CVE-2018-18995
9.8
CRITICAL · CVSS 3.0 · EPSS 2.6% (pctl 85)
In your normal cycle
Critical by CVSS (9.8), but no sign of active exploitation.
Description
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
Scoring
| CVSS | 9.8 (CRITICAL, v3.0) |
|---|---|
| Vector | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| EPSS | 2.65% — more likely to be exploited than 85% of all CVEs |
| Weakness | CWE-306 |
| On CISA KEV | no |
| Public exploit | none known |
| Published | 2019-01-03 |
| Last modified | 2026-06-17 |
Affected (4)
| Vendor | Product |
|---|---|
| abb | gate-e1 |
| abb | gate-e1 firmware |
| abb | gate-e2 |
| abb | gate-e2 firmware |
References
→ the Explorer · watch your stack · NVD