    "id": "CVE-2020-10611",
    "published": "2020-04-15 19:15:13",
    "last_modified": "2026-06-17 02:48:05",
    "cvss_score": "9.8",
    "cvss_severity": "CRITICAL",
    "cvss_version": "3.1",
    "cvss_vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
    "cwe": "CWE-843",
    "description": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.",
    "epss_score": "0.05226",
    "epss_percentile": "0.92296",
    "kev": 0,
    "kev_due": null,
    "has_exploit": 0,
    "updated_at": "2026-10-07 18:17:21",
    "priority": {
        "rank": 3,
        "label": "In your normal cycle",
        "why": "Critical by CVSS (9.8), but no sign of active exploitation."
    },
    "products": [
        {
            "vendor": "trianglemicroworks",
            "product": "scada_data_gateway"
        }
    ],
    "kev_detail": null,
    "exploits": [],
    "refs_list": [
        "https://www.us-cert.gov/ics/advisories/icsa-20-105-03",
        "https://www.zerodayinitiative.com/advisories/ZDI-20-549/",
        "https://www.us-cert.gov/ics/advisories/icsa-20-105-03",
        "https://www.zerodayinitiative.com/advisories/ZDI-20-549/"
    ]
}