00:00.460 --> 00:01.340
Thank you for coming.

00:01.340 --> 00:02.360
My name is Tim Clevenger.

00:02.360 --> 00:04.820
This is Access Control Dunbright the first time.

00:05.380 --> 00:20.460
By day I'm a network cybersecurity engineer, but in a previous life I worked as a sysadmin for an alarm company that did access control systems and they offered to let me get out of the dark server room and go drive a truck around and install, troubleshoot,

00:20.460 --> 00:25.380
maintain access control systems that had been installed by them and by other companies.

00:25.520 --> 00:40.580
And so working on those systems I just came up with a few kind of tips and tricks to make your access control system, whether you're installing a new one, upgrading, or just doing maintenance to make it a little more maintainable, a little more reliable,

00:40.680 --> 00:41.720
a little more secure.

00:42.300 --> 00:47.720
Many vendors, you know, it's a low bid situation and they'll sell you a minimal viable product.

00:47.720 --> 00:48.200
It'll work.

00:48.200 --> 00:49.580
It'll probably open the doors.

00:49.640 --> 00:56.060
But it's usually not the best for your long term security, I would say.

00:56.660 --> 01:01.600
So when you're choosing a system, there's a company called Mercury Security.

01:01.600 --> 01:05.800
They make the majority of the equipment that is in use in the industry.

01:05.960 --> 01:09.560
There's a bunch of companies that will take that equipment and put their name on it.

01:10.020 --> 01:19.160
It has local storage and onboard processing, so the access panels make all of the decisions on whether to open the door based on the cardholder information.

01:19.280 --> 01:27.680
So if your power goes out and comes back on, you don't have to worry about the board losing its memory and having to reload it, unlike some other vendors that are out there.

01:28.180 --> 01:48.100
The cool thing is because it is firmware reflashable and everybody uses the same boards, if you decide, for instance, that you're not going to use the Linel anymore and you want to go with the Genetech or Honeywell, you can have them come reflash the firmware on most of your boards and be able to switch over to another system without having to buy a whole lot of extra equipment.

01:48.680 --> 01:53.700
So this would be a good time to have a video, but I have pictures of a couple of boards here.

01:53.700 --> 01:56.380
So there's essentially two boards that you'll find in the field.

01:56.520 --> 01:58.200
One of them is called the access panel.

01:58.200 --> 02:04.320
Again, this is the board that makes the decisions or most of the decisions about whether to let somebody in a door.

02:04.520 --> 02:08.340
They're typically connected to your network and to your server over Ethernet.

02:08.740 --> 02:14.960
They have a two-door controller built into them as well, so if you only need two doors, you can get away with just a single board.

02:15.460 --> 02:17.580
And then you have what's called a door controller.

02:17.580 --> 02:23.540
And these are dumber boards, they're a lot cheaper, but they don't store a copy of the cardholder database.

02:23.540 --> 02:37.780
So if something happens and they lose connection, they go into a really dumb mode where it's either everybody's allowed, nobody's allowed, or only people with a certain facility code are allowed, even if they left the company ten years ago and didn't turn their card in.

02:38.540 --> 02:42.980
The way that... and here's another good time for a picture.

02:43.140 --> 02:54.400
So a typical installation, you'll have an enclosure mounted to a wall somewhere, you'll have your access panel again connected with Ethernet, and then you'll have one or more door controllers connected to that.

02:54.420 --> 03:01.140
And then you'll have a power supply with a charger built in and a couple of batteries so that if the power goes out, you're still able to open your doors.

03:01.960 --> 03:13.280
So first thing to consider when you're looking at an access control system and you're working with a project manager at the company or you're putting out an RFP is, where in my building am I going to place my equipment?

03:13.420 --> 03:18.380
So some considerations for that would be like environments, you know, heat, humidity, and dust.

03:18.540 --> 03:30.040
I had to go to work on a system for an HOA and replace the board in one of their pools, their common pools, because it wasn't working reliably when I opened the door.

03:30.040 --> 03:36.080
It's all crusty because they put it in the same room that they put their saltwater pool filtration system.

03:36.200 --> 03:37.900
You're not going to warranty that board.

03:37.900 --> 03:39.420
You're going to have to buy a new one.

03:40.160 --> 03:41.880
Power availability is another one.

03:41.880 --> 03:43.640
Obviously, don't just plug it into an outlet.

03:43.640 --> 03:46.980
You want something that's hardwired with its own circuit breaker.

03:47.320 --> 03:50.000
Physical security, is this going to be in a hallway?

03:50.000 --> 03:53.860
Is it going to be in a closet where maybe unauthorized people are going to get in there?

03:54.240 --> 04:03.720
Maybe put a lock on there and a tamper switch so that it's easy to protect it from somebody just opening the door and tearing out wires.

04:04.060 --> 04:05.560
And then future accessibility.

04:06.040 --> 04:20.220
A lot of times you'll find remote equipment that has been installed by the vendor and they just stick it up in the ceiling and then later it gets drywalled over and then there's wallpaper and if you have to get to that, you're going to, you know, pay somebody to have to fix that up.

04:21.020 --> 04:25.520
So when you're making that decision, I'm going to talk a little bit about wiring.

04:25.520 --> 04:32.440
So you have wiring from your access panel, which again makes all the decisions, to your individual door controllers.

04:32.500 --> 04:38.040
So door controllers, that communication is done with a protocol called RS-485.

04:38.140 --> 04:39.820
It's a protocol from the 80s.

04:39.820 --> 04:46.160
It's typically a 2-wire or 4-wire cable that connects from the panel to the door controller.

04:46.160 --> 04:52.620
There's a shield that has to be like drained at one end and then there's termination at the end of a string.

04:52.780 --> 04:55.780
The theoretical distance is 4,000 feet.

04:55.780 --> 05:04.080
So the first thought from any vendor is, oh, we'll just put a panel here and then we'll just run, you know, 4,000 feet of wires to all of these door controllers.

05:04.080 --> 05:06.000
The problem is they're daisy-chained.

05:06.000 --> 05:09.800
So you go from your panel to your door controller to your door controller to your door controller.

05:09.880 --> 05:30.240
If that wire gets cut in the middle or there's electromagnetic interference because somebody's put a transformer on the other side of the wall, you lose the entire string and then you have to troubleshoot where in all of these devices in this long line of thousands of feet is the problem that's causing me to lose access to all 31 of my door controllers.

05:30.640 --> 05:40.140
So one fault anywhere in there, and that could also mean a failed door controller that's, you know, causing problems on the line, can cause a real issue.

05:40.860 --> 05:46.300
Then you have to think about the controller, the wiring from that door controller to the actual doors.

05:46.440 --> 05:52.760
The card reader wiring also uses RS-485 for newer installations, so there's some consideration there.

05:52.760 --> 06:03.380
But also you have kind of power-hungry locks like magnetic locks or crash bars that can use a lot of electricity and then you're putting a remote power supply out there.

06:03.380 --> 06:07.800
So you kind of have to decide where in my building can I minimize all of these issues.

06:08.500 --> 06:10.440
And then also wire quality.

06:10.440 --> 06:22.880
So typically what I see is a lot of kind of whatever was on the truck or whatever we got at a discount from the place that we buy our wire is going to be what we're going to use.

06:22.880 --> 06:32.280
So the power to our door lock, well, it's a little far for this 18-gauge wire, but we're going to go ahead and run it anyway because that's what we've got.

06:33.100 --> 06:40.340
I've seen spliced wire where they've just kind of, you know, they ran out of wire or something and they spliced it together and maybe it got cut or something.

06:40.660 --> 06:50.760
A lot of unshielded wire, again, for card readers, this is particularly an issue where the card reader can crash and you actually have to unplug it from the panel to get it to start working again.

06:50.760 --> 06:56.720
And then just plain unsuitable wire, like I've seen Ethernet wire used for wiring this stuff.

06:57.800 --> 07:01.680
So the answer to that is called composite access control cable.

07:01.680 --> 07:07.280
It's made by companies that design this for access control applications.

07:07.280 --> 07:08.940
It has all the wires that you need.

07:08.940 --> 07:10.880
They're all shielded where they need to be shielded.

07:10.880 --> 07:17.400
You can get them with auxiliary and spare conductors if you want to run a push button or other stuff.

07:17.400 --> 07:21.340
They're properly shielded, as I mentioned, and then there's like a thick exterior jacket.

07:21.500 --> 07:29.160
But the important thing is if somebody has run this access control cable, you can look at it immediately and go, okay, this is suitable cable.

07:29.160 --> 07:35.360
I don't have to, like, go figure out did they run, you know, too thin a cable for this particular wiring run.

07:36.240 --> 07:39.600
And again, a little bit about those remote power supplies.

07:39.600 --> 07:41.700
They're required for power hungry locks.

07:41.860 --> 07:50.760
Magnetic door locks are the worst for this because if you get too much of a voltage drop, then somebody can just pull on the door really hard and it'll open, but it looks like it's locked.

07:51.520 --> 07:55.960
And what'll happen is sometimes they'll run wire and they'll realize, oh, this is too far.

07:55.960 --> 08:01.880
We're just gonna put a remote power supply up in the ceiling somewhere above a conference room, maybe above the door.

08:01.960 --> 08:04.560
Not necessarily tell you that it's there.

08:04.580 --> 08:09.800
And then when the power goes out and that one door doesn't work, you have to figure out why it is.

08:09.800 --> 08:12.580
And they'll use the cheapest enclosure, the cheapest power supply.

08:12.580 --> 08:13.860
They won't put batteries on it.

08:13.860 --> 08:15.280
It won't have a tamper switch.

08:15.720 --> 08:21.680
So, again, it's something that when you're looking at your layout with your project manager, you can go, okay, this looks like a really long run.

08:21.680 --> 08:24.220
Am I gonna need to do a remote power supply?

08:24.220 --> 08:28.200
If so, let's pick the model and everything right here and make sure it gets batteries.

08:28.200 --> 08:29.620
Make sure it gets documented.

08:29.760 --> 08:33.920
Make sure it's someplace where, again, we're not gonna have to tunnel through a ceiling to get to it.

08:35.220 --> 08:41.560
The preferred layout, at least in my opinion, having done a few of these, is to kind of cluster your equipment.

08:41.560 --> 08:43.280
So, you get a large enclosure.

08:43.720 --> 08:44.860
Hey, hey.

08:46.180 --> 08:51.400
Hi, my name is Tim Clevenger.

08:51.400 --> 08:57.600
This is access... So, this is kind of the preferred way that you want to do this.

08:57.600 --> 09:03.000
You want to cluster your equipment into a single enclosure or a couple of enclosures near each other.

09:03.380 --> 09:05.100
You have your access panel at the top.

09:05.100 --> 09:06.360
You have door controllers.

09:06.360 --> 09:08.700
And you run all your door wiring out from there.

09:09.240 --> 09:16.960
The nice thing about this is, all of your RS-485 wiring, well, in this particular enclosure, it's pre-wired, which is even better.

09:16.960 --> 09:19.260
But it's all nice short runs.

09:19.280 --> 09:23.620
If something happens in here, it's real easy to troubleshoot because it's all right there in one place.

09:25.020 --> 09:32.820
So, typically in an office scenario, you know, you're gonna have, this is like a class A office in a high rise where you have essentially two halves of a building.

09:32.820 --> 09:35.580
There's elevators in the middle that are kind of the common area.

09:35.780 --> 09:43.240
And so, generally, what you want to do is kind of have that cluster just somewhere near the center of the floor.

09:44.520 --> 09:47.320
Don't run RS-485 to another floor.

09:47.420 --> 09:48.740
Don't ask me how I know.

09:49.500 --> 09:56.020
Have that kind of centralized there and maybe you've got to do a remote power supply at the far end if this were a much bigger floor.

09:56.020 --> 09:59.300
But in a situation like this, again, it's all centrally located.

09:59.460 --> 10:09.780
Or, for instance, you might have, I don't know, a pandemic that causes a bunch of folks to work from home and you've got this extra office space that maybe you want to sublease half a floor.

10:09.780 --> 10:17.360
So, maybe when you get this space, you plan out, okay, I'm gonna do a cluster over here that controls this side, a cluster over there that controls that side.

10:17.360 --> 10:26.160
And that way, if we need to sublease it, we can just cut one wire, put up some doors to block off one half of the office space, and then you've still got your half of the office.

10:26.240 --> 10:32.920
And if the sublease ever ends, then you just run the Ethernet again to that access panel, reprogram everything and you're up and running with a whole floor again.

10:33.820 --> 10:38.140
Now, there are some cases where you're gonna be doing RS-485.

10:38.140 --> 10:50.940
So, here, for instance, you know, you have like a warehouse with, you know, 70, 80, 90 docks and, you know, a person door every 10 docks so that, you know, you have a fire escape and maybe somebody can talk to a driver and go back in.

10:51.260 --> 10:56.480
Well, your Ethernet is gonna be, you know, 328 feet is the maximum that you can go.

10:56.480 --> 11:12.660
So, you probably are gonna have to put your access panel at one end and run door controllers just kind of linearly along the wall above all of these doors with a drop every, you know, every 10 doors to be able to open that person door from the outside.

11:13.120 --> 11:14.880
The wiring's exposed.

11:14.880 --> 11:17.920
It's not, you know, there's no EMI, there's no rats up there.

11:17.920 --> 11:20.600
It's real easy to troubleshoot and figure out that way.

11:20.600 --> 11:32.920
So, in that case, you're probably, rather than trying to, like, do Ethernet to all of these and fiber media converters and everything to try to reach, you know, 800 or 1,000 feet, just do that single run of RS-485.

11:33.300 --> 11:45.220
And then you have the gate way at the far end of the parking lot and you've got everything in your building all nice and clustered, you know, one or two clusters on each floor, but you've got that gate out there with a card reader.

11:45.880 --> 11:48.560
Probably your best bet's gonna be RS-485 for that.

11:48.580 --> 11:52.300
Unless you've got a guard shack that has Ethernet, then maybe you do a panel.

11:52.560 --> 11:54.960
But, again, you're running it in a conduit underground.

11:54.960 --> 11:56.360
You can go up to 4,000 feet.

11:56.360 --> 11:59.700
It's one drop because you only need one door controller at the far end.

11:59.700 --> 12:05.260
It's gonna be much more reliable than, you know, having to do it any other way.

12:06.640 --> 12:19.340
So, when you're doing these panels in the enclosures, and this goes for remote power supplies as well, you'll find that, again, we're doing this low-bid, minimum viable product.

12:19.680 --> 12:29.580
These enclosures typically have tamper switches, so if somebody prys open the cover on the thing, you get an alert in your system and you can send somebody out to go figure out who's opened this up and why.

12:29.840 --> 12:31.860
And also this goes for card readers.

12:31.860 --> 12:39.860
There are numerous attacks against card readers, and the first thing that they do is pull the card reader off the wall and attach something to the wires and put it back on the wall.

12:39.860 --> 12:43.060
If you have a tamper, at least you know that that's happened.

12:43.580 --> 12:56.160
And also for a Knox box where you have a key stored, having a tamper on that, again, just helps if somebody prys it off the wall, you know immediately and can disable the card or, you know, rekey the locks or whatever you need to do there.

12:56.420 --> 13:07.400
And typically they just won't do this connection, so make sure that you have that in your RFP or when you're talking to your, you know, your project manager, your salesperson, make sure that you've got that squared away.

13:07.400 --> 13:17.120
I want AC fail, I want battery fail contacts, so that if the power goes out for that one panel for some reason, I know about it instead of waiting for the door to stop working.

13:19.440 --> 13:28.100
I talked a little bit about some of the better locking hardware to deal with motorized crash bars and multi-point locks where you have a lock on the top and the bottom.

13:28.520 --> 13:31.580
And magnetic locks especially take a lot of electricity.

13:31.780 --> 13:43.900
So if you're going to do a long run, you have to look at maybe I'm going to do a remote power supply, maybe I'm going to do 24 volts to this instead of 12 volts because I can use the same wire and run essentially twice the power to it.

13:44.240 --> 13:54.420
But it's something that you need to consider because again a magnetic lock, a lot of times if that thing's got some voltage drop, it'll look like it's locked and it'll rattle like it's locked, but if you pull hard enough it'll just pop open.

13:55.060 --> 13:57.460
And then any doors that have solenoids.

13:57.460 --> 14:02.840
I've seen this happen a few times, just kind of standard solenoid unlocked doors.

14:02.920 --> 14:10.180
If you have, you know, this door is unlocked during business hours, eight to ten or twelve hours a day, you may notice that the handle feels warm.

14:10.280 --> 14:17.780
It's because that solenoid is constantly activated during business hours and it can fail on you and then you can't open the door at all.

14:17.860 --> 14:23.980
So it's just something to keep an eye out for and make sure you have something that, you know, maybe is better suited for that particular door.

14:25.260 --> 14:34.940
You know, motion sensors are used to determine whether somebody is leaving, opening the door from the inside legitimately as opposed to prying it open from the outside.

14:35.400 --> 14:40.300
They generally require separate power, so make sure that you're accounting for that when you're running your wire.

14:40.960 --> 14:47.720
They have a, you know, essentially heat or infrared or microwave or both as a way that they detect movement.

14:48.500 --> 14:50.740
Aim and detection range is important on these.

14:51.060 --> 15:00.380
First of all, because there's bypasses, you know, you can do the spray through the doors or the, you know, under the handle door opening.

15:00.680 --> 15:05.240
Or you can get false trips, which, you know, sends a guard out there for no reason.

15:05.500 --> 15:16.580
You also have, you know, this thing is aimed at a door, but it's in a hallway, and every time somebody walks by, it goes click, click, click, click, click, which, you know, drives people crazy who are sitting near it.

15:18.540 --> 15:23.380
So those door sensors I was talking about, a door contact, so that detects if the door is open or closed.

15:23.380 --> 15:34.420
And the REX, or request to exit, that, again, is a micro switch or a motion detector or even a push button that says this door is about to open legitimately from the inside with somebody leaving.

15:34.460 --> 15:36.220
There's bypasses for all of those.

15:36.220 --> 15:40.100
Again, kind of think about that when you're deciding what you want to do there.

15:40.320 --> 15:44.360
What is almost never done are supervision resistors.

15:44.420 --> 15:55.480
These are basically put in line as close to the door contact as possible, and what they do is they change the signal from either this line is open and this line is shorted.

15:55.480 --> 15:59.200
It changes it to four different resistance levels.

15:59.200 --> 16:03.360
This line is shorted, this line is opened, or the door is open or the door is closed.

16:03.480 --> 16:15.000
So it allows you to, it allows the system to detect, again, if somebody, you know, cuts the wires or splices them together or the door contact falls off, it helps you troubleshoot that a little bit better.

16:15.000 --> 16:16.600
These things are like a buck and a half.

16:16.600 --> 16:19.600
It is sheer laziness that companies do not install these.

16:21.860 --> 16:24.860
A little bit about life safety, because that's very important.

16:25.300 --> 16:27.800
There's fail-safe versus fail-secure locks.

16:27.800 --> 16:39.520
And what that means is, if the software crashes, is this door going to fail safe, meaning that somebody can open the door to get out, or is it going to fail secure where the door is not going to open?

16:40.100 --> 16:44.340
Always make sure that you set that up to allow people to escape.

16:44.460 --> 16:48.100
It's never worth risking people's lives to protect property.

16:48.920 --> 16:53.320
Coordinate with your local fire code and your authority having jurisdiction.

16:53.460 --> 17:02.520
Some areas, that's a fire marshal, sometimes it's a building inspector, but make sure that you have a way for people to escape if there's an emergency.

17:03.200 --> 17:18.540
If you are in a high-rise building, again, you'll have a building fire alarm, and usually part of your lease, and probably part of the fire code, is that you connect your system using these relays so that if the fire alarm goes off, it automatically unlocks doors so that people can escape.

17:19.020 --> 17:21.320
And then finally, a Knox box, you may have seen these.

17:21.320 --> 17:23.720
They're typically attached to the outside of the building.

17:23.740 --> 17:31.980
They have a special key that the fire department, and probably bad guys have, that they can open it up and get a key or a card out of there to get into a building in case of an emergency.

17:32.240 --> 17:37.000
Again, I would put a tamper on that, because you really don't know who's cloned that key or who has that key.

17:39.120 --> 17:42.040
So, a little quick thing about badges and readers here.

17:43.540 --> 17:49.500
Badge readers come in different shapes and sizes and strengths, depending on what you're going to be reading.

17:49.640 --> 17:52.920
Additional factors, including biometrics and pin entry, are available.

17:52.920 --> 18:06.580
I typically love to have pin entry on high security doors, like maybe your server room, because it keeps anybody from having cloned or stolen a badge from immediately getting in, unless somebody wrote the pin on the back of the card.

18:07.960 --> 18:09.680
There's different badge types.

18:09.680 --> 18:11.240
I only have a few here.

18:11.240 --> 18:14.240
The 125 kilohertz prox, those are really trivial to break.

18:14.240 --> 18:18.120
Those are the ones you get from your gym and your apartment complex's parking garage.

18:18.120 --> 18:20.300
They're the cheapest systems that you can get.

18:20.420 --> 18:25.420
The higher frequency iClass ones are also pretty well broken by now.

18:25.480 --> 18:30.720
There are some others, like the Desfire V2 and above, that's maybe not broken.

18:30.720 --> 18:34.720
There's some kind of workarounds on some of these.

18:34.780 --> 18:37.500
And then the HIDCOS is also not broken.

18:37.520 --> 18:40.160
Again, asterisk.

18:41.700 --> 18:45.780
So, the prox and the iClass, they have a facility code and a badge ID.

18:46.140 --> 18:52.780
You have 256 facility codes to choose from in the 26-bit format.

18:52.940 --> 19:00.040
You can buy the cards from your vendor or eBay or other places with the facility code that you want.

19:00.040 --> 19:10.300
For some reason, I've seen more than any other codes, obviously one, but I've also seen 132 as a code that a lot of people get.

19:10.300 --> 19:12.700
So, maybe don't get those.

19:13.500 --> 19:16.160
Again, prox and iClass, you can clone them.

19:16.160 --> 19:18.960
Any compatible reader that you get off eBay can read those cards.

19:19.040 --> 19:26.840
And then the data can be captured from a portable reader, like one that you attach to batteries and stick in a briefcase and go get people's cards.

19:27.360 --> 19:29.560
The solution for that is custom badges.

19:29.560 --> 19:30.780
Again, there's many different ones.

19:30.780 --> 19:31.980
These are the ones I'm familiar with.

19:31.980 --> 19:34.040
It's called HID Corporate 1000.

19:34.340 --> 19:37.560
It's COS compatible, so it's more secure.

19:37.840 --> 19:39.480
You get a dedicated facility code.

19:39.480 --> 19:46.920
Nobody can order that same facility code except for specific employees from your company from your preferred vendor.

19:47.260 --> 19:51.540
And because it's a 48-bit format, you have 8 million badge numbers to choose from.

19:51.540 --> 19:57.760
So, you can pick a range from way up high and not have to worry about acquiring a competitor.

19:57.760 --> 19:59.600
Then you've got the same badge numbers.

20:00.060 --> 20:03.780
When you use a system like this, make sure you disable the older formats.

20:03.780 --> 20:06.540
Otherwise, people can still use an old prox.

20:07.860 --> 20:11.800
So, Badger Communications Weekend is the one that's still being used.

20:11.800 --> 20:12.860
It's from 1975.

20:12.860 --> 20:15.680
It's a year older than I am, and it's still being used.

20:16.580 --> 20:19.120
Again, very trivial to capture.

20:19.120 --> 20:20.060
Pull the reader off the wall.

20:20.060 --> 20:21.540
Attach one of these devices on there.

20:21.540 --> 20:25.180
It'll send it to you over Wi-Fi while you're outside the property.

20:25.360 --> 20:31.060
The fix here is tamper switches and OSDP, which is the Open Supervised Device Protocol.

20:31.060 --> 20:32.660
It's from 2015.

20:32.660 --> 20:33.860
It has encryption.

20:33.860 --> 20:38.400
You have to actually enroll your badge readers so that they communicate over an encrypted protocol.

20:38.480 --> 20:40.380
Again, it's RS-485.

20:40.380 --> 20:42.180
You can daisy-chain readers.

20:42.320 --> 20:43.040
Please don't.

20:43.040 --> 20:46.840
There's only very specific circumstances where you're going to want to do something like that.

20:46.920 --> 20:48.520
It's not perfect.

20:48.600 --> 20:52.040
There is a compromise possible while you're doing the reader pairing.

20:52.080 --> 20:57.240
If somebody on the other side has a... it's one of those, like, unlikely ones.

20:57.300 --> 21:03.580
But the biggest problem is 84% of installers, as of a couple years ago, never or seldom use it.

21:03.580 --> 21:05.720
They're still using the old Wiegand.

21:07.180 --> 21:09.260
So what else should I do?

21:09.260 --> 21:11.120
Test your readers regularly.

21:11.260 --> 21:13.960
Make sure that those are working correctly.

21:14.420 --> 21:15.940
Set up alerts in your system.

21:15.940 --> 21:22.400
It does you no good to spend all this money on an access control system if it generates alerts that go nowhere.

21:22.460 --> 21:23.400
Have it send an email.

21:23.400 --> 21:30.520
If you can't have a guard or somebody responsible for that, just have it send email alerts to a bunch of people and somebody can go check the door.

21:30.820 --> 21:32.140
These systems are really cool.

21:32.140 --> 21:39.460
You can link them up with a camera system so that if something happens on a door, it can bring up a view of that exact camera.

21:39.460 --> 21:40.640
Like, do it.

21:40.640 --> 21:42.780
It's definitely worth it.

21:43.060 --> 21:49.660
Document not only, you know, where your badge readers are, but where those remote power supplies are, where the batteries are.

21:50.260 --> 21:55.820
Check those batteries after three to five years is usually when you replace them.

21:55.820 --> 21:57.700
They're typical UPS batteries.

21:57.700 --> 21:59.320
They're really cheap from Home Depot.

21:59.660 --> 22:05.280
If it's in a hot room, then check them every, you know, replace them every three years.

22:05.280 --> 22:07.740
If it's in an air conditioned room, replace them every five years.

22:08.060 --> 22:11.900
And then I haven't gone into any bypasses, but there's lots of that stuff.

22:11.900 --> 22:13.400
So come to the physical security village.

22:13.400 --> 22:18.800
We've got all kinds of demos set up there for you to take a look at.

22:19.060 --> 22:21.120
I have an RFP on my GitHub.

22:21.120 --> 22:22.900
This RFP has everything.

22:23.220 --> 22:24.400
So feel free to look at it.

22:24.400 --> 22:38.060
Pick and choose the stuff that's important to you to put in your RFP or to talk to your project manager about to build the system the way that you think it should be built.

22:38.060 --> 22:41.820
But don't accept the defaults, because the defaults are never good.

22:42.720 --> 22:43.580
Thank you so much.

22:43.580 --> 22:44.780
I really appreciate it.
