peter bassill · operator
$ cve CVE-2018-19616 JSON

CVE-2018-19616 EXPLOIT

8.1
HIGH · CVSS 3.0 · EPSS 30.3% (pctl 98)

Patch early

A public exploit exists.

Description

An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.

Scoring

CVSS8.1 (HIGH, v3.0)
VectorCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS30.3% — more likely to be exploited than 98% of all CVEs
WeaknessCWE-287
On CISA KEVno
Public exploityes
Published2018-12-26
Last modified2026-06-17

Affected (2)

VendorProduct
rockwellautomationpowermonitor 1000
rockwellautomationpowermonitor 1000 firmware

Public exploits

References

→ the Explorer  ·  watch your stack  ·  NVD