WEBVTT

00:00.000 --> 00:00.600
All right.

00:00.600 --> 00:01.240
Hello.

00:01.240 --> 00:02.460
Wow, that's loud.

00:02.640 --> 00:05.620
Hi, this is access control done right the first time.

00:05.620 --> 00:07.540
My name is Tim Clevenger.

00:07.540 --> 00:08.760
A little bit about me.

00:08.760 --> 00:11.620
I'm a network cybersecurity engineer by day.

00:11.620 --> 00:15.720
By night, I'm a low-voltage hardware junkie, vintage computing enthusiast.

00:15.740 --> 00:20.080
In a previous life, I was certified with Linnell and S2 access and video.

00:20.260 --> 00:27.460
And I got to drive around in a truck and look at other systems available in Southern California.

00:27.780 --> 00:29.920
I'm on the Physical Security Village Discord.

00:29.920 --> 00:31.200
My handle is NSFW.

00:31.200 --> 00:33.760
No, I will not tell you why it's my handle.

00:34.660 --> 00:36.300
A little bit about this talk.

00:36.400 --> 00:38.760
You know, we have a lot of talks about bypasses.

00:38.760 --> 00:41.940
My talk is more about the installation of a system.

00:42.280 --> 00:48.340
I'm looking to give some tips and tricks based on the kind of systems that I had seen and had to work on.

00:48.520 --> 00:53.780
A lot of vendors out there, you know, it's a low-bid situation and you get a minimal viable product.

00:53.880 --> 00:59.380
You know, it kind of does the job, but it's not particularly maintainable, reliable, or even secure.

00:59.480 --> 01:02.060
I'm focusing more on large facilities.

01:02.060 --> 01:08.040
You know, if you're a small gym with a single door, some of this will apply to you, but maybe not quite as much.

01:09.180 --> 01:14.480
Just starting off, I have an RFP based on this talk and some other stuff that I've learned.

01:14.560 --> 01:18.520
I'll put this QR code up again at the end in case you can't catch it right now.

01:19.200 --> 01:20.760
So, choosing a system.

01:20.760 --> 01:26.260
Most of the larger vendors use equipment created by a company called Mercury Security.

01:26.260 --> 01:27.620
They're kind of the big gorilla.

01:27.980 --> 01:38.340
They have local storage and independent processing, so you don't have to worry about having to pry open your server room door if your DNS goes down Facebook.

01:38.640 --> 01:42.340
They have multiple vendor support and they are reflashable.

01:42.340 --> 01:54.720
The cool thing about that is if you decide you're tired of Linnell and you want to go with Genentech or Honeywell, they can reflash the firmware on most of your existing equipment and it reduces the amount of hardware that you have to buy to switch vendors.

01:55.720 --> 01:59.160
So, a little bit about system layout considerations.

01:59.160 --> 02:06.220
So, depending on where you're going to do this installation, you'll have a couple of different installation options.

02:06.240 --> 02:09.680
I'll start here with kind of a basic four-door layout.

02:09.680 --> 02:11.900
So, this is a typical enclosure right here.

02:11.900 --> 02:22.800
The top board is your access panel that has all the brains of the operation and makes all of the decisions about whether to let somebody in based on their card number and access rights.

02:22.800 --> 02:26.120
The board below it is an additional door controller that's connected.

02:26.120 --> 02:29.680
That additional controller doesn't have a lot of brains on its own.

02:29.680 --> 02:35.620
It will communicate with that main panel board and that's where the decision happens.

02:35.620 --> 02:43.780
What that means is if you lose communication between those two boards, any of those dumber, cheaper door controller boards become suddenly very dumb.

02:43.780 --> 02:52.780
They will either lock down, lock open, or they'll just use a facility code to grant access, which isn't always the best as far as security goes.

02:53.920 --> 02:57.180
There's an enclosure here, obviously, that houses all of this.

02:57.480 --> 03:00.100
There's a power supply, and then there are batteries.

03:01.220 --> 03:06.680
So, when you go to place this enclosure with your panels in it, there are a couple things to consider.

03:06.680 --> 03:14.320
You know, kind of the obvious stuff like, you know, environment, heat, humidity, power, physical security.

03:14.320 --> 03:19.100
Is this going to be on a wall that people can walk by and pry the, you know, pry the door open on it?

03:20.080 --> 03:28.840
Accessibility, you know, is this going to be up on a ceiling somewhere where maybe your batteries aren't going to get changed regularly because you have to get out a long, you know, step ladder or something?

03:29.000 --> 03:32.580
And then the future, and I'll talk about that here in just a second.

03:33.180 --> 03:42.080
So, for wiring considerations, so the main access panel connects to your server computer that runs the software with Ethernet, typically.

03:42.620 --> 03:46.980
Ethernet, as we know, is kind of a shorter range communications medium.

03:47.580 --> 03:54.920
So, what they have between your access panel and your individual door controllers is called RS-485.

03:54.920 --> 03:59.060
It's an older four-wire communications protocol.

03:59.700 --> 04:02.260
Theoretically, it's good to 4,000 feet.

04:02.260 --> 04:10.420
However, it's much more sensitive to interference than, you know, Ethernet or some of the newer communications technologies.

04:10.440 --> 04:14.100
There's also, there's a foil shield in the wire that you have to deal with.

04:14.100 --> 04:16.760
There's termination at the end of a string of devices.

04:16.960 --> 04:27.200
So, what that means is that RS-485 is substantially, in my opinion, as somebody who's had to go and crawl into spaces and replace wire, it's less reliable over long distances.

04:27.260 --> 04:31.580
But we will see in a minute, there are some places that you just really don't have a choice.

04:32.020 --> 04:35.640
So, next up, we think about our distances to doors.

04:35.640 --> 04:46.900
So, for something like a magnetic lock or a motorized crash bar, that's going to take a lot more amperage than just, you know, a kind of a simple relay-based door opener.

04:46.900 --> 05:04.640
And if that door also happens to be a long way from where you want to place your panel, then you end up with a voltage drop, which causes the locks to either not unlock when you want them to, or in the case of a magnetic lock , the magnet becomes so weak from low voltage that you could just pull the door open anyway.

05:04.640 --> 05:17.000
And what will happen is, when you go to do your installation, the vendor will figure this out after they've already installed the door and installed the panel and run all the wire, and they'll go, okay, well, we're going to need to do a remote power supply.

05:17.120 --> 05:28.260
And what they'll do is they'll find a place up in the ceiling nearest to the door and put the cheapest power supply they possibly can, not having any consideration for the environment it's going to be in.

05:28.260 --> 05:29.760
It's not going to have batteries.

05:29.760 --> 05:31.540
They're not going to tell you where it is.

05:31.540 --> 05:38.760
It's going to be up in a where when you do need to get to it, you're like ripping out drywall or something even more expensive.

05:39.020 --> 05:46.260
So part of your system layout considerations with your project manager is to say, okay, this door is way over here.

05:46.260 --> 05:48.080
Are we going to need a remote power supply?

05:48.080 --> 05:50.080
If so, let's get this going now.

05:52.260 --> 05:55.660
In addition, you know, again, hard lid.

05:55.660 --> 06:02.920
So if you've got that drywall above your closet where you're going to be doing your installation, that's going to affect your installation.

06:03.160 --> 06:11.420
Block walls or concrete walls, like maybe don't put this in a hallway where you're going to have to tunnel through concrete to get all your wiring to your doors.

06:12.800 --> 06:29.100
Integrity and security, you know, I'm going to make sure that if I'm going to have wiring run from my suite over here through a public hallway to this suite over here above a drop ceiling, maybe I'll put that in conduit so it's not easy to get in either tamper with or cut or,

06:29.100 --> 06:30.680
you know, other shenanigans.

06:31.860 --> 06:35.880
So here's one of the two kind of situations that I'm going to talk about.

06:35.880 --> 06:37.580
This is, you know, a warehouse.

06:37.820 --> 06:42.580
We have, you know, 65, 70 doors for trucks to back into.

06:42.620 --> 06:47.600
And then every few doors you have a person door so that somebody can get in and out of the warehouse.

06:48.060 --> 06:50.440
And you want to do access control on these.

06:50.440 --> 07:01.680
Well, you know, we're talking 700 or 800 feet here or maybe more to go from where your access panel might be at the far end across to each one of these drops to these doors.

07:01.720 --> 07:05.560
So what you might do is you might go ahead and use that RS-485.

07:05.560 --> 07:09.000
You know, it's not in a harsh environment so it's probably safe to use.

07:09.000 --> 07:12.700
It's going to be exposed there so if something happens you can get to it.

07:12.700 --> 07:24.760
But it allows you to do this without having to run multiple Ethernet drops or fiber with media converters or whatever it takes to get Ethernet 700 feet down that doorway.

07:26.700 --> 07:28.080
Excuse me.

07:29.900 --> 07:32.840
Here's a kind of a typical Class A office space.

07:32.840 --> 07:36.800
You know, this is a floor in pretty much any Class A building that you'd be into.

07:36.820 --> 07:40.580
So this right here, you know, it's a relatively small space here.

07:40.580 --> 07:50.900
What you probably want to do is a centralized panel somewhere near the elevators where you kind of fan out to all of the doors that you need access to from there.

07:51.840 --> 08:03.480
But something to consider for the future, you know, there might be, oh I don't know, a pandemic and suddenly companies are trying to get rid of excess space because people are working from home.

08:03.480 --> 08:11.320
So if you plan this out ahead of time when you're first moving into the space you can say, you know what, these are pretty much, you know, they're two half offices essentially.

08:11.320 --> 08:13.900
They each have their own elevators, have their own entrance doors.

08:14.040 --> 08:22.620
Maybe I'll go ahead and put a panel on each side and then RS-485 to my doors from there.

08:22.620 --> 08:32.820
And that way if for some reason we need to get rid of half of this floor, it's real easy to just put up some drywall, cut access to that half of the system, and whoever moves in can handle that.

08:32.880 --> 08:35.920
So again, it's just something to consider if you're looking at a space.

08:36.000 --> 08:39.620
Look at how you need to do it today, but also maybe look at the future.

08:41.340 --> 08:43.680
This is a larger installation.

08:43.680 --> 08:45.400
I'm just showing this here for you.

08:45.400 --> 08:47.280
Again, power supply, batteries.

08:47.280 --> 08:53.200
Here we have the access panel at the top with the ethernet drop, and then two door controller boards that are below this.

08:53.300 --> 08:57.780
This is kind of, when you're talking about these centralized panel situations, this is what you typically do.

08:57.780 --> 08:58.920
Use an enclosure.

08:59.200 --> 09:02.220
You have six or eight door controllers.

09:02.220 --> 09:04.000
Each one can control two doors.

09:04.060 --> 09:07.740
And you kind of keep them in one enclosure or two enclosures right next to each other.

09:07.800 --> 09:10.240
The RS-485 runs are really short.

09:10.240 --> 09:13.560
In this case it's a pre-wired panel, so you don't even have to mess with it.

09:13.560 --> 09:22.140
And it just gives you that kind of extra security to have that there instead of saying, I'm going to run a door controller way over on the other side of the building.

09:22.140 --> 09:27.520
And that means that all of that wire from here to there can be a problem in the future.

09:28.980 --> 09:31.500
Now let's talk a little bit about wiring to the doors.

09:31.620 --> 09:42.480
Some of this is a repeat if you've seen some of the bypass stuff already, but I'll try to warp through that part because I think we know how to bypass some of this stuff.

09:42.480 --> 09:48.360
So when you're wiring from your panels to the doors themselves, so some of your wiring considerations.

09:48.360 --> 09:53.700
So you're going to need a power, some heavier gauge wires to the door hardware, whatever unlocks the door.

09:53.700 --> 09:58.100
Motion sensors are going to need a power in addition to their contacts.

09:58.360 --> 10:01.180
You're going to need some kind of shielded cable to the badge reader.

10:01.180 --> 10:04.080
That could be RS-485 or it could be Wigan cable.

10:04.320 --> 10:09.320
You're going to have your door contact and your request to exit wiring is going to need to go on there.

10:09.320 --> 10:17.400
And then it's a good idea to have extra cables, extra conductors there for tamper switches, auxiliary inputs and outputs and that type of thing.

10:18.220 --> 10:25.180
The wrong way to do this is to let your vendors just decide because what they will do is they will find the cheapest wire.

10:25.260 --> 10:31.240
Often it's what they have on the truck and they will run undersized power connectors to doors they think don't need it.

10:31.320 --> 10:36.260
You know, that could be a fire hazard in addition to just, you know, having door opening problems.

10:36.260 --> 10:39.480
They could use unshielded splice cable.

10:39.480 --> 10:47.140
They could use Ethernet or Cat 3 telephone wire if that's what they have access to and that causes communications issues.

10:47.220 --> 11:00.760
And then if they don't have those extra conductors in there, that means that in the future if your receptionist needs a push button to be able to open the door without getting up, I mean, that could involve tunneling under the concrete or up into the ceiling or,

11:00.760 --> 11:07.300
you know, it's a lot of extra work that you could have avoided if you had that already pre-wired with those additional conductors.

11:07.300 --> 11:12.680
So the right way to do this is to specify composite access control cable.

11:12.840 --> 11:16.660
So this is all together in one cable.

11:16.660 --> 11:19.580
It's produced by manufacturers who specialize in this.

11:19.700 --> 11:25.060
It comes in multiple options depending on how many extra conductors you want, how, you know, what kind of locks you're using.

11:25.200 --> 11:34.620
It comes with the right card reader communications cable that's shielded properly, has all the spare conductors, and then it has that thick extra jacket on the outside.

11:34.640 --> 11:43.900
So if they're pulling it through a drop ceiling and they just grind, you know, the cable against a sharp piece of metal, it's less likely to cause damage to the conductors inside.

11:44.000 --> 11:45.040
It's also unique.

11:45.040 --> 11:53.880
You know, a thick yellow cable, they're not going to just go cutting through that, you know, with, you know, willy-nilly like they might a bunch of thin white cables.

11:55.280 --> 11:57.360
A little bit about power supplies and enclosure.

11:57.360 --> 12:05.720
So the way the power works in this situation is typically AC or DC, 12 volts or 24 volts or accommodation of 12 and 24 volts.

12:05.720 --> 12:10.880
Your project manager can help you pick the right system as far as voltage goes.

12:10.920 --> 12:15.440
You want to make sure that they specify one that has a power supply with a charger.

12:15.780 --> 12:17.400
Batteries are extremely important.

12:17.400 --> 12:23.740
The last thing you want is to get locked out of your building when the power goes out because you didn't have batteries on this and all your doors are locked.

12:24.380 --> 12:28.080
Verify the amperage and the temperature range.

12:28.080 --> 12:32.440
This is particularly important if you're going to be putting that enclosure in a hot room.

12:33.040 --> 12:50.000
And then also AC fail and battery fail outputs on the power supply that you can run back to your system and it'll alert you if your batteries are dead or if you're about to, or if you have an AC fail and it's running on batteries, it's good to catch that stuff before your batteries die.

12:51.820 --> 12:56.920
The enclosure, you know, there are different sizes, single or multiple panels in a single enclosure.

12:56.920 --> 13:02.000
You can also chain them together so that you can run multiple stuff in, you know, multiple enclosures.

13:02.100 --> 13:04.980
They're typically sold as a kit with the power supply.

13:04.980 --> 13:09.080
So again, make sure that you get that specified to what you need.

13:09.320 --> 13:14.840
You can get them pre-wired like the one that we saw a couple slides ago, or you can DIY if you want to wire your own.

13:15.820 --> 13:23.040
Make sure you get one that has a tamper switch like you can see in the picture here and a key lock so that you can lock that enclosure.

13:23.040 --> 13:29.080
If it's going to be in a because all these enclosures have the same key.

13:29.200 --> 13:35.640
And then optionally weatherproof if you've got a parking lot with a gate on it way out in the, you know, at the other end of the property.

13:35.960 --> 13:42.460
Maybe put it in the weatherproof enclosure if you don't have a guard shack or someplace to install the panel out there.

13:43.040 --> 13:44.700
And then a little bit about batteries.

13:44.700 --> 13:53.200
I cannot tell you how many times I've seen either no batteries or dead batteries because they hadn't been changed since the system was installed.

13:53.460 --> 13:57.180
They're right in the enclosure, so they're hard to remember sometimes.

13:57.900 --> 14:00.940
Again, you have to have a power supply with charging capability.

14:01.060 --> 14:03.880
What I like to do is write that install date on the battery.

14:03.880 --> 14:10.300
So if you're ever in that enclosure in the future, you can look at and see, you know, how far ahead those batteries are going to need to be replaced.

14:10.420 --> 14:12.280
Typically, I do it every three to five years.

14:12.280 --> 14:16.180
If it's in a nice air conditioned server room, then I'll replace them every five years.

14:16.280 --> 14:22.040
If they're out in a hot, you know, garage or something, then I'll replace them every three years.

14:22.040 --> 14:28.460
You can usually tell because when you pick up the battery and shake it, you'll hear rattling because the electrolytes drying up when the batteries are going dead.

14:28.600 --> 14:30.940
And again, use those battery fail outputs.

14:30.940 --> 14:33.720
I grabbed this out of a hardware guide.

14:34.040 --> 14:47.100
Connect that and run it back to your panels so that you can see when either the batteries are no longer chargeable or if the AC has failed, maybe a breaker has tripped somewhere and you need to go take care of that.

14:48.660 --> 14:50.740
A little bit about those remote power supplies.

14:50.740 --> 14:57.340
Again, for those power hungry locks, make sure that you get those specified out ahead of time during the planning phase.

14:57.400 --> 14:59.660
That way, you know where those are going to go.

14:59.660 --> 15:04.140
You know they're going to be in a place that you can get to and not have to cut through drywall.

15:04.140 --> 15:08.500
You're going to make sure then that it still has the power supply, the charger and the batteries.

15:08.620 --> 15:18.340
You know, having that exterior door on its own power supply with no batteries in it does you no good because that's the door you want to get in when the power goes out.

15:19.360 --> 15:21.420
A little bit about fire safety.

15:21.740 --> 15:27.840
Your doors, the locking mechanism on your door can be either fail safe or fail secure.

15:27.840 --> 15:35.700
What that means is if your access system crashes and it does happen, you want to know whether you can actually get out of the building or not.

15:35.700 --> 15:39.860
If it fails secure, then that door is not going to open when the software is crashed.

15:39.880 --> 15:43.240
If it's fail safe, then the door is going to go unlocked.

15:43.300 --> 15:48.720
Now there's different reasons that people would choose a fail safe versus a fail secure depending on what you're protecting.

15:48.720 --> 15:59.220
I would just say that if you choose to do something that is a fail secure, make sure that people who are in that room can get out in the case of a fire, a power outage, a software crash.

15:59.440 --> 16:03.620
It's not worth life safety to protect assets.

16:03.620 --> 16:05.240
Find another way to do it.

16:05.460 --> 16:12.720
Make sure that your system is going to comply with the local fire code and the authority having jurisdiction.

16:12.720 --> 16:17.400
That's sometimes a fire marshal, sometimes it's a building inspector, depends on your jurisdiction.

16:17.620 --> 16:33.320
And also if you're particularly in a class A building, you may be required by your lease to tie your system into a building fire alarm using a relay like one of these that opens the door or unlocks the lock when the fire alarm goes off.

16:33.320 --> 16:36.100
Again, make sure that you take care of that.

16:36.100 --> 16:38.340
And then finally, there's a box in the U.S.

16:38.340 --> 16:41.000
at least on the outside of most of these buildings.

16:41.000 --> 16:42.280
It's called a Knox box.

16:42.280 --> 16:48.080
It's a little hardened metal box that the fire department can open up to get a key into the building.

16:48.080 --> 16:51.740
I typically will put a badge in there because I don't have keys.

16:51.740 --> 16:52.820
We don't do keys.

16:52.820 --> 16:54.680
But if you do, make sure that's in there.

16:54.680 --> 17:06.700
I strongly recommend that you put a tamper switch in that so that if somebody uses the probably well-known Knox box common keys out there, that you know that that's been tampered with.

17:07.480 --> 17:09.540
A little bit about door hardware.

17:10.080 --> 17:11.460
I'm not going to go through these.

17:11.460 --> 17:13.180
These are, you know, pretty standard.

17:13.260 --> 17:15.940
The electrified strike is the one that you see here.

17:15.940 --> 17:20.120
That's the one that makes the nasty buzzing sound and the door never closes quite right.

17:20.740 --> 17:25.240
Solenoids are the more common ones that you see on office doors.

17:25.240 --> 17:33.900
The only thing with those is if your door is set to stay open 8 to 10 or 12 hours a day, that solenoid is staying engaged that entire time.

17:33.940 --> 17:36.900
And those things can fail prematurely and then you can't open the door.

17:36.900 --> 17:38.640
So it's just something to keep an eye on.

17:39.140 --> 17:49.240
Magnetic locks typically need more power than standard locks because the electromagnet requires that voltage in order to have the holding power.

17:49.480 --> 17:51.300
And those will always fail safe.

17:51.300 --> 17:56.780
So maybe don't use those for your front doors because if the power goes out, they're going to open.

17:57.140 --> 18:03.240
And then finally, motorized crash bars, which I've only seen in one place, but they're expensive, but they're pretty good.

18:04.620 --> 18:07.740
So quick thing about door hardware.

18:07.740 --> 18:09.560
So you have two sensors on a door.

18:09.560 --> 18:14.000
Typically, you have the door contact that tells you whether the door is open or closed.

18:14.000 --> 18:17.800
That can be a reed switch up in the door frame.

18:17.800 --> 18:21.000
It can be integrated into the lock set itself.

18:21.200 --> 18:32.680
And then the request to exit, that's what tells the access control system that this door is being opened legitimately from the inside by the correct person and not being jimmied open from the outside.

18:32.720 --> 18:39.460
So it detects if that door is being forced or bypassed and it still allows the door to open from the secure side.

18:39.900 --> 18:47.940
There's also in cases where you have, for instance, a mag lock, that request to exit switch will actually unlock the door because there's not really any other way to do it.

18:48.440 --> 18:56.660
And then typically, your other options are a button, a buzzer, a motion detector, or a switch integrated into the handle for your Rex.

18:56.740 --> 19:01.040
The reason I mention these is because we need to talk a little bit about supervision.

19:01.160 --> 19:08.540
Supervision is a set of resistors in series or parallel that need to be as close to the door contact or Rex contact as possible.

19:08.540 --> 19:24.620
And what they do is they change your situation from either these wires are open or closed, circuit is open or closed, it gives you now four different readings depending on whether the door is open, the door is closed, or if the wires are cut or the wires are shorted.

19:24.620 --> 19:31.960
And that's very important because the last thing you need is the door contact falling off and then people can just open the door and go in and out.

19:31.960 --> 19:33.300
You don't know what's happened.

19:35.320 --> 19:39.840
Motion detectors, again, there's attack examples here.

19:39.840 --> 19:41.100
We've talked about this quite a bit.

19:41.100 --> 19:44.580
You can come to Physical Security Village and we'll talk you through it.

19:45.180 --> 19:52.640
They're often used to trigger and unlock, again, on motion, I'm sorry, on mag lock doors and some other types.

19:52.680 --> 19:58.700
So not only are they a security risk, but they can actually open the door if you can bypass them.

19:59.320 --> 20:03.580
And then door handle attacks, I know that we just had a presentation on this.

20:03.580 --> 20:13.640
Some of those mitigations, you know, dual Rex, so you have to have something where they pull the door handle on the inside and there's a motion detector or a second badge reader or a push button.

20:13.700 --> 20:17.940
Again, if you're going to use a badge reader to exit, make sure you have a way to get out.

20:18.160 --> 20:24.720
Typically, you get one of those plastic covers that you rip off and pull the handle and they'll let you out while also setting off an alarm.

20:24.820 --> 20:30.560
That's what that's for is so that you can get out in case of a fire and you don't happen to have your badge.

20:31.580 --> 20:33.440
A little bit about badges and readers.

20:33.440 --> 20:36.260
So, you know, badges come in multiple sizes and shapes.

20:36.260 --> 20:38.680
You know, you've got the fobs, you've got the smart card readers.

20:38.820 --> 20:42.040
If you're from the 80s, you've got mag stripe cards, like there's all kinds.

20:42.440 --> 20:45.140
Additional factors, biometrics and pin entry.

20:45.260 --> 20:46.980
This thing here is called a scramble pad.

20:46.980 --> 20:53.080
It's cool every time you hit the button, all the numbers are in a different order so people watch you put your pin in and they still can't figure out what it is.

20:53.760 --> 21:00.540
The badges, the most common types of badges, 125 kilohertz prox, that's what your gym gives you.

21:01.060 --> 21:05.140
1356 megahertz iClass are what you typically get in an office situation.

21:05.140 --> 21:08.800
They're pretty trivially broken and clonable.

21:08.980 --> 21:15.920
The MyFairDes fire and the COs are not broken directly but there are downgrade attacks on those.

21:17.500 --> 21:23.480
Prox and iClass, they have a facility code and a badge ID in a 26-bit format.

21:23.480 --> 21:35.100
The facility code is 0 to 255 and you can buy any badges from eBay or any other vendor with whatever facility code that you want.

21:35.340 --> 21:45.420
So, for instance, most of the places that I've worked, for whatever reason, and this is Texas, California, Utah, the code 132 is the most common facility code.

21:45.420 --> 21:57.680
I have no idea why, but if you bought a batch of 132 codes or cards from eBay and just walked up to a random building, you have a fair chance of getting in.

21:58.560 --> 22:01.780
The, again, the 26-bit Prox and iClass is pretty trivial.

22:01.780 --> 22:13.260
Any compatible reader can read it, so you can just go buy an HID reader off of eBay, attach it to an ESP32, touch your badge to it, it'll give you the facility code and the badge number.

22:13.640 --> 22:15.620
You can also do portable readers.

22:15.620 --> 22:25.160
I know we've had talks about, you know, the clipboard thing where you put a badge reader in your clipboard and you just read people's badges with it.

22:25.780 --> 22:28.020
So the solution is custom badges.

22:28.180 --> 22:31.220
Like I said, there are, there's the MyFair ones.

22:31.220 --> 22:32.140
I've never used those.

22:32.140 --> 22:33.740
I've only used the HIDs.

22:33.740 --> 22:39.780
So they have a format, excuse me, a format called HID Corporate 1000.

22:39.920 --> 22:43.040
It's COs protected, so it's more secure.

22:43.060 --> 22:44.680
It has a dedicated facility code.

22:44.680 --> 22:49.520
When you sign up, your company gets its own facility code because there's millions of possibilities.

22:49.720 --> 22:53.380
And then only you can order more cards with that particular facility code.

22:53.380 --> 22:55.340
These are 48-bit formats.

22:55.340 --> 23:09.920
So for each facility code, you can have 8.3 million badge numbers, which is cool because you can pick a number in the high range and not worry about if you acquire another company, those badge numbers coinciding with somebody else's.

23:10.340 --> 23:13.280
I'm going to warp through this real quick because my time's out.

23:13.340 --> 23:15.880
Make sure you disable older formats on your readers.

23:15.880 --> 23:17.860
That's downgraded.

23:18.040 --> 23:19.980
Badge reader communications, Wigan.

23:19.980 --> 23:22.640
It's a low-speed protocol from 1975.

23:23.360 --> 23:25.880
The mitigation is called OSDP.

23:25.880 --> 23:29.780
OSDP has very few compromises.

23:29.780 --> 23:32.100
They're pretty easy to avoid.

23:32.100 --> 23:38.740
The biggest problem with OSDP is that 84% of installers never or seldom use it.

23:38.740 --> 23:40.300
So it's almost never used these.

23:40.300 --> 23:42.120
And this is from 2015.

23:42.480 --> 23:45.140
So what else should I do?

23:45.140 --> 23:48.660
Test your readers regularly.

23:49.060 --> 23:51.020
Set up alerts in your software.

23:51.160 --> 23:54.580
Again, so many people have software and they've never set up alerts in it.

23:54.720 --> 23:55.720
Document everything.

23:55.720 --> 23:58.460
I put a sticker on the bottom of every reader that has a number.

23:58.460 --> 24:00.920
And I match that number to my access control system.

24:00.920 --> 24:04.860
So when they say reader number 24 is not working, I can just go fix it.

24:05.080 --> 24:06.360
Check your batteries.

24:06.660 --> 24:07.500
Batteries die.

24:07.500 --> 24:09.240
They don't do you any good.

24:09.380 --> 24:11.040
Audit your user list regularly.

24:11.040 --> 24:13.820
And then come visit us in the physical security village.

24:13.820 --> 24:17.260
I'm actually going to be volunteering over there right after this if you have any questions for me.

24:17.840 --> 24:18.980
Thank you very much.

