you just really don't have a choice. [04:32.020 --> 04:38.300] So, next up, we think about our distances to doors. So, for something like a magnetic lock [04:38.300 --> 04:42.680] or a motorized crash bar, that's going to take a lot more amperage than just, [04:42.680 --> 04:48.960] you know, a kind of a simple relay-based door opener. And if that door also happens to be a [04:48.960 --> 04:53.700] long way from where you want to place your panel, then you end up with a voltage drop, [04:53.700 --> 04:59.120] which causes the locks to either not unlock when you want them to, or in the case of a magnetic [04:59.120 --> 05:04.640] lock, the magnet becomes so weak from low voltage that you could just pull the door open anyway. [05:04.640 --> 05:09.320] And what will happen is, when you go to do your installation, the vendor will figure this out [05:09.320 --> 05:13.500] after they've already installed the door and installed the panel and run all the wire, [05:13.500 --> 05:17.860] and they'll go, okay, well, we're going to need to do a remote power supply. And what they'll do [05:17.860 --> 05:23.420] is they'll find a place up in the ceiling nearest to the door and put the cheapest power supply they [05:23.420 --> 05:28.680] possibly can, not having any consideration for the environment it's going to be in. It's not [05:28.680 --> 05:32.400] going to have batteries. They're not going to tell you where it is. It's going to be up in a [05:32.400 --> 05:37.940] where when you do need to get to it, you're like ripping out drywall or something even more [05:37.940 --> 05:42.760] expensive. So part of your system layout considerations with your project manager [05:42.760 --> 05:48.580] is to say, okay, this door is way over here. Are we going to need a remote power supply? If so, [05:48.580 --> 05:56.900] let's get this going now. In addition, you know, again, hard lid. So if you've got that drywall [05:56.900 --> 06:01.880] above your closet where you're going to be doing your installation, that's going to affect your [06:01.880 --> 06:07.660] installation. Block walls or concrete walls, like maybe don't put this in a hallway where [06:07.660 --> 06:13.280] you're going to have to tunnel through concrete to get all your wiring to your doors. Integrity [06:13.280 --> 06:18.360] and security, you know, I'm going to make sure that if I'm going to have wiring run from my [06:18.360 --> 06:23.360] suite over here through a public hallway to this suite over here above a drop ceiling, maybe I'll [06:23.360 --> 06:29.860] put that in conduit so it's not easy to get in either tamper with or cut or, you know, other [06:29.860 --> 06:36.400] shenanigans. So here's one of the two kind of situations that I'm going to talk about. This is, [06:36.400 --> 06:43.140] you know, a warehouse. We have, you know, 65, 70 doors for trucks to back into. And then every [06:43.140 --> 06:48.700] few doors you have a person door so that somebody can get in and out of the warehouse. And you want [06:48.700 --> 06:54.340] to do access control on these. Well, you know, we're talking 700 or 800 feet here or maybe more [06:54.340 --> 07:00.860] to go from where your access panel might be at the far end across to each one of these drops to [07:00.860 --> 07:06.360] these doors. So what you might do is you might go ahead and use that RS-485. You know, it's not in [07:06.640 --> 07:10.720] a harsh environment so it's probably safe to use. It's going to be exposed there so if something [07:10.720 --> 07:17.360] happens you can get to it. But it allows you to do this without having to run multiple [07:17.360 --> 07:23.680] Ethernet drops or fiber with media converters or whatever it takes to get Ethernet 700 feet down [07:23.680 --> 07:33.620] that doorway. Excuse me. Here's a kind of a typical Class A office space. You know, this is a floor [07:33.620 --> 07:38.860] in pretty much any Class A building that you'd be into. So this right here, you know, it's a [07:38.860 --> 07:43.740] relatively small space here. What you probably want to do is a centralized panel somewhere near [07:43.740 --> 07:50.900] the elevators where you kind of fan out to all of the doors that you need access to from there. [07:51.840 --> 07:57.040] But something to consider for the future, you know, there might be, oh I don't know, a pandemic and [07:57.040 --> 08:02.840] suddenly companies are trying to get rid of excess space because people are working from [08:02.840 --> 08:07.120] home. So if you plan this out ahead of time when you're first moving into the space you can say, [08:07.120 --> 08:11.560] you know what, these are pretty much, you know, they're two half offices essentially. They each [08:11.560 --> 08:18.920] have their own elevators, have their own entrance doors. Maybe I'll go ahead and put a panel on each [08:18.920 --> 08:25.360] side and then RS-485 to my doors from there. And that way if for some reason we need to get rid of [08:25.360 --> 08:30.760] half of this floor, it's real easy to just put up some drywall, cut access to that half of the system, [08:30.760 --> 08:34.920] and whoever moves in can handle that. So again, it's just something to consider if you're looking [08:34.920 --> 08:39.620] at a space. Look at how you need to do it today, but also maybe look at the future. [08:41.340 --> 08:45.400] This is a larger installation. I'm just showing this here for you. [08:45.400 --> 08:50.020] Again, power supply, batteries. Here we have the access panel at the top with the ethernet drop, [08:50.020 --> 08:54.620] and then two door controller boards that are below this. This is kind of, when you're talking [08:54.620 --> 08:58.920] about these centralized panel situations, this is what you typically do. Use an enclosure. [08:59.200 --> 09:04.920] You have six or eight door controllers. Each one can control two doors. And you kind of keep them [09:04.920 --> 09:10.240] in one enclosure or two enclosures right next to each other. The RS-485 runs are really short. [09:10.240 --> 09:14.300] In this case it's a pre-wired panel, so you don't even have to mess with it. And it just gives you [09:14.300 --> 09:19.720] that kind of extra security to have that there instead of saying, I'm going to run a door [09:19.720 --> 09:24.800] controller way over on the other side of the building. And that means that all of that wire [09:24.800 --> 09:30.820] from here to there can be a problem in the future. Now let's talk a little bit about wiring to the [09:30.820 --> 09:37.000] doors. Some of this is a repeat if you've seen some of the bypass stuff already, but I'll try to [09:37.000 --> 09:42.480] warp through that part because I think we know how to bypass some of this stuff. [09:42.480 --> 09:47.520] So when you're wiring from your panels to the doors themselves, so some of your wiring [09:47.520 --> 09:51.960] considerations. So you're going to need a power, some heavier gauge wires to the door hardware, [09:51.960 --> 09:56.460] whatever unlocks the door. Motion sensors are going to need a power in addition to [09:56.460 --> 10:01.540] their contacts. You're going to need some kind of shielded cable to the badge reader. That could be [10:01.540 --> 10:07.300] RS-485 or it could be Wigan cable. You're going to have your door contact and your request to [10:07.300 --> 10:11.960] exit wiring is going to need to go on there. And then it's a good idea to have extra cables, extra [10:12.640 --> 10:17.400] conductors there for tamper switches, auxiliary inputs and outputs and that type of thing. [10:18.220 --> 10:23.600] The wrong way to do this is to let your vendors just decide because what they will do is they [10:23.600 --> 10:28.400] will find the cheapest wire. Often it's what they have on the truck and they will run undersized [10:28.400 --> 10:33.500] power connectors to doors they think don't need it. You know, that could be a fire hazard in [10:33.500 --> 10:39.480] addition to just, you know, having door opening problems. They could use unshielded splice cable. [10:39.480 --> 10:45.640] They could use Ethernet or Cat 3 telephone wire if that's what they have access to and that causes [10:45.640 --> 10:50.280] communications issues. And then if they don't have those extra conductors in there, that means that [10:50.280 --> 10:55.040] in the future if your receptionist needs a push button to be able to open the door without getting [10:55.040 --> 11:00.940] up, I mean, that could involve tunneling under the concrete or up into the ceiling or, you know, [11:00.940 --> 11:05.660] it's a lot of extra work that you could have avoided if you had that already pre-wired with [11:05.660 --> 11:11.740] those additional conductors. So the right way to do this is to specify composite access control [11:11.740 --> 11:19.580] cable. So this is all together in one cable. It's produced by manufacturers who specialize in this. [11:19.700 --> 11:23.440] It comes in multiple options depending on how many extra conductors you want, how, you know, [11:23.440 --> 11:28.760] what kind of locks you're using. It comes with the right card reader communications cable that's [11:28.760 --> 11:33.840] shielded properly, has all the spare conductors, and then it has that thick extra jacket on the [11:33.840 --> 11:38.360] outside. So if they're pulling it through a drop ceiling and they just grind, you know, the cable [11:38.360 --> 11:44.340] against a sharp piece of metal, it's less likely to cause damage to the conductors inside. It's also [11:44.340 --> 11:48.760] unique. You know, a thick yellow cable, they're not going to just go cutting through that, you [11:48.760 --> 11:56.120] know, with, you know, willy-nilly like they might a bunch of thin white cables. A little bit about [11:56.120 --> 12:01.200] power supplies and enclosure. So the way the power works in this situation is typically AC or DC, [12:01.200 --> 12:07.380] 12 volts or 24 volts or accommodation of 12 and 24 volts. Your project manager can help you pick [12:07.380 --> 12:13.660] the right system as far as voltage goes. You want to make sure that they specify one that has a [12:13.660 --> 12:18.760] power supply with a charger. Batteries are extremely important. The last thing you want is to get [12:18.760 --> 12:22.440] locked out of your building when the power goes out because you didn't have batteries on this and [12:22.440 --> 12:28.680] all your doors are locked. Verify the amperage and the temperature range. This is particularly [12:28.680 --> 12:34.340] important if you're going to be putting that enclosure in a hot room. And then also AC fail [12:34.340 --> 12:40.660] and battery fail outputs on the power supply that you can run back to your system and it'll alert [12:40.660 --> 12:46.160] you if your batteries are dead or if you're about to, or if you have an AC fail and it's running on [12:46.160 --> 12:53.480] batteries, it's good to catch that stuff before your batteries die. The enclosure, you know, [12:53.480 --> 12:57.700] there are different sizes, single or multiple panels in a single enclosure. You can also chain [12:57.700 --> 13:02.420] them together so that you can run multiple stuff in, you know, multiple enclosures. They're [13:02.420 --> 13:08.200] typically sold as a kit with the power supply. So again, make sure that you get that specified to [13:08.200 --> 13:12.900] what you need. You can get them pre-wired like the one that we saw a couple slides ago, or you can [13:12.900 --> 13:18.860] DIY if you want to wire your own. Make sure you get one that has a tamper switch like you can see [13:18.860 --> 13:26.020] in the picture here and a key lock so that you can lock that enclosure. If it's going to be in a [13:26.020 --> 13:31.200] because all these enclosures have the same key. And then optionally weatherproof if you've got [13:31.340 --> 13:35.640] a parking lot with a gate on it way out in the, you know, at the other end of the property. [13:35.960 --> 13:40.380] Maybe put it in the weatherproof enclosure if you don't have a guard shack or someplace to install [13:40.380 --> 13:46.620] the panel out there. And then a little bit about batteries. I cannot tell you how many times I've [13:46.620 --> 13:51.400] seen either no batteries or dead batteries because they hadn't been changed since the [13:51.400 --> 13:57.180] system was installed. They're right in the enclosure, so they're hard to remember sometimes. [13:57.900 --> 14:01.980] Again, you have to have a power supply with charging capability. What I like to do is [14:01.980 --> 14:05.500] write that install date on the battery. So if you're ever in that enclosure in the future, [14:05.500 --> 14:10.300] you can look at and see, you know, how far ahead those batteries are going to need to be replaced. [14:10.420 --> 14:14.420] Typically, I do it every three to five years. If it's in a nice air conditioned server room, [14:14.420 --> 14:18.040] then I'll replace them every five years. If they're out in a hot, you know, [14:18.760 --> 14:23.420] garage or something, then I'll replace them every three years. You can usually tell because when you [14:23.420 --> 14:27.040] pick up the battery and shake it, you'll hear rattling because the electrolytes drying up when [14:27.040 --> 14:32.860] the batteries are going dead. And again, use those battery fail outputs. I grabbed this out of a [14:32.860 --> 14:40.140] hardware guide. Connect that and run it back to your panels so that you can see when either the [14:40.140 --> 14:45.020] batteries are no longer chargeable or if the AC has failed, maybe a breaker has tripped somewhere [14:45.020 --> 14:50.860] and you need to go take care of that. A little bit about those remote power supplies. Again, [14:50.860 --> 14:56.520] for those power hungry locks, make sure that you get those specified out ahead of time during the [14:56.520 --> 15:00.620] planning phase. That way, you know where those are going to go. You know they're going to be [15:00.620 --> 15:05.000] in a place that you can get to and not have to cut through drywall. You're going to make sure [15:05.000 --> 15:09.540] then that it still has the power supply, the charger and the batteries. You know, having that [15:09.540 --> 15:15.400] exterior door on its own power supply with no batteries in it does you no good because that's [15:15.400 --> 15:23.080] the door you want to get in when the power goes out. A little bit about fire safety. Your doors, [15:23.080 --> 15:29.140] the locking mechanism on your door can be either fail safe or fail secure. What that means is if [15:29.140 --> 15:34.700] your access system crashes and it does happen, you want to know whether you can actually get [15:34.700 --> 15:38.880] out of the building or not. If it fails secure, then that door is not going to open when the [15:38.880 --> 15:43.660] software is crashed. If it's fail safe, then the door is going to go unlocked. Now there's [15:43.660 --> 15:47.920] different reasons that people would choose a fail safe versus a fail secure depending on what you're [15:47.920 --> 15:53.240] protecting. I would just say that if you choose to do something that is a fail secure, make sure [15:53.240 --> 15:58.360] that people who are in that room can get out in the case of a fire, a power outage, a software [15:58.360 --> 16:06.360] crash. It's not worth life safety to protect assets. Find another way to do it. Make sure that [16:06.360 --> 16:12.720] your system is going to comply with the local fire code and the authority having jurisdiction. [16:12.720 --> 16:17.400] That's sometimes a fire marshal, sometimes it's a building inspector, depends on your jurisdiction. [16:17.620 --> 16:22.600] And also if you're particularly in a class A building, you may be required by your lease [16:22.600 --> 16:26.920] to tie your system into a building fire alarm using a relay like one of these [16:26.920 --> 16:34.660] that opens the door or unlocks the lock when the fire alarm goes off. Again, make sure that [16:34.660 --> 16:40.000] you take care of that. And then finally, there's a box in the U.S. at least on the outside of most [16:40.000 --> 16:45.260] of these buildings. It's called a Knox box. It's a little hardened metal box that the fire [16:45.260 --> 16:49.920] department can open up to get a key into the building. I typically will put a badge in there [16:49.920 --> 16:55.280] because I don't have keys. We don't do keys. But if you do, make sure that's in there. I strongly [16:55.280 --> 17:00.560] recommend that you put a tamper switch in that so that if somebody uses the probably well-known [17:01.340 --> 17:06.700] Knox box common keys out there, that you know that that's been tampered with. [17:07.480 --> 17:12.280] A little bit about door hardware. I'm not going to go through these. These are, you know, pretty [17:12.280 --> 17:17.380] standard. The electrified strike is the one that you see here. That's the one that makes the nasty [17:17.380 --> 17:23.880] buzzing sound and the door never closes quite right. Solenoids are the more common ones that [17:23.880 --> 17:28.820] you see on office doors. The only thing with those is if your door is set to stay open 8 to 10 or 12 [17:28.820 --> 17:34.860] hours a day, that solenoid is staying engaged that entire time. And those things can fail [17:34.860 --> 17:38.640] prematurely and then you can't open the door. So it's just something to keep an eye on. [17:39.140 --> 17:43.660] Magnetic locks typically need more power than standard locks because the [17:44.900 --> 17:50.680] electromagnet requires that voltage in order to have the holding power. And those will always [17:50.680 --> 17:55.640] fail safe. So maybe don't use those for your front doors because if the power goes out, [17:55.640 --> 17:59.400] they're going to open. And then finally, motorized crash bars, which I've only seen [17:59.400 --> 18:07.740] in one place, but they're expensive, but they're pretty good. So quick thing about door hardware. [18:07.740 --> 18:12.060] So you have two sensors on a door. Typically, you have the door contact that tells you whether [18:12.060 --> 18:18.540] the door is open or closed. That can be a reed switch up in the door frame. It can be [18:18.540 --> 18:23.360] integrated into the lock set itself. And then the request to exit, that's what tells [18:23.360 --> 18:28.840] the access control system that this door is being opened legitimately from the inside by [18:28.840 --> 18:34.460] the correct person and not being jimmied open from the outside. So it detects if that door [18:34.460 --> 18:39.460] is being forced or bypassed and it still allows the door to open from the secure side. [18:39.900 --> 18:44.020] There's also in cases where you have, for instance, a mag lock, that request to exit [18:44.020 --> 18:47.940] switch will actually unlock the door because there's not really any other way to do it. [18:48.440 --> 18:53.620] And then typically, your other options are a button, a buzzer, a motion detector, or [18:54.160 --> 18:58.760] a switch integrated into the handle for your Rex. The reason I mention these is because we [18:58.760 --> 19:03.340] need to talk a little bit about supervision. Supervision is a set of resistors in series [19:03.340 --> 19:08.540] or parallel that need to be as close to the door contact or Rex contact as possible. [19:08.540 --> 19:14.560] And what they do is they change your situation from either these wires are open or closed, [19:14.560 --> 19:20.140] circuit is open or closed, it gives you now four different readings depending on whether the door [19:20.140 --> 19:25.060] is open, the door is closed, or if the wires are cut or the wires are shorted. And that's [19:25.060 --> 19:30.460] very important because the last thing you need is the door contact falling off and then people [19:30.460 --> 19:36.740] can just open the door and go in and out. You don't know what's happened. Motion detectors, [19:38.160 --> 19:41.380] again, there's attack examples here. We've talked about this quite a bit. You can come [19:41.380 --> 19:46.580] to Physical Security Village and we'll talk you through it. They're often used to trigger [19:46.580 --> 19:53.220] and unlock, again, on motion, I'm sorry, on mag lock doors and some other types. So not [19:53.220 --> 19:58.700] only are they a security risk, but they can actually open the door if you can bypass them. [19:59.320 --> 20:03.860] And then door handle attacks, I know that we just had a presentation on this. Some of [20:03.860 --> 20:07.980] those mitigations, you know, dual Rex, so you have to have something where they pull [20:07.980 --> 20:11.900] the door handle on the inside and there's a motion detector or a second badge reader [20:11.900 --> 20:16.800] or a push button. Again, if you're going to use a badge reader to exit, make sure you have a way [20:16.800 --> 20:21.520] to get out. Typically, you get one of those plastic covers that you rip off and pull the [20:21.520 --> 20:26.100] handle and they'll let you out while also setting off an alarm. That's what that's for is so that [20:26.100 --> 20:32.360] you can get out in case of a fire and you don't happen to have your badge. A little bit about [20:32.360 --> 20:36.600] badges and readers. So, you know, badges come in multiple sizes and shapes. You know, you've got [20:36.600 --> 20:40.360] the fobs, you've got the smart card readers. If you're from the 80s, you've got mag stripe [20:40.360 --> 20:45.980] cards, like there's all kinds. Additional factors, biometrics and pin entry. This thing here is [20:45.980 --> 20:49.240] called a scramble pad. It's cool every time you hit the button, all the numbers are in a [20:49.240 --> 20:53.960] different order so people watch you put your pin in and they still can't figure out what it is. [20:53.960 --> 21:01.460] The badges, the most common types of badges, 125 kilohertz prox, that's what your gym gives you. [21:01.460 --> 21:05.940] 1356 megahertz iClass are what you typically get in an office situation. They're pretty [21:05.940 --> 21:12.900] trivially broken and clonable. The MyFairDes fire and the COs are not broken directly but [21:12.900 --> 21:20.720] there are downgrade attacks on those. Prox and iClass, they have a facility code and a badge ID [21:20.720 --> 21:29.740] in a 26-bit format. The facility code is 0 to 255 and you can buy any badges from eBay or any [21:29.740 --> 21:36.900] other vendor with whatever facility code that you want. So, for instance, most of the places [21:36.900 --> 21:44.260] that I've worked, for whatever reason, and this is Texas, California, Utah, the code 132 is the [21:44.260 --> 21:49.960] most common facility code. I have no idea why, but if you bought a batch of 132 codes or cards [21:49.960 --> 21:57.680] from eBay and just walked up to a random building, you have a fair chance of getting in. [21:58.560 --> 22:02.740] The, again, the 26-bit Prox and iClass is pretty trivial. Any compatible reader [22:02.740 --> 22:09.340] can read it, so you can just go buy an HID reader off of eBay, attach it to an ESP32, [22:10.140 --> 22:13.260] touch your badge to it, it'll give you the facility code and the badge number. [22:13.640 --> 22:19.940] You can also do portable readers. I know we've had talks about, you know, the clipboard thing [22:19.940 --> 22:25.160] where you put a badge reader in your clipboard and you just read people's badges with it. [22:25.780 --> 22:31.680] So the solution is custom badges. Like I said, there are, there's the MyFair ones. I've never [22:31.680 --> 22:38.480] used those. I've only used the HIDs. So they have a format, excuse me, a format called HID [22:38.480 --> 22:44.700] Corporate 1000. It's COs protected, so it's more secure. It has a dedicated facility code. When [22:44.700 --> 22:49.520] you sign up, your company gets its own facility code because there's millions of possibilities. [22:49.720 --> 22:53.380] And then only you can order more cards with that particular facility code. [22:53.380 --> 22:58.740] These are 48-bit formats. So for each facility code, you can have 8.3 million badge numbers, [22:58.740 --> 23:03.140] which is cool because you can pick a number in the high range and not worry about if you acquire [23:03.140 --> 23:11.580] another company, those badge numbers coinciding with somebody else's. I'm going to warp through [23:11.580 --> 23:16.160] this real quick because my time's out. Make sure you disable older formats on your readers. That's [23:16.160 --> 23:22.640] downgraded. Badge reader communications, Wigan. It's a low-speed protocol from 1975. [23:23.360 --> 23:32.100] The mitigation is called OSDP. OSDP has very few compromises. They're pretty easy to avoid. [23:32.100 --> 23:38.740] The biggest problem with OSDP is that 84% of installers never or seldom use it. [23:38.740 --> 23:45.660] So it's almost never used these. And this is from 2015. So what else should I do? Test your [23:47.460 --> 23:53.000] readers regularly. Set up alerts in your software. Again, so many people have software and they've [23:53.000 --> 23:57.380] never set up alerts in it. Document everything. I put a sticker on the bottom of every reader [23:57.380 --> 24:01.600] that has a number. And I match that number to my access control system. So when they say [24:01.600 --> 24:07.640] reader number 24 is not working, I can just go fix it. Check your batteries. Batteries die. They [24:07.640 --> 24:12.960] don't do you any good. Audit your user list regularly. And then come visit us in the physical [24:12.960 --> 24:16.020] security village. I'm actually going to be volunteering over there right after this if you [24:16.020 --> 24:18.980] have any questions for me. Thank you very much.