peter bassill · operator
$ cve CVE-2011-1567 JSON

CVE-2011-1567 EXPLOIT

10.0
HIGH · CVSS 2.0 · EPSS 69.6% (pctl 99)

Patch early

A public exploit exists.

Description

Multiple stack-based buffer overflows in IGSSdataServer.exe 9.00.00.11063 and earlier in 7-Technologies Interactive Graphical SCADA System (IGSS) allow remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via crafted (1) ListAll, (2) Write File, (3) ReadFile, (4) Delete, (5) RenameFile, and (6) FileInfo commands in an 0xd opcode; (7) the Add, (8) ReadFile, (9) Write File, (10) Rename, (11) Delete, and (12) Add commands in an RMS report templates (0x7) opcode; and (13) 0x4 command in an STDREP request (0x8) opcode to TCP port 12401.

Scoring

CVSS10.0 (HIGH, v2.0)
VectorAV:N/AC:L/Au:N/C:C/I:C/A:C
EPSS69.62% — more likely to be exploited than 99% of all CVEs
WeaknessCWE-119
On CISA KEVno
Public exploityes
Published2011-04-05
Last modified2026-06-16

Affected (1)

VendorProduct
7tigss

Public exploits

References

→ the Explorer  ·  watch your stack  ·  NVD