CVE-2020-12834

9.8
CRITICAL · CVSS 3.1 · EPSS 11.1% (pctl 96)

Patch early

EPSS 11.1% — above the 10% action threshold.

Description

eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).

Scoring

CVSS9.8 (CRITICAL, v3.1)
VectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS11.07% — more likely to be exploited than 96% of all CVEs
WeaknessCWE-276
On CISA KEVno
Public exploitnone known
Published2020-05-15
Last modified2026-06-17

Affected (4)

VendorProduct
eq-3ccu3 firmware
eq-3homematic ccu2
eq-3homematic ccu2 firmware
eq-3homematic ccu3