[00:00.000 --> 00:04.560] Hi everyone. Thank you so much for coming to my talk. [00:05.140 --> 00:10.280] If you'd like to... I have some detailed slides, so if you'd like to get into those details, [00:10.280 --> 00:15.380] please feel free to click the QR code. I promise it's safe. I don't know how to make it not safe. [00:15.700 --> 00:19.380] So... and follow along for your use. [00:19.960 --> 00:24.960] My name is Lacey Harbour. I have a background in molecular biology, but fell [00:24.960 --> 00:30.060] unfortunately or fortunately into regulatory and quality and clinical studies. [00:30.060 --> 00:34.860] And today, I want to present some ideas to everyone here [00:34.860 --> 00:41.920] about how medical devices are being made and how they're going to be made in the future. [00:41.920 --> 00:46.360] And during this process, I'm going to highlight some areas of concern [00:46.360 --> 00:50.280] that is particularly applicable to our cybersecurity partners. [00:50.280 --> 00:55.660] And how we're not really ready for the future of the medical device [00:55.660 --> 01:00.420] world. So, it goes without saying that [01:00.420 --> 01:05.240] AI is changing everything. AI is particularly changing [01:05.240 --> 01:10.640] the healthcare ecosystem. And this is a good thing for [01:10.640 --> 01:15.600] us because us as a population, we're aging. And our population [01:15.600 --> 01:20.620] isn't growing with new members as much as it used to. With that, [01:20.620 --> 01:25.760] we're going to need a new point of care, new care, standard of care [01:25.760 --> 01:31.260] treatments. And that's not going to be doable without AI. [01:31.660 --> 01:36.040] So, AI being integrated into the products [01:36.040 --> 01:40.600] are changing the scope of these products. And my world is regulatory. [01:40.600 --> 01:45.400] We like to bucket products into regulated and unregulated product. You can have the exact [01:45.400 --> 01:50.500] same instrument or device or whatever. And if you define it to be intended for [01:50.640 --> 01:54.960] a medical purpose like diagnosis, it's a medical device. So, you have all these controls in place [01:54.960 --> 02:00.020] to deal with that product, to develop it, to manage it, to monitor it. [02:00.560 --> 02:05.380] But if it's not a medical device, then you don't have to monitor it to the same level [02:05.380 --> 02:09.780] of scrutiny. And that can be a concern. [02:11.880 --> 02:15.520] So, when something's called a medical [02:15.520 --> 02:20.520] device, particularly in the U.S., it's all depending on its intended use. [02:21.080 --> 02:25.480] Now, with the ecosystem changing, with the scope of the products [02:25.480 --> 02:30.640] changing, the intended use is not just the only thing we need to be worried about or be mindful [02:30.640 --> 02:35.980] of. We need to be mindful of how it's being used in the health care system, [02:35.980 --> 02:40.900] what data sources and attributes it's plugging into. Who are the [02:40.900 --> 02:45.640] end users? It's not just the physician anymore. There's different voice of customers that need to be paid [02:45.640 --> 02:50.920] attention to, especially when you're building a product that should be secure [02:50.920 --> 02:55.700] and safe and effective across the entire use [02:55.700 --> 03:01.320] and its entire ecosystem. In the past, I used to have to be worried [03:01.320 --> 03:06.300] just about the FDA in the U.S. market. Now, I have to be mindful of [03:06.300 --> 03:11.520] all of these entities, these regulatory entities that are listed on the screen. [03:11.620 --> 03:16.280] And that's just the U.S. market. I'm part of an FDA collaborative [03:16.280 --> 03:20.940] community. I'm one of the co-leaders of it. And we have an NLP that just [03:20.940 --> 03:25.780] scans the Internet, picking up sources that we've deemed [03:25.780 --> 03:31.100] reliable and allowing us to analyze all these global sources into a one-stop [03:31.100 --> 03:35.700] shop. Within this year alone, there have been 85 [03:35.700 --> 03:41.060] sources or materials that we as a regulatory equality partners [03:41.060 --> 03:46.100] must analyze and communicate to our companies to take action upon. [03:46.100 --> 03:51.340] And I don't know if you really appreciate how much freaking work that is and how damn near impossible [03:51.340 --> 03:56.020] that is. Because not only do I have to analyze it, and then I have to teach the executives [03:56.020 --> 04:01.400] this information, then I have to get buy-in that they need to update procedures and policies. [04:01.420 --> 04:05.980] We have to do a business risk impact and see how much, you know, it just keeps going and going and going. [04:05.980 --> 04:11.120] Ultimately, you have to train the people within the manufacturing line even what they can [04:11.120 --> 04:16.240] and cannot do. This is a huge task. And of course, it's going to be easier based on the [04:16.240 --> 04:21.260] size of your company or maybe not. Each company has their own problems [04:21.260 --> 04:26.580] with this. It's not just the regulatory ecosystem. [04:26.580 --> 04:32.580] It's also the relationship with our customers. So as medical device manufacturers, [04:32.580 --> 04:35.920] you know, you always think the customer is the physician or the patient. [04:35.920 --> 04:41.060] But that's not always the case. We are plugging in our products into health delivery [04:41.060 --> 04:45.740] organizations. And so they have to navigate their own set of regulations. [04:45.860 --> 04:50.820] And they have their requirements. And so we have to make sure that our products interact [04:50.820 --> 04:56.040] with that. Also, with the future of these products, again, AI enablement [04:56.040 --> 05:00.900] is a really data-hungry process no matter where it's plugged into. And [05:00.900 --> 05:06.000] who owns the data? Well, the EHR companies like Epic. You think they want to [05:06.000 --> 05:10.960] share that data with the medical device manufacturers so that we can have good quality outputs? [05:10.960 --> 05:16.100] Not necessarily. So we have to build those relationships with the medical device manufacturers, [05:16.100 --> 05:21.000] the EMR, and any other applications that are plugging in to the hospital [05:21.000 --> 05:26.260] delivery organization or HDOs. So FDA [05:26.260 --> 05:31.240] is seeing this. And I like to... they're not the only [05:31.240 --> 05:36.260] agency globally that's really making progress. But they are really being public about [05:36.260 --> 05:40.960] it. And it's accessible. Any of you guys can go on the FDA website and see all sorts of [05:40.960 --> 05:46.180] initiatives that they're putting into place to make sure that the public is being heard. [05:46.180 --> 05:50.560] And they're actually engaging patients even. They're really paying attention to the voice of customer [05:50.560 --> 05:54.860] and how these products are truly used. For example, [05:54.860 --> 06:01.020] they'll ask about the workflow in a laboratory even. [06:01.520 --> 06:06.520] And so I highly recommend and encourage everyone to go check out these resources. [06:06.740 --> 06:10.720] But when the FDA is in particular... and they're working with an international [06:10.720 --> 06:15.460] group called the IMDRF. When the FDA is hearing [06:15.460 --> 06:20.820] and seeing where the industry is going, they're [06:20.820 --> 06:25.720] trying to grow along with industry so that they're not holding us [06:25.720 --> 06:30.600] back. And one particular use case I'm going to talk to you guys about today [06:30.600 --> 06:35.620] is called the medical device production system. But before I can get [06:35.620 --> 06:41.240] into this future device, essentially, I want to level set everybody. [06:42.380 --> 06:46.180] Who's here familiar with the total product lifecycle? [06:46.980 --> 06:52.160] I have a handful of people. All right. So the total product lifecycle [06:52.160 --> 06:57.860] is basically the inception of a product all the way to the end of life of a product. [06:57.940 --> 07:02.300] And so I put together here a representation [07:02.300 --> 07:07.880] of any kind of QMS or quality management system that represents a total product lifecycle. [07:07.880 --> 07:12.780] And it looks like a cell. And I really... maybe the biologist is being a little biased [07:12.780 --> 07:17.520] in me, but it really is like feedback loops, like what you get in a cellular function. [07:17.520 --> 07:22.680] So you could break it down, in my mind, a total product lifecycle into design [07:22.680 --> 07:27.540] controls, production and process controls, and then there's feedback loops for improvements. And any of those [07:27.540 --> 07:32.360] improvements could be like failure on the field. It could be a non-conformance from a manufacturing line. [07:32.360 --> 07:37.100] It could be a corrective action that's discovered from anything else or regulatory updates. [07:37.640 --> 07:42.600] But this is too complicated to really talk about and use. [07:42.600 --> 07:47.280] So I further simplified the total product lifecycle schema [07:47.280 --> 07:52.420] into these two basic buckets. So you can see where I have the [07:52.420 --> 07:57.460] QMS and then I've broken it down to design controls and production and [07:57.460 --> 08:03.140] process controls, where you have a prototype of a device. It can be a digital device [08:03.140 --> 08:07.580] or a cyber device, as they call it in the US. It could be [08:08.520 --> 08:11.740] a tongue depressor, depending on the classification. [08:12.300 --> 08:18.020] But say that you have the prototype. You test it. [08:18.020 --> 08:23.160] Hey, it's good. I'm going to now scale up and manufacture this. [08:23.160 --> 08:28.680] So then you transfer to manufacturing. You test it. Hey, the manufacturing is working well. [08:28.680 --> 08:33.140] Now we can actually start mass-producing these products. And then you [08:33.140 --> 08:38.260] manufacture and then you test it again. And then finally, if they match all the quality control [08:38.260 --> 08:43.560] or QC checks, that device is released out into the wild or software or whatever. [08:43.980 --> 08:48.260] Within each of these steps, there's feedback loops. So something bad [08:48.260 --> 08:53.400] can happen during this process to kick you all the way back to design of, you know, feasibility [08:53.400 --> 08:58.200] and design phase. But at the end of the day, the take-home message is [08:58.200 --> 09:03.180] the output, the final device, is from that whole end-to-end total [09:03.180 --> 09:05.420] product lifecycle within the QMS. [09:08.540 --> 09:13.320] Now that I've kind of given you a very high level of the basics of [09:13.320 --> 09:18.620] what currently exists, let's talk about the future. The future of our products [09:18.620 --> 09:23.740] is going to be precise. It's going to be personalized. [09:23.740 --> 09:28.740] It's going to be at the point of care. And there are several different industries [09:28.740 --> 09:33.300] and sectors and technologies that are helping pushing our [09:33.300 --> 09:37.320] standard of care practice to this point. But [09:37.320 --> 09:43.100] the orthopedic sector has really been [09:43.100 --> 09:47.800] leveraging the 3D printing technology to bring us closer [09:47.800 --> 09:52.420] to that precise, personalized, and point-of-care [09:52.420 --> 09:57.380] product. And I'm going to reintroduce the idea of a medical device [09:57.380 --> 10:02.260] production system to you. And so this isn't the only use case [10:02.260 --> 10:07.320] involved that does this. But these orthopedics, I guess [10:07.320 --> 10:12.380] because, I mean, to be honest, it's human carpentry. So the complexity isn't as [10:12.380 --> 10:17.420] much as maybe other devices. So they're moving at a very fast pace. And the FDA [10:17.420 --> 10:22.400] saw that, and so the IMDRF. So they've started to put together some loose guidelines to help [10:22.400 --> 10:26.040] lead this medical device production system. [10:26.840 --> 10:31.380] So what is the medical device production system, or MDPS? [10:31.380 --> 10:36.080] So let's go back again to the schema I showed you all before. Again, [10:36.080 --> 10:40.980] the output is a device, right? It's pretty simple, of a total product [10:40.980 --> 10:46.000] lifecycle of the QMS. Well, a medical production system turns [10:46.000 --> 10:51.100] that on its head. Now, the output, the device, isn't [10:51.100 --> 10:56.400] the final component. And this is a little hard to wrap your head around. It includes [10:56.400 --> 11:01.460] the manufacturing. It includes the design phase. So what happens is [11:01.460 --> 11:06.860] I'm a medical device manufacturer, and I'm going to make a medical device production system, an MDPS. [11:06.860 --> 11:12.060] I'm going to design the production line just as I would before. [11:12.180 --> 11:16.240] Except now, I'm going to realize that this production [11:16.240 --> 11:21.440] system is going to be part of the device in the healthcare delivery organization. [11:21.440 --> 11:25.940] So there will be manufacturing in the hospital. And [11:25.940 --> 11:31.400] then I will allow a certain range of scope or specs that [11:31.400 --> 11:36.540] can be allowed for the hospital to manufacture. And so from that end-to-end process, [11:36.540 --> 11:41.260] they can design the product, and they can manufacture it, and then the output is [11:41.260 --> 11:46.120] part of the entire device. The output alone is no longer the singular device. [11:46.560 --> 11:51.420] So if any of you are familiar with the quality system [11:51.420 --> 11:56.300] regulation or 13485 standards, your wheels may be turning like, how the [11:56.300 --> 12:00.320] hell do you control this? And that is a big question. But [12:01.560 --> 12:06.380] the precursors to this are existing right now. Here I have [12:06.380 --> 12:11.600] an image of some 3D-printed EBM joint implants [12:12.140 --> 12:16.700] made. They're called trabecular titanium, and they allow for bone engrowth. [12:16.700 --> 12:21.680] And they are all patient-matched. And these are printed in the hospital [12:21.680 --> 12:26.700] as we speak from a medical device manufacturer. And so [12:26.700 --> 12:31.080] I'm going to kind of introduce at a high level this current [12:31.080 --> 12:36.280] process, and then we're going to talk about how this is going to become [12:36.280 --> 12:41.220] the medical device production system. So say I'm [12:41.340 --> 12:46.100] a patient, I have a really janked up shoulder, and the physician [12:46.100 --> 12:51.120] says, hey, the standard products on the market, they're not going to work for you. We need to [12:51.120 --> 12:56.200] give you a custom device. So they're going to send me to get a fresh CT scan. I'm going to [12:56.200 --> 13:01.780] get my first CT scan, and that DICOM file is going to go to the radiologist, to the surgeons, [13:01.780 --> 13:06.060] and they're going to segment that file with the medical device [13:06.060 --> 13:11.960] manufacturer or the designer. They will identify the defects, [13:11.960 --> 13:16.380] and then they will agree on how the physician wants to approach it. [13:16.380 --> 13:21.020] So the physician is really close with the designer through this whole process. [13:22.220 --> 13:26.280] After they discuss it, the designer will then take [13:26.280 --> 13:31.160] that DICOM file and convert it to an STL file within a 3D CAD program [13:31.160 --> 13:35.760] like Magix or something similar to that. And they will [13:37.200 --> 13:41.200] propose potential designs. And the designs don't come out of anywhere. It's based [13:41.200 --> 13:46.060] off of historical data, recall data from standard devices, but it will be [13:46.060 --> 13:51.800] matching how the physician wants to perform the surgery and what the physician actually wants to do. [13:51.860 --> 13:56.660] And so there's a feedback loop there until the physician gets the green light, and then it is released. [13:57.720 --> 14:01.380] But just because you can design something doesn't mean you can [14:01.380 --> 14:06.780] actually print it. Within a 3D printer, there's XYZ zones, [14:06.780 --> 14:11.200] and each zone has a different behavior. They're their own animal. [14:11.840 --> 14:16.200] So what happens is that the designer will give the STL file [14:16.200 --> 14:21.240] to the production engineer, and then they will convert it to a machine file and determine [14:21.240 --> 14:26.320] if it's possible to actually 3D print that geometry. And some of that may be tied to [14:26.320 --> 14:31.420] demand planning because you obviously, you have a large bed, and [14:31.420 --> 14:35.140] you may be printing more than one patient's devices at a time. And so [14:36.040 --> 14:40.860] you may have to strategize that. But it's not uncommon for that device to be [14:40.860 --> 14:45.400] kicked back to the physician, essentially, when the production engineer says, [14:45.400 --> 14:50.740] no, we can't do that. After it's printed, there are a lot of supports [14:50.740 --> 14:55.680] that need to be removed. And so typically it's like a CNC or a saw that helps remove [14:55.680 --> 15:00.700] those products, and then it goes to a QC check. And the QC check is just not the [15:00.700 --> 15:04.920] outside dimension, but the inside integrity. These devices have to [15:05.840 --> 15:10.780] resist weight and movement. And so if there's any kind of flaw internally, [15:10.780 --> 15:15.540] that can cause device failure. So there's a lot of checks that have to happen with QC [15:15.540 --> 15:20.740] samples. So what might be of interest is, let's [15:20.740 --> 15:25.700] dissect a little bit more detail of the first half of that from [15:25.700 --> 15:30.220] the relationship of the health delivery organization and the medical device [15:30.220 --> 15:35.800] manufacturer. I'm not going to go into all the detail of every [15:35.800 --> 15:40.100] bit of this schema, but this is just a representation of what that [15:40.900 --> 15:45.400] data interaction might look like. But what I really want to highlight, and I see [15:45.400 --> 15:50.320] some of you shaking your head or maybe have some concerns, you might have noticed that there's [15:50.320 --> 15:55.900] something called a PAC server, and that holds all of the DICOM data for pretty much everything. [15:56.300 --> 16:00.500] And how does that data get to the medical device manufacturer will depend on the relationship [16:00.500 --> 16:05.300] the medical device manufacturer has with the health delivery organization. It could be a nurse [16:05.300 --> 16:10.520] downloading it, it could be on a flash drive and handing it to the device manufacturer, [16:10.520 --> 16:15.500] it could be an email, it could be a CD, or it could be connected directly [16:15.500 --> 16:20.740] into the medical device's server. The medical device [16:20.740 --> 16:25.380] manufacturer may have a software that sits on top of the PAC server, or [16:25.380 --> 16:30.460] they may have a relationship where they have access to the EMR. And now [16:30.460 --> 16:35.600] if they have access to the EMR, they have to have a relationship with the EMR. So the problem [16:35.600 --> 16:40.940] is that I want to highlight is, I just want to make a note [16:40.940 --> 16:46.800] that medical device manufacturers are not HIPAA covered entities. [16:46.800 --> 16:51.120] And I'm just going to leave that there and let you kind of think on what that means. [16:51.520 --> 16:56.300] So once the design [16:56.300 --> 17:01.260] is considered safe, at least from a [17:01.560 --> 17:05.160] failure mode analysis perspective, then it goes back to [17:05.160 --> 17:10.160] the internally. So now we're completely inside the medical [17:10.160 --> 17:13.800] device manufacturer's side of the network. [17:14.880 --> 17:20.540] Many device manufacturers are moving forward to using what's called machine learning operations. [17:20.620 --> 17:25.200] And this is just a high level example of how that [17:25.200 --> 17:30.260] can look within the network. You have containers, of course, that are cross-talking with different [17:31.860 --> 17:35.900] instruments. And then you can also have these containers cross-talking [17:35.900 --> 17:40.720] with other systems, like your product lifecycle management system, [17:40.720 --> 17:45.480] your quality management system, or your ERPs, [17:45.780 --> 17:50.740] or even other sites, if you have multiple sites interacting. And that's something that would be a goal [17:50.740 --> 17:55.740] for medical device manufacturers with MDPS. So it'd be nice to have communications to see the success [17:55.740 --> 18:00.420] of the products across all of your deployed MDPSs. [18:01.460 --> 18:06.640] And so you can see here that there, again, [18:06.640 --> 18:11.440] you may be the design engineer. How did you get the data from the designer? [18:11.440 --> 18:15.500] Well, it could have been put up on a server. It could have been a flash drive handed to you. [18:15.500 --> 18:20.620] And you work on this product for the machine file, the machine planning, on your [18:20.620 --> 18:25.680] personal laptop or on your work laptop, because the data processing for this is [18:25.680 --> 18:31.340] quite substantial. And then how does that data get to the EBM in the first place? [18:31.340 --> 18:36.020] Again, it could be a flash drive. There's a lot of flash drives used in manufacturing, [18:36.020 --> 18:40.620] especially with smaller firms. So there's [18:41.220 --> 18:46.200] concerns there. But this isn't MDPS. [18:46.200 --> 18:51.120] This whole workflow that I presented, it's precursor to MDPS. And it exists [18:51.120 --> 18:56.400] right now. Here are just some firms that are doing this right now. And this isn't even all of them. [18:56.580 --> 19:00.320] There's a lot of research going into how to get the MDPS. [19:02.180 --> 19:06.540] So what is the MDPS? Well, just for simplicity [19:06.540 --> 19:11.040] purposes, think about that whole workflow and put it in a box. [19:11.040 --> 19:16.200] You get the CT scan, you plug that DICOM in this box. There might be [19:16.200 --> 19:21.040] people remote, like designers or even people monitoring the success of the [19:21.040 --> 19:25.860] instrument remotely. And the physician is [19:25.860 --> 19:31.000] working with some kind of software interface to say, hey, I want the design to look this [19:31.000 --> 19:36.060] way. And then they press go and out pops your final device. [19:36.060 --> 19:41.120] Now, if anyone's familiar with 3D printing, the post-processing is going to be a problem for the [19:41.120 --> 19:45.280] future MDPS, but it's not going to be unattainable. [19:45.760 --> 19:50.620] This is, we are working, technology is being researched, mineralization is being researched. [19:50.620 --> 19:54.100] This is not like it's going to be 50 years from now. [19:55.440 --> 20:00.100] What's going to make this even more powerful is that you're going to have feedback from the surgical suite [20:00.100 --> 20:05.360] into the MDPS. So you're going to get clinical outcomes. But again, to get that, you have to [20:05.360 --> 20:08.400] have the relationship with the medical device manufacturer. [20:10.600 --> 20:15.420] So AI is going to be necessary to do this. There's no way [20:15.420 --> 20:20.480] that you're not going to be able to have this without. So let's highlight some of the areas where AI [20:21.200 --> 20:25.240] is being researched even right now and where it's going to be plugged into this MDPS. [20:25.240 --> 20:31.460] I mean, if you look this up online, you're going to see a slew of papers because this is the low-hanging fruit. [20:31.460 --> 20:34.400] Again, human carpentry, everyone's going for this. [20:34.880 --> 20:40.620] First place, automatic segmentation. Have a mask, highlight the defect, [20:40.620 --> 20:45.720] give you recommendations on the defect. The radiologist, the surgeon, or whomever can look at that [20:46.320 --> 20:49.780] and give yes or no feedback. The next place [20:52.080 --> 20:54.560] is the design. [20:54.560 --> 20:58.700] You can have all of your data from your field feedback [20:59.660 --> 21:04.260] from the designs that exist that are standard to automatically generate design. [21:04.260 --> 21:09.340] And all the designer has to do is say go, no go, and the physician [21:09.340 --> 21:14.460] have their inputs as well. And you can use LLMs to generate the surgical technique, [21:14.460 --> 21:19.320] which is also considered part of the labeling, which is part of the design or the device. [21:19.880 --> 21:25.360] Finally, the demand planning, the design transfer. [21:25.740 --> 21:29.860] You can have multiple products in the queue [21:29.860 --> 21:35.700] and you can determine, hey, this device needs to be manufactured in this zone, [21:35.700 --> 21:41.160] but this patient is suicidal, so they're a higher risk. So that would adjust the demand planning. [21:41.160 --> 21:45.900] And that's something, again, you need good connection with the physician and the health [21:45.900 --> 21:51.300] HCPs to determine what's correct. And then, of course, the enabling of manufacturing [21:51.300 --> 21:56.580] with ML is already in progress and they're just going to miniaturize that. [21:56.580 --> 22:01.340] And it would make everything more visible and you can monitor the [22:01.340 --> 22:06.360] manufacturing in real time. So I can't [22:06.360 --> 22:11.340] stress enough that maybe with the high level schemas that I presented to everybody, you might [22:11.340 --> 22:16.420] kind of detect that we, again, are not ready for this, but the technology is getting [22:16.420 --> 22:20.640] there and we need it. We need it now. We need it yesterday. [22:20.960 --> 22:26.360] And so medical device manufacturers need to start being aware of the [22:26.360 --> 22:30.620] three customers down the road so that we can have safe and effective [22:30.620 --> 22:35.660] products that are consented, that are safe, that have [22:35.660 --> 22:40.700] encrypted or private. And that's not something medical device manufacturers are always [22:40.700 --> 22:46.080] mindful of. We are really in a next-gen humanity [22:46.080 --> 22:50.700] moment here. Here's an example of 3D printing [22:50.700 --> 22:56.060] autologous bone. So you have a defect. Instead of a joint implant, [22:56.060 --> 23:01.040] you 3D print a mold that's based off the defect and then you use a bioreactor [23:01.040 --> 23:06.040] to print your bone. It's not just orthopedics. It's just the low-hanging fruit. I mean, [23:06.040 --> 23:10.080] the application is huge and the MDPS is going to be amazing. [23:10.500 --> 23:16.000] So we are in a deus ex-human moment. This is something I [23:16.000 --> 23:21.080] stole from my friend Nina. And it's true. We are making new humans. [23:21.080 --> 23:26.200] And so how are we going to do this safe? I encourage everyone to go to the resources I pointed [23:26.200 --> 23:30.300] out. Kind of look at the schema. What can you do to encourage this and where we can all [23:30.900 --> 23:35.900] have a better future and better health care practice and better standard of care. [23:35.960 --> 23:38.840] So I appreciate everyone. Thank you.